background image

TouchTime

®

 

Installation

2

 

3/1/2013

 Bradley 

• 215-1378 Rev. G; ECN 13-10-005

To help prevent electrical damage to the unit, Bradley recommends the use of surge protection. The type of 

surge protection required and its usage is the responsibility of the installer/electrician.

Supplies Required

•  110 VAC power source for 24 VAC Class II transformer 

•  110/24 VAC Class II transformer (available from Bradley as an option)

•  (3) wire nuts to connect power cord leads to transformer wires

Install the 24 VAC Class II transformer in a remote location a safe distance from the area where the 

security fixture is to be used.

(See chart on page 3 for 

part number identification)

Mounting Bracket*

Nut

(161-080)

TouchTime   Sensor

®

Escutcheon

(150-099)

Spring

(135-058)

Standard 

Push Button 

w/Magnet

(S08-311, COLD

S08-312, HOT

S08-313, FLUSH)

Ligature Resistant 

Push Button 

(S08-396)

Security Fixture

B

Insert the push button and spring 

into the escutcheon, then insert 

the escutcheon into through the 

hole in the front of the fixture. 

C

Thread the sensor through the mounting bracket and 

the fixture onto the escutcheon, and secure the valve 

to the fixture by turning nut 1/4 turn past finger-tight). 

NOTE: Use bracket part no. 140-958 for 1-5/8" 

diameter hole (e.g., COMBI 5500). Use bracket 

part no. 140-627 for all square-hole applications.

D

Connect the black and brown power cord leads to the 

wire on the transformer with wire nuts (supplied by 

installer). Turn on the water supply and check for leaking. 

Turn on the 24 VAC power and press the TouchTime

®

 

push button several times to purge air from lines.

1

Installation    

A

Apply 100% silicone caulk to escutcheon 

backside prior to installation to ensure a 

water tight seal. Wipe excess caulk from 

front side of escutcheon and panel.

Содержание TouchTime S45-1941

Страница 1: ...he installation file this manual with the owner or maintenance department Compliance and conformity to local codes and ordinances is the responsibility of the installer Separate parts from packaging and make sure all parts are accounted for before discarding packaging material If any parts are missing do not begin installation until you obtain the missing parts Make sure that all water supply line...

Страница 2: ...t S08 311 COLD S08 312 HOT S08 313 FLUSH Ligature Resistant Push Button S08 396 Security Fixture B Insert the push button and spring into the escutcheon then insert the escutcheon into through the hole in the front of the fixture C Thread the sensor through the mounting bracket and the fixture onto the escutcheon and secure the valve to the fixture by turning nut 1 4 turn past finger tight NOTE Us...

Страница 3: ...hart below for wire color descriptions TOUCHTIME SWITCH BLACK RED RED YELLOW TAPE WIRE NUT supplied by installer To Customer 120v supply SOLENOID VALVE BLACK WIRE BROWN WIRE OUTPUT WIRES see chart below for wire color descriptions TOUCHTIME SWITCH TRANSFORMER BLACK RED RED YELLOW TAPE WIRE NUT supplied by installer To Customer 120v supply TRANSFORMER 2 FEMALE CONNECTORS Transformer may be hard wir...

Страница 4: ...e reading should indicate 24 VAC 10 If you are unable to obtain a proper voltage reading the transformer is not working properly and needs to be replaced Contact your Bradley representative to order the replacement transformer appropriate for your application If the transformer is working properly turn the water supply back on and test the solenoid following the steps outlined in procedure 4 below...

Отзывы: