Bradley Terreon Quadra-Fount TouchTime MF2944 Скачать руководство пользователя страница 5

Installation 

MF2944 - TouchTime

®

 Activation

Bradley • 

215-1539 Rev. K; ECO 19-00-022 7/10/2019 5 

MOUNTING 

PANEL

LOWER

BRACKET

CENTERLINE

PEDESTAL

ASSEMBLY

FLOOR ANCHOR

LOCATION

WALL ANCHOR

LOCATION

A

Measure and mark the centerline of the washfountain 
on the wall and floor .

B

Before mounting the pedestal to the floor, make 
sure the floor is level . If it is not level, be prepared to 
install shims when positioning the pedestal in Step C .

C

With someone to assist you, move the pedestal 
assembly to the wall using appropriate lifting 
procedures, and align the locating notches on the 
mounting panel with the centerline marked on the 
wall . If the floor is not level, install shims under the 
left and/or right pedestal .

D

Drill holes in the wall through the four 1/2" diameter 
holes in the mounting panel and install four anchors 
(supplied by installer) for 

3

/8" bolts .

E

Secure the pedestal assembly to the wall anchors 
using four 

3

/8" bolts and washers (supplied by 

installer) .

F

Drill holes in the floor through the two 1/2" diameter 
holes in the lower bracket and install two anchors 
(supplied by installer) for 

3

/8" bolts .

G

After floor anchors are installed, secure the pedestal 
assembly to the floor anchors using two 

3

/8" bolts 

and washers (supplied by installer) .

Install Pedestal

3

Remove molding strips or tiles which could 
prevent a flush mounting to the wall.

Содержание Terreon Quadra-Fount TouchTime MF2944

Страница 1: ...the installation file this manual with the owner or maintenance department Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material If any part...

Страница 2: ...can be adjusted in the field Solenoid Valve An electronically controlled solenoid valve serves as the metering mechanism Few moving parts provide reliable metering performance and the solenoid is unaf...

Страница 3: ...hown S83 368 Piezo Switch Similar S83 369 Nut Included Hose Stop Prepack TMA S45 2730 Stop Hose TouchTime Module with Mouting Bracket S83 402 Individual TouchTime Module S83 360 Stop Hose 4 Way Splitt...

Страница 4: ...onics and could result in personal injury Compliance and conformity to local codes and ordinances is the responsibility of the installer 11 279 11 279 7 178 17 1 2 445 STD 16 1 2 419 OBC 13 1 2 343 JU...

Страница 5: ...the mounting panel with the centerline marked on the wall If the floor is not level install shims under the left and or right pedestal D Drill holes in the wall through the four 1 2 diameter holes in...

Страница 6: ...ect the other end of each supply hose to the Navigator TMV valve assembly one on the hot side one of the cold side E Mount the valve bracket and module assembly to the left side of the pedestal F For...

Страница 7: ...mber s putty I From beneath bowl thread the spud washer and spud locknut onto the drain spud and tighten the locknut against the bowl J Install strainer in the bowl drain using the two 10 24 x 1 2 fla...

Страница 8: ...er connector to TouchTime module 4x B Connect button connector to TouchTime module 4x C Splitter Connect plug in adapter to splitter D Connect valve connector to TouchTime module 4x D Adjusting the To...

Страница 9: ...stops as this may damage unit Push cover down and tighten screw A Carefully place the top cover with threaded rods on top of washfountain sprayhead B Inside the pedestal assembly of the washfountain u...

Страница 10: ...and work your way toward the more complicated Routine cleaning Daily or as often as needed use a solution of warm water and soap detergent or ammonia Apply the cleaning solution per the manufacturer s...

Страница 11: ...ivate the pushbutton piezo switch on the problem station and the adjacent station should turn on If the adjacent station turns on and cycles normally replace the cartridge on the problem valve If the...

Страница 12: ...eaking stop valves Check the hot water heater output to make sure that it is at least 10 F above the set temperature Be sure to close the appropriate shut off valves prior to disassembly of the valve...

Отзывы: