10

Temperature Adjustment

6

Review Set Temperature
1.

 Press and hold the    or    button. The 

  current set point temperature will be  

 

  displayed in place of the current room 
  temperature, and the indicator 

SET

 will 

  be displayed.

2.

 The display will return to normal operating 

  mode when the    or    button is released. 
  Continuing to hold the    or    button for 1 second or longer will allow the user 
  to temporarily override the current programmed set point.

Temporary Program Override
1.

 Press and hold    or    button for 1 second 

  or longer. The entire display will flash  

 

  once and the 

SET

 indicator will be 

  displayed. Release the    or    button and  

 

  press the    or    button again as desired 
  to adjust the set temperature.

2.

 The display will return to normal operating 

  mode after 15 seconds or you can press the 

RETURN

 button.

3.

 The program indicator (

MORN, DAY, EVE 

or

 NIGHT

) will be flashing in the display,   

  indicating that a Temporary Program Override is in effect. The Temporary Program    
  Override will reset when the next set point time occurs or after four hours–
  whichever comes first.

Extended Hold (Vacation) Mode
1.

 Press the 

HOLD

 button to bypass the 

  program schedule. The current set point  

 

  temperature will be held either 
  permanently or for 24 hours, depending 
  on the setting selection made in section 4.

2.

 Press the 

HOLD

 button again to return the 

  thermostat to the normal program operation.

3.

 The hold period will last until the hold is released as in step number 2 above,    

  or is limited to 24 hours if the default was changed in the User Options Settings 
  (see section 4). 

Filter Check Monitor

 (see section 4)

The Filter Check Monitor displays a reminder 
for required filter replacement or cleaning by 
flashing the 

FILT

 segment in the display. See 

instructions on your filter or heating/cooling 
unit for recommendations for interval setting. 
When the selected interval has been reached, 
and required cleaning or replacement has 
been performed, press the 

RETURN

 button in any normal mode to reset the timer 

and turn off the warning.

cont.

Additional Operation Features

7

Locking the Keypad

To prevent accidental or undesired 
adjustment of the thermostat, the Keypad 
Lockout feature disables the operation of 
the keypad except for the backlight key. In 
order to lock the keypad, press and hold 
both the    and    buttons together at the 
same time for 5 seconds. The 

LOCK

 

segment in the display will flash once per second, and then appear continuously 
in the display. The keypad is now locked. To unlock the keypad, press and hold 
the    and    buttons together at the same time for 1 second. The 

LOCK 

segment 

will disappear and the keypad will become unlocked.

Adaptive Recovery Mode (ARM™) 

(see section 4)

In order to maximize comfort and energy efficiency, this thermostat is equipped 
with an Adaptive Recovery Mode (ARM™). This feature minimizes the amount of 
time required by heating or cooling system to reach the new set point, after a 
setback period is completed, and assures your desired temperature is achieved 
at your set program times. 
This feature activates when recovering room temperature from setback programs 
to comfort programs, so it will only take place when the current (heating) 
program set point temperature is lower than the upcoming program set point 
temperature, or the current (cooling) program set point temperature is higher 
than the upcoming program set point temperature.
During ARM™, room temperature is recovered gradually by turning on the 
heating or cooling before the end of the setback period. The set point temperature 
is changed to that of the upcoming comfort program temperature. The start time 
of recovery is based on the difference between the current room temperature and 
the upcoming comfort program set point temperature. The recovery to the 
upcoming set point starts 10 to 15 minutes before the upcoming set point time 
for each degree of temperature change required, up to a maximum of 2 hours in 
the HEAT mode, 3 hours in the COOL mode. 
ARM™ does not operate when the unit is in HOLD mode, or if the program is 
temporarily overridden.

11

Additional Operation Features

7

Circulating Fan Mode–Fan Operation

AUTO: 

Fan operates as required by heating or cooling system.

      :

 

When heating or cooling is not active, fan will run as needed to ensure    

   

a 35% minimum run time.

ON:

  

Fan will run at all times.

®

Содержание Premier 5000

Страница 1: ...thermostat This thermostat should only be used as described in this manual Any other use is not recommended and will void the warranty Specifications Installation Testing Your New Thermostat Programming User Settings Setting Your Energy Saving Program Temperature Adjustment Additional Operation Features Battery Replacement Troubleshooting Wiring Diagrams 1 2 3 4 5 6 7 8 9 10 1 Specifications MODEL...

Страница 2: ...rand of the old thermostat your letters may be different 4 After labeling the old wires loosen each connection and remove them from old sub base Secure the wires to prevent them from slipping into the hole in the wall 5 Remove the old sub base from the wall again being careful that the wires do not slip into the hole in the wall 6 Use the chart below to determine the new thermostat connections As ...

Страница 3: ...the quick wiring terminal blocks Use the wiring diagram chart to insure the old and new connections are correct 9 To prevent electrical shorts and potential damage to the thermostat make sure all wire connections are secure and not touching each other 10 Turn the thermostat body over exposing the rear view of the circuit board 11 Locate the internal F C switch on the circuit board Using your finge...

