ACC
EAC
(HOT)
C
115v.
60CY.
ON-OFF SWITCH
COMMON LEAD
FURNACE
C
HI
LO
229050
CURRENT
SENSING
RELAY
MULTI
SPEED
BLOWER
MOTOR
24V. SOLENOID VALVE
HUMIDISTAT
24 V. TRANSFORMER
ACC
EAC
(HOT)
C
115v.
60CY.
ON-OFF SWITCH
24V. SOLENOID VALVE
24V. SOLENOID VALVE
24 V. TRANSFORMER
L1
C
NO
(HOT)
L2
115v.
60CY.
ON-OFF SWITCH
AIR PRESSURE
SWITCH
24 V. TRANSFORMER
HUM
FURNACE
CONTROL BOARD
C
24v.
60CY.
24V. SOLENOID VALVE
HUMIDISTAT
HUMIDISTAT
HUMIDISTAT
FURNACE
BOARD
Braeburn Systems LLC warrants each new Braeburn humidistat against any defects that are due to faulty material or workmanship for a period of one year after
the original date of purchase by a professional service technician. This warranty and our liability does not include damage to merchandise or the humidistat
resulting from accident, alteration, neglect, misuse, improper installation or any other failure to follow Braeburn installation and operating instructions.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn humidistat under warranty provided it is returned postage prepaid to our warranty
facility in a padded carton within the warranty period, with proof of the original date of purchase and a brief description of the malfunction. This limited warranty
does not include the cost of removal or re-installation.
This warranty gives you specific legal rights and you may also have other rights that vary from state to state or province to province. Answers to any questions
regarding our limited warranty may be obtained by writing our corporate offices.
LIMITED WARRANTY
ACC
EAC
HOT
MANUAL HUMIDISTAT
120 VAC WITH CONTROL FROM FURNACE BOARD
FURNACE
OR FAN
CONTROL
120 VAC
FURNACE
CONTROL
FIELD SUPPLIED
RECEPT & SWITCH
C
HUMIDIFIER
RED
POWER TO HUMIDISTAT
YELLOW
CONTROL
NOTE:
Red wires are for humidistat power if required.
DO NOT CONNECT RED WIRES TO ANOTHER POWER
SOURCE OR ONE ANOTHER. DOING SO WILL VOID WARRANTY.
NOTE:
Yellow wires are for Humidistat Control. DO NOT APPLY VOLTAGE
TO YELLOW WIRES. DOING SO WILL VOID WARRANTY.
CAP OFF -
DO NOT CONNECT
TOGETHER
HUMIDISTAT
HOT
MANUAL HUMIDISTAT
120 VAC WITH CURRENT SENSING RELAY
FIELD SUPPLIED
RECEPT & SWITCH
C
HUMIDIFIER
RED
POWER TO HUMIDISTAT
YELLOW
NOTE:
Red wires are for humidistat power if required.
DO NOT CONNECT RED WIRES TO ANOTHER POWER
SOURCE OR ONE ANOTHER. DOING SO WILL VOID WARRANTY.
NOTE:
Yellow wires are for Humidistat Control. DO NOT APPLY
VOLTAGE TO YELLOW WIRES. DOING SO WILL VOID WARRANTY.
CURRENT
SENSING
RELAY
SINGLE OR
MULTI-SPEED FAN
C
HI
LO
CAP OFF -
DO NOT CONNECT
TOGETHER
HUMIDISTAT
WARRANTY
FACILITY:
Braeburn Systems LLC
Attn: Warranty Department
2215 Cornell Avenue
Montgomery, IL 60538
PRECAUTIONS
The installer should be a qualified Technician. Disconnect electrical power before beginning installation. Use contacts C and NO
for humidifier operation. Use contacts C and NC for a dehumidifier. Conduct a thorough checkout before leaving the installation.
WIRING DIAGRAMS FOR BRAEBURN
®
220500 and 220600 HUMIDIFIERS
WIRING DIAGRAMS FOR BRAEBURN
®
220700 HUMIDIFIER
On furnaces with output terminals ACC, or EAC check output voltage to determine
that terminals are 115V. Connect on-off switch in series with the hot wire.
On furnaces where it is desirable to use a current sensing relay, the
humidifier may be wired from a continuous 115 volt power source. Install the
on/off switch in series with the hot or black wire. Install the Braeburn
®
229050
Current Sensing Relay in series with the humidistat circuit. The Current
Sensing Relay will detect furnace operation and supply power to the
humidifier accordingly.
C
NO
NC
C
NO
NC
C
NO
NC
C
NO
NC
C
NO
NC
C
NO
NC
USE BOTH WITH
WALL MOUNTING
USE WITH DUCT
MOUNTING ONLY
USE OUTSIDE
PORTION ONLY
WITH DUCT
MOUNTING
GASKET PLACEMENT
FIG. 3*
DUCT MOUNT
VERSION
FIG. 2
DUCT MOUNT BASE
DUCT MOUNT BASE
GASKET
SCREWDRIVER PRY SLOT
WALL MOUNT BASE (229110)
(can mount on duct with
gaskets shown)
*Requires wall mount kit (Model 229110)