Installation
S59-2005T1
Bradley
• 215-1501 Rev. F; EN 12-03-009
10/10/2012
3
•
Rough-in 1/2" NPT hot and cold water supply
(supplied by installer).
•
For finished wall, make a 4-1/2" hole in the wall
where the shower handle is desired.
•
For unfinished wall, use the rough-in shield as
a guide. Keep rough-in shield over valve when
finishing wall. The face of the rough-in shield
should fit flush with the finished wall. The rough-in
shield can either be secured to the valve using
the escutcheon screws or press-fit into place.
7"
(178)
24"
(610)
72"
(1829)
48"
(1219)
1/2" (13)
NPT
1-1/2"
(38)
3-1/4" (83) Max.
2-1/2" (64) Min.
3-7/8" (98) Max. Depth
3-1/8" (79) Min. Depth
1/2" NPT Plug
(not supplied)
Shower Only Installation
5"
(127)
6-1/2" (165)
w/ Stops
2-1/2" (64)
w/o Stops
Hot
Cold
Front View
See Step 2 for
required valve
adjustment and
"Back-to-Back"
installation.
"Back-to-Back" Installation
Hot
Cold
Standard
Install
Supplies
Reversed
(mm)
Dimensional Information
Installation Instructions
7"
(178)
72"
(1829)
40"
(1016)
1-1/2"
(38)
1/2" (13)
NPT
3-1/4" (83) Max.
2-1/2" (64) Min.
3-7/8" (98) Max. Depth
3-1/8" (79) Min. Depth
Tub/Shower Installation
12"
(305)
Rough-in
1
32"