CDS
VAN
B8
Copyright by Brähler ICS
13
DIP Switch Settings
Some basic settings have to be done at the rear side of each B8 unit within the system. Besides the cabling
of each audio patch cable to the desired in- and outputs, you can choose some working modes the B8 offers
to match the system requirements:
Each DIP switch has two positions:
OFF
- switched to the upper position
ON
– switched to the lower position
DIP Switches:
Device ID
(Word) Clock mode
Slave sync(hronisation)
Masterclock
AF control via
Cable Length
Termination
Ground to Earth
Device ID
Switches 1
– 5.
The B8 needs to have a unique ID number to be identified by the CDSVAN system.
This ID is used by the B8 Control Module to identify the corresponding B8. Double numbers force the units to
behave the same, when connected to the control device (see below).
The ID can range between 0 and 31.
Please make the corresponding settings to the first 5 switches in binary format.
Example:
B8 No. 0 - switches 1
– 5 OFF
B8 No. 1 - switches 1 ON and 2
– 5 OFF
B8 No. 2 - switches 1 OFF and 2 ON and 3
– 5 OFF
B8 No. 3 - switches 1 and 2 ON and 3
– 5 OFF
B8 No. 4 - switches 1 and 2 OFF and 3 ON and 4
– 5 OFF …
B8 No. 31 - switches 1
– 5 ON
If no B8 control is connected, it will work with its default settings: Line level on all channels.
The ID’s are independent of the positioning in the system of the B8 units.
Содержание CDSVAN
Страница 1: ...Operating instructions Rev 3 80 CDSVAN Digital Conference Management System B8 AD DA Interface ...
Страница 4: ...B8 CDSVAN 4 Copyright by Brähler ICS ...
Страница 12: ...B8 CDSVAN 12 Copyright by Brähler ICS All components are described on the following pages ...
Страница 24: ...B8 CDSVAN 24 Copyright by Brähler ICS ...
Страница 26: ...B8 CDSVAN 26 Copyright by Brähler ICS ...
Страница 28: ...B8 CDSVAN 28 Copyright by Brähler ICS ...
Страница 30: ...B8 CDSVAN Notes ...
Страница 32: ...Phone 49 0 2244 930 0 www braehler com 07 0250 ...