Detailed Explanation of User Options: 

Temperature Differential

(User Option 1 and 2)

The differential setting is the temperature control range that your thermostat 
will provide. The smaller the setting, the tighter your range of temperature 
control and comfort will be. The 2nd stage differential is only for systems 
with a second stage of heating (auxiliary heat).

Temperature Adjustment

Press the     or     button to adjust the current set point temperature.

Status Indicators

Status indicators appear in the display to let you 
know if your system is heating, cooling or off.

HEAT 

If flashing, indicates your heating system 

   

is running.

COOL  

If flashing,

 

indicates your cooling system 

   

is running.

Additional Status Indicators (Model 1200NC Only):

AUX  

Indicates that the auxiliary stage of heating is running           

   

(Multi-Stage Systems only), or that the emergency heat

   

system is running (heat pump systems only).

Resetting the Thermostat

This thermostat provides you with a reset button that will erase all of your 
user settings. 
To reset the thermostat, use a small object such as a tooth pick or paper-
clip and gently press the button located inside the small hole on the front of 
the thermostat housing labeled “reset”.

7

Additional Operation Features

Compressor Protection

This thermostat includes an automatic compressor protection delay to 
avoid potential damage to your system from short cycling. This feature 
activates a short delay after turning off the system compressor. 

8

Thermostat Maintenance

Changing the Batteries

Depending on your particular installation, this 
thermostat may be equipped with two (2) “AA”      
type alkaline batteries.

If batteries are installed and they become low, 
a low battery indicator will appear in the display. 

You should change your batteries immediately 
when you see the low battery signal by following 
these instructions.

Содержание Builder 1000NC

Страница 1: ...vice technicians only Follow applicable codes 1200NC Up to 2 Heat 1 Cool Conventional and Heat Pump Read all instructions before proceeding This thermostat is compatible with Single stage heat cool conventional and heat pump systems Conventional systems up to 2 heat 1 cool 1200NC only Single compressor heat pump systems with an auxiliary heat stage 1200NC only 250 750 millivolt heat only systems E...

Страница 2: ...sunlight appliances concealed pipes chimneys and outside walls 2 3 4 5 8 7 9 6 1 Room Temperature Displays the current room temperature Arrow Buttons Used to increase or decrease settings System Switch Selects Heat Cool or Off Backlight Button Illuminates the display backlight Low Battery Indicator Indicates when the batteries need to be replaced System Status Indicator Displays information about ...

Страница 3: ...our desired location Use supplied anchors for drywall or plaster Provide Power For 24 Volt AC power you must connect the common side of the trans former to the C terminal on the thermostat sub base For primary or back up power insert the 2 supplied AA type alkaline batteries into the battery compartment located in the front of the thermostat near the bottom Make sure to position the Positive and N...

Страница 4: ...Emergency Heat Relay W2 Output 2nd Stage Heat Auxiliary Heat Additional Terminations 1200NC only Heat Only or Millivolt Set Installer Switch to NORM Rh Power Connection W Heat Relay appears as W1 E on 1200NC G Fan Relay note 4 C 24 Volt AC Transformer Common note 1 1 HEAT 1 COOL Single or Dual Transformer Set Installer Switch to NORM Rh 24 Volt AC Power heating transformer note 2 Rc 24 Volt AC Pow...

Страница 5: ...ntional Systems cont Typical Wiring Configurations NOTE The Installer Switch option will be configured in the next step Heat Pump Systems 1 HEAT 1 COOL No Auxiliary Heat Set Installer Switch to HP Rh 24 Volt AC Power Rc Connected to Rh with supplied Jumper Wire O or B Changeover Valve note 2 Y1 Compressor Relay appears as Y1 on 1200NC G Fan Relay C 24 Volt AC Transformer Common note 1 2 HEAT 1 COO...

Страница 6: ...s required NORM HP NORM F C F HE HG HG Set Installer Switches 4 NORM Select for conventional systems HP Select for heat pump systems F Select for fahrenheit temperature scale C Select for celsius temperature scale HG Select for gas heat HE Select for electric heat Attach Thermostat to Sub Base 5 1 Line up the thermostat body with the sub base 2 Carefully push the thermostat body against the sub ba...

Страница 7: ... 3 Move the SYSTEM switch to the OFF mode Allow the heating system to fully shut down 4 Move the SYSTEM switch to the COOL mode 5 Press to lower the set temperature a minimum of 3 degrees below the current room temperature The system should start within a few seconds unless compressor short cycle protection is active See note above 6 Move the SYSTEM switch to the OFF mode Allow the cooling system ...

Страница 8: ... heat 6 Operating Your Thermostat Setting the System Control Mode The System Control has several modes of operation that can be selected by moving the SYSTEM switch to one of three positions COOL Only your cooling system will operate OFF Heating and cooling systems are off HEAT Only your heating system will operate Additional Switch Position Model 1200NC Only EMER Operates a backup heat source Eme...

Страница 9: ...r settings To reset the thermostat use a small object such as a tooth pick or paper clip and gently press the button located inside the small hole on the front of the thermostat housing labeled reset 7 Additional Operation Features Compressor Protection This thermostat includes an automatic compressor protection delay to avoid potential damage to your system from short cycling This feature activat...

Страница 10: ...ical Assistance www braeburnonline com Call us toll free 866 268 5599 U S 630 844 1968 Outside the U S 2012 Braeburn Systems LLC All Rights Reserved Made in China Store this manual for future reference 1000NCW 100 12 Limited Warranty When installed by a professional contractor this product is backed by a 5 year limited warranty Limitations apply For limitations terms and conditions you may obtain ...

Страница 11: ......

Отзывы: