Installation
SN2003/IR, SN2023/IR
Bradley Corporation
• 215-1073 Rev. H ; EN 10-00-015
7-12-2010
3
Supplies required for installation:
• 3/8" diameter bolts and floor/wall anchors to anchor washfountain pedestal to floor and wall
• 1/2" hot and cold water supply lines and fittings
• 1/2" nom. copper tubing supply lines for types with supplies from above
• Standard P-trap (trap included with “B” or “H” drain type and some optional equipment)
• 1-1/2" drain lines and fittings
• Pipe sealant
Supplies recommended for installation:
• 1-1/2" vent or tie pipe on types vented through washfountain column
• Caulk (may be applied between backsplash and bowl to avoid debris accumulation)
• Electrical cut-off switch to the unit. This feature prevents accidental water delivery during regular maintenance and service.
Dimensions - Sentry
™
Semi-Circular Washfountain
(mm)
Rough-In Locations for Wall Anchor Bracing
Dimensions are to determine reinforcement locations. Use fi xture as a template for precise location of 3/8" anchors.
Floor-Mounted
Units Only
Floor Unit
Wall Mounted
8"
(203)
9"
(229)
8-3/4"
(222)
25-3/4"
(654)
8-3/4"
(222)
25"
(635)
25-3/4"
(654)
8"
(203)
29" (737)
25" (635)
40-1/4" (1022)
36-1/4" (920)
40-1/4" (1022)
36-1/4" (920)
33-1/4" (845)
29-1/4" (743)
33-1/4" (845)
29-1/4" (743)
42-3/4" (1086)
38-3/4" (984)
42-3/4" (1086)
38-3/4" (984)
Juvenile Height dimensions, where
different, are shown in Italics.
13-3/8"
(340)
10"
(254)
9"
(229)
4-3/4"
(121)
8" (203)
8-3/8" (222)
14-3/4" (203)
10-3/4" (101)
24-3/4" (629)
20-3/4" (509)
32-3/4" (832)
28-3/4" (730)
C
L