Compressor Protection

This thermostat includes an automatic compressor protection feature to avoid 
potential damage to the cooling system from short cycling. This thermostat 
automatically provides a 5-minute delay after turning off the cooling system 
output to protect the compressor. This protection is also present in the heat mode 
of operation on single stage heat pump systems to protect the compressor.

NOTE:

  

The installer can reset the thermostat and bypass the compressor 

protection features by pressing the 

RESET 

button. This will erase all entered 

programs, current time of day, day of week and other user settings and should 

only be used during installation for testing purposes or to reset a thermostat 

to regain normal operation. This will return all thermostat settings to their 

default values.

Low Battery Detection

This thermostat requires two (2) new, 
properly installed “AA” Alkaline batteries
to maintain the system clock and to provide 
proper thermostat power when 24 volt AC 
power fails or is not connected to the
thermostat. When the batteries start to become 
too weak to provide proper operation, the 
thermostat will begin to display a low battery indicator.

The low battery indicator is provided to inform the user when the batteries 
require immediate attention. We recommend replacing the batteries as soon 
as the low battery indicator appears. If the batteries are not replaced after 
the low battery indicator first appears, the thermostat may not provide 
proper heating or cooling system operation. 

Even if the low battery indicator does not appear, the batteries should be replaced 
at least once a year, or if you plan on leaving the premises for over a month.  
This thermostat can be powered from 24 volts AC or battery power. To determine 
if 24 volt AC power is connected to the thermostat, refer to the installation and 
wiring diagram section. If you cannot determine how this thermostat is powered, 
call a professional service technician to determine the type of installation and the 
proper operation of your system.

 

Resetting the Thermostat

The Reset feature allows the user to completely reset the thermostat to register 
new manual switch settings. To erase all entered programs, current time of day, 
day of week and other user settings, gently press the 

RESET

 button using a paper 

clip or a small pencil tip. This will return all thermostat settings to their default 
values and register all new manual switch settings for proper operation.

Non-Volatile Memory

In the event of a power failure, the Non-Volatile Memory feature allows all 
settings to be recovered, eliminating the need to reset temperature and 
differential settings. When AC power is restored after an outage, all settings are 
retrieved from memory and reinstated.

Status Indicators
HEAT:  

This will turn on whenever the 

   

 system switch is in the HEAT mode. 

   

 “HEAT” will flash when the heating 

   

 system is running.

COOL

:  This will turn on whenever the 

   

 system switch is in the cool mode. 

   

 “COOL” will flash when the cooling 

   

 system is running.

Replacing the Batteries

1.

 Open the thermostat cover and locate the battery compartment door.

2.

 Remove the two "AA" alkaline batteries located in the battery compartment.  

3.

 Install two new "AA" alkaline batteries into battery compartment. Make sure to   

  match the positive (+) ends of the batteries with the positive (+) terminals  

 

  located in the battery compartment.

4.

 Close battery compartment and verify that the low battery indicator does not 

  appear in the display.

cont.

Additional Operation Features

7

cont.

Additional Operation Features

7

COOL

Battery Replacement

8

12

13

Содержание Premier 5000

Страница 1: ...thermostat This thermostat should only be used as described in this manual Any other use is not recommended and will void the warranty Specifications Installation Testing Your New Thermostat Programming User Settings Setting Your Energy Saving Program Temperature Adjustment Additional Operation Features Battery Replacement Troubleshooting Wiring Diagrams 1 2 3 4 5 6 7 8 9 10 1 Specifications MODEL...

Страница 2: ...rand of the old thermostat your letters may be different 4 After labeling the old wires loosen each connection and remove them from old sub base Secure the wires to prevent them from slipping into the hole in the wall 5 Remove the old sub base from the wall again being careful that the wires do not slip into the hole in the wall 6 Use the chart below to determine the new thermostat connections As ...

Страница 3: ...the quick wiring terminal blocks Use the wiring diagram chart to insure the old and new connections are correct 9 To prevent electrical shorts and potential damage to the thermostat make sure all wire connections are secure and not touching each other 10 Turn the thermostat body over exposing the rear view of the circuit board 11 Locate the internal F C switch on the circuit board Using your finge...

Страница 4: ... The cooling system should stop within a few seconds 7 Place the fan switch in the ON position The system blower should start 8 Place the fan switch in the AUTO position The system blower should stop Installation 2 cont Do not short or jumper across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation This could damage the thermostat and ...

