10
Temperature Adjustment
6
Review Set Temperature
1.
Press and hold the or button. The
current set point temperature will be
displayed in place of the current room
temperature, and the indicator
SET
will
be displayed.
2.
The display will return to normal operating
mode when the or button is released.
Continuing to hold the or button for 1 second or longer will allow the user
to temporarily override the current programmed set point.
Temporary Program Override
1.
Press and hold or button for 1 second
or longer. The entire display will flash
once and the
SET
indicator will be
displayed. Release the or button and
press the or button again as desired
to adjust the set temperature.
2.
The display will return to normal operating
mode after 15 seconds or you can press the
RETURN
button.
3.
The program indicator (
MORN, DAY, EVE
or
NIGHT
) will be flashing in the display,
indicating that a Temporary Program Override is in effect. The Temporary Program
Override will reset when the next set point time occurs or after four hours–
whichever comes first.
Extended Hold (Vacation) Mode
1.
Press the
HOLD
button to bypass the
program schedule. The current set point
temperature will be held either
permanently or for 24 hours, depending
on the setting selection made in section 4.
2.
Press the
HOLD
button again to return the
thermostat to the normal program operation.
3.
The hold period will last until the hold is released as in step number 2 above,
or is limited to 24 hours if the default was changed in the User Options Settings
(see section 4).
Filter Check Monitor
(see section 4)
The Filter Check Monitor displays a reminder
for required filter replacement or cleaning by
flashing the
FILT
segment in the display. See
instructions on your filter or heating/cooling
unit for recommendations for interval setting.
When the selected interval has been reached,
and required cleaning or replacement has
been performed, press the
RETURN
button in any normal mode to reset the timer
and turn off the warning.
cont.
Additional Operation Features
7
Locking the Keypad
To prevent accidental or undesired
adjustment of the thermostat, the Keypad
Lockout feature disables the operation of
the keypad except for the backlight key. In
order to lock the keypad, press and hold
both the and buttons together at the
same time for 5 seconds. The
LOCK
segment in the display will flash once per second, and then appear continuously
in the display. The keypad is now locked. To unlock the keypad, press and hold
the and buttons together at the same time for 1 second. The
LOCK
segment
will disappear and the keypad will become unlocked.
Adaptive Recovery Mode (ARM™)
(see section 4)
In order to maximize comfort and energy efficiency, this thermostat is equipped
with an Adaptive Recovery Mode (ARM™). This feature minimizes the amount of
time required by heating or cooling system to reach the new set point, after a
setback period is completed, and assures your desired temperature is achieved
at your set program times.
This feature activates when recovering room temperature from setback programs
to comfort programs, so it will only take place when the current (heating)
program set point temperature is lower than the upcoming program set point
temperature, or the current (cooling) program set point temperature is higher
than the upcoming program set point temperature.
During ARM™, room temperature is recovered gradually by turning on the
heating or cooling before the end of the setback period. The set point temperature
is changed to that of the upcoming comfort program temperature. The start time
of recovery is based on the difference between the current room temperature and
the upcoming comfort program set point temperature. The recovery to the
upcoming set point starts 10 to 15 minutes before the upcoming set point time
for each degree of temperature change required, up to a maximum of 2 hours in
the HEAT mode, 3 hours in the COOL mode.
ARM™ does not operate when the unit is in HOLD mode, or if the program is
temporarily overridden.
11
Additional Operation Features
7
Circulating Fan Mode–Fan Operation
AUTO:
Fan operates as required by heating or cooling system.
:
When heating or cooling is not active, fan will run as needed to ensure
a 35% minimum run time.
ON:
Fan will run at all times.
®