16
ILL1288-A
Plug
CABLE INSTALLATION
NOTE! Leave the electronics module safely in the tank, as the motor
plug will require connection to the underside of the module when the
venturi is refitted into the Cooler.
WARNING: Do not let cables, cable ends, or the control box get wet.
After fitting the cooler to the dropper, disconnect the electronics module from
the tank by removing the screw under the switch as shown (Fig 15). The
isolation switch cannot be activated with this screw removed. Place the
electronics module and the screw to one side in the tank.
Your installation kit includes the power cord and thermostat cable. Drop the
power cord plug end along with the taped end of the thermostat cable into
the dropper duct. Route the power cord socket end with the thermostat
cable upwards through the corner hole in the transition and out the tank
cavity as shown. Lock the power cord socket in place by sliding the plug in
sideways as shown.
The plug will only insert one way, with the chamfered end first (Fig 16). For
now, leave the thermostat cable end in the tank as it will be connected later.
Position the cords in the dropper so they will be accessible from inside the
roof space.
Pass the cords through the grommet in the dropper.
Do not coil the excess length of the power cord. Place excess length of the
thermostat cable in the roof cavity and not inside the cooler or dropper.
Push the cables into the cable slot in the transition as shown (thermostat
cable first) and then seal the hole with the plug provided.
IMPORTANT
Test the weatherdamper operation and ensure that the cables in the
dropper do not interfere with the operation of the weatherdamper.
8
®
CPL CPS LCB BM Evaporative Cooler
®
CPMD equipped EVAPORATIVE
COOLER
BRAEMAR SCC
SPECTROLINK
HEATER CONTROLLER
BRAEMAR GAS HEATER
The SCC must be set to “COOL
1"
to operate an evaporative cooler
CPMD
BSC
SCC
CPMD COMM
’
S LOOM
SCC COMM
’
S LOOM
Heater
power
supply
To
“
CC
”
terminal labelled
“
Spectrolink Multi Zone
”
on BSC
Cooler
power
supply
To
“
CPMD
”
terminal labelled
“
To EVAP Control
”
on BSC
ILL1478-A
CONNECTING THE COOLER TO A BRAEMAR SPECTROLINK GAS
HEATER CONTROLLER
This cooler can be inter-connected to a Braemar Gas Heater and operated
from the Braemar SCC Spectrolink Heater controller. Any Seeley
International evaporative cooler equipped with a CPMD Electronic Module
can be operated this way. The following diagram (Fig 17) shows the
connections required:
17