Страница 5: ...k 7 Press the DAY TIME button again and the thermostat will return to normal operating mode NOTE The thermostat will return to normal operating mode automatically after 30 seconds if no key is pressed It will also return to normal operating mode immediately if the RETURN button is pressed Function Status After Reset Operation Mode Normal Operating Mode Temperature Hold Extended and Temporary Hold ...

Страница 6: ...ically return to the normal operation mode Otherwise you can press the RETURN button again to set the Residual Cooling Fan Delay When you go directly to the next programming step it is not necessary to press and hold RETURN for 4 seconds Setting Residual Cooling Fan Delay The default setting is 60 seconds During the COOL mode of operation the fan will stay on for 60 seconds after the set point tem...

Страница 7: ...e last warning 2 Press the or button to change the Filter Monitor interval to the desired value of 0 disabled 30 60 90 120 or 180 days Press the RETURN button again to set adaptive recovery mode or wait 30 seconds for the thermostat to return to normal mode Setting Adaptive Recovery Mode ARM see section 7 The default setting is OFF Adaptive Recovery Mode disabled 1 In normal operating mode press a...

Страница 8: ...n the OFF mode the display will indicate OFF NOTE For 7 day programming the defaults follow the Weekday programming shown above To change between 5 2 and 7 day programming adjust switch by following step 14 of Installation section Entering Your Program 5 2 Day Mode The 5 2 Day mode has separate Weekday and Weekend Program Groups that allow you to change the daily set point times and temperatures t...

Страница 9: ...ow steps 3 through 6 to set the set point time and temperatures for the periods of MORN DAY EVE and NIGHT 9 Place the system switch in the COOL mode of operation The display will show COOL Follow steps 2 through 8 to program the set point times and tempera tures for the Weekday and Weekend groups in the COOL mode NOTE To erase all entered programs current time of day day of week and other user set...

Страница 10: ...ndicator will be flashing 3 If you wish to program each day individually press the DAY TIME button to select a specific day 4 Press the or button to change the time to the desired hour in one hour increments Press the PROG button The minute portion of the set point time will begin flashing 5 Press the or button to change the time to the desired minute in 10 minute increments Press the PROG button ...

Страница 11: ...e is in effect The Temporary Program Override will reset when the next set point time occurs or after four hours whichever comes first Extended Hold Vacation Mode 1 Press the HOLD button to bypass the program schedule The current set point temperature will be held either permanently or for 24 hours depending on the setting selection made in section 4 2 Press the HOLD button again to return the the...

Страница 12: ...recovering room temperature from setback programs to comfort programs so it will only take place when the current heating program set point temperature is lower than the upcoming program set point temperature or the current cooling program set point temperature is higher than the upcoming program set point temperature During ARM room temperature is recovered gradually by turning on the heating or ...

Страница 13: ...d to provide proper thermostat power when 24 volt AC power fails or is not connected to the thermostat When the batteries start to become too weak to provide proper operation the thermostat will begin to display a low battery indicator The low battery indicator is provided to inform the user when the batteries require immediate attention We recommend replacing the batteries as soon as the low batt...

Страница 14: ... an outage all settings are retrieved from memory and reinstated Status Indicators HEAT This will turn on whenever the system switch is in the HEAT mode HEAT will flash when the heating system is running COOL This will turn on whenever the system switch is in the cool mode COOL will flash when the cooling system is running Replacing the Batteries 1 Open the thermostat cover and locate the battery ...

Страница 15: ... cooling or cooling instead of heating Potential Solution Check thermostat wiring to make sure that the heating and cooling stages are connected to the correct terminals on the wiring terminal block See section 10 Symptom Thermostat will not follow program set points Potential Solutions Check current time of day day of week program settings Make sure to verify AM PM indicator is accurately display...

Страница 16: ...re setting range of 45 to 90 F 7 to 32 C Symptom Cannot program a set point temperature lower than 45 F 7 C Potential Solution This is below the normal thermostat temperature setting range of 45 to 90 F 7 to 32 C Symptom Thermostat will not allow set point changes Potential Solution The Keypad is locked Press the and key together at the same time for one second to unlock See section 7 Symptom Fan ...

Страница 17: ...quired for battery only operation of thermostat 2 For heating or cooling only system ignore opposite connection 3 For 2 wire 24 Volt AC or 250mV 750mV millivolt heating systems ignore cooling connection and fan control Single Stage Heat Pump System NOTE 1 Transformer Common not required for battery only operation of thermostat 2 For units requiring reversing valve to be energized during heating co...

Страница 18: ...eturned postage prepaid to our warranty facility in a padded carton within the warranty period with proof of the original date of purchase and a brief description of the malfunction This limited warranty does not include the cost of removal or re installation This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province Answe...

Отзывы: