background image

2

S19-889EXP2A, S19-889EXP2B

 Installation

6/7/2017 

Bradley • 

215-1862 Rev. B; ECN 17-05-004A

WARNING

Flush the water supply lines before beginning installation and after installation is complete. Test 

the unit for leaks and adequate water flow.

Main water supply to the unit should be "ON" at all times unless system is being serviced. 

Provisions shall be made to prevent unauthorized shutoff.

Power supplied to the unit should be 120VAC or 208-240VAC, 50-60 Hz, 15 amp branch circuit with 

a dedicated circuit breaker or fuse and should not supply power to any other device. Compliance 

and conformity to local codes and ordinances is the responsibility of the installer.

Do not use this safety equipment in a location that does not match its hazardous location rating. 

Verify the appropriate ratings prior to installation.

When making electrical connections be sure to follow all lockout-tagout safety procedures.

CAUTION

Emergency equipment must be supplied with tepid water (60-100°F/15.6-37.8°C). Any prolonged 

exposure to near freezing water affects the body's ability to maintain body temperature, increasing 

the risk of hypothermia.

The unit must be supplied with clean, potable water.

NOTICE

Before installing this product ensure that there are adequate clearances around the product and 

activation of the product does not interfere with other products or obstructions.

It is recommended that all water supply and electrical connections be made at temperatures above 

freezing. Failure to do so may result in major product and/or property damage.

Constant power supply to the safety equipment is necessary for it to function.

Avoid cleaners containing organic solvents