Страница 4: ... The cooling system should stop within a few seconds 7 Place the fan switch in the ON position The system blower should start 8 Place the fan switch in the AUTO position The system blower should stop Installation 2 cont Do not short or jumper across terminals on the gas valve or at the heating or cooling system control board to test the thermostat installation This could damage the thermostat and ...

Страница 5: ...k 7 Press the DAY TIME button again and the thermostat will return to normal operating mode NOTE The thermostat will return to normal operating mode automatically after 30 seconds if no key is pressed It will also return to normal operating mode immediately if the RETURN button is pressed Function Status After Reset Operation Mode Normal Operating Mode Temperature Hold Extended and Temporary Hold ...

Страница 6: ...ically return to the normal operation mode Otherwise you can press the RETURN button again to set the Residual Cooling Fan Delay When you go directly to the next programming step it is not necessary to press and hold RETURN for 4 seconds Setting Residual Cooling Fan Delay The default setting is 60 seconds During the COOL mode of operation the fan will stay on for 60 seconds after the set point tem...

Страница 7: ...e last warning 2 Press the or button to change the Filter Monitor interval to the desired value of 0 disabled 30 60 90 120 or 180 days Press the RETURN button again to set adaptive recovery mode or wait 30 seconds for the thermostat to return to normal mode Setting Adaptive Recovery Mode ARM see section 7 The default setting is OFF Adaptive Recovery Mode disabled 1 In normal operating mode press a...

Страница 8: ...n the OFF mode the display will indicate OFF NOTE For 7 day programming the defaults follow the Weekday programming shown above To change between 5 2 and 7 day programming adjust switch by following step 14 of Installation section Entering Your Program 5 2 Day Mode The 5 2 Day mode has separate Weekday and Weekend Program Groups that allow you to change the daily set point times and temperatures t...

Страница 9: ...ow steps 3 through 6 to set the set point time and temperatures for the periods of MORN DAY EVE and NIGHT 9 Place the system switch in the COOL mode of operation The display will show COOL Follow steps 2 through 8 to program the set point times and tempera tures for the Weekday and Weekend groups in the COOL mode NOTE To erase all entered programs current time of day day of week and other user set...

Страница 10: ...ndicator will be flashing 3 If you wish to program each day individually press the DAY TIME button to select a specific day 4 Press the or button to change the time to the desired hour in one hour increments Press the PROG button The minute portion of the set point time will begin flashing 5 Press the or button to change the time to the desired minute in 10 minute increments Press the PROG button ...

Страница 11: ...e is in effect The Temporary Program Override will reset when the next set point time occurs or after four hours whichever comes first Extended Hold Vacation Mode 1 Press the HOLD button to bypass the program schedule The current set point temperature will be held either permanently or for 24 hours depending on the setting selection made in section 4 2 Press the HOLD button again to return the the...

Страница 12: ...recovering room temperature from setback programs to comfort programs so it will only take place when the current heating program set point temperature is lower than the upcoming program set point temperature or the current cooling program set point temperature is higher than the upcoming program set point temperature During ARM room temperature is recovered gradually by turning on the heating or ...

Страница 13: ...d to provide proper thermostat power when 24 volt AC power fails or is not connected to the thermostat When the batteries start to become too weak to provide proper operation the thermostat will begin to display a low battery indicator The low battery indicator is provided to inform the user when the batteries require immediate attention We recommend replacing the batteries as soon as the low batt...

Страница 14: ... an outage all settings are retrieved from memory and reinstated Status Indicators HEAT This will turn on whenever the system switch is in the HEAT mode HEAT will flash when the heating system is running COOL This will turn on whenever the system switch is in the cool mode COOL will flash when the cooling system is running Replacing the Batteries 1 Open the thermostat cover and locate the battery ...

Страница 15: ... cooling or cooling instead of heating Potential Solution Check thermostat wiring to make sure that the heating and cooling stages are connected to the correct terminals on the wiring terminal block See section 10 Symptom Thermostat will not follow program set points Potential Solutions Check current time of day day of week program settings Make sure to verify AM PM indicator is accurately display...

Страница 16: ...re setting range of 45 to 90 F 7 to 32 C Symptom Cannot program a set point temperature lower than 45 F 7 C Potential Solution This is below the normal thermostat temperature setting range of 45 to 90 F 7 to 32 C Symptom Thermostat will not allow set point changes Potential Solution The Keypad is locked Press the and key together at the same time for one second to unlock See section 7 Symptom Fan ...

Страница 17: ...quired for battery only operation of thermostat 2 For heating or cooling only system ignore opposite connection 3 For 2 wire 24 Volt AC or 250mV 750mV millivolt heating systems ignore cooling connection and fan control Single Stage Heat Pump System NOTE 1 Transformer Common not required for battery only operation of thermostat 2 For units requiring reversing valve to be energized during heating co...

Страница 18: ...eturned postage prepaid to our warranty facility in a padded carton within the warranty period with proof of the original date of purchase and a brief description of the malfunction This limited warranty does not include the cost of removal or re installation This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province Answe...