CDS
VAN
B8
Copyright by Brähler ICS
23
Troubleshooting table
Error description
Error cause
Error solution
No remote control via B8 Control
software module
Device ID is not proper set.
MIDI Data is not connected to the
right I/O pad (EDAT/ADAT
®
).
Check the device ID of the B8 unit
(Dip switches 1-5 at the backside).
Make sure, you’ve set the
corresponding ID 0-31 in the B8
control module.
Make sure, you’ve connected the
MIDI cable in the software to the
right output pad.
Make sure you’ve typed in the right
ID number into the B8 control
module.
No audio or very low signal
Microphone level signal connected to
line level input channel.
Check the input settings for this
channel at the B8 control module
(Mic/Line)
Cracks and distortion on the audio
input signal.
Input signal too high.
Check the Peak LED at the front side
of the B8. Lower the pre-
amplification with the corresponding
rotary knob on the B8 control
module.
No audio signals on the (or one)
output channel(s).
B8 is not terminated correctly.
Incorrect audio routing within the
CDSVAN environment.
Check the DIP switch 11 or check
the appropriate terminator at the
LINK socket of the 2
nd
B8.
Check the audio routing within the
CDSVAN environment.
Содержание CDSVAN
Страница 1: ...Operating instructions Rev 3 80 CDSVAN Digital Conference Management System B8 AD DA Interface ...
Страница 4: ...B8 CDSVAN 4 Copyright by Brähler ICS ...
Страница 12: ...B8 CDSVAN 12 Copyright by Brähler ICS All components are described on the following pages ...
Страница 24: ...B8 CDSVAN 24 Copyright by Brähler ICS ...
Страница 26: ...B8 CDSVAN 26 Copyright by Brähler ICS ...
Страница 28: ...B8 CDSVAN 28 Copyright by Brähler ICS ...
Страница 30: ...B8 CDSVAN Notes ...
Страница 32: ...Phone 49 0 2244 930 0 www braehler com 07 0250 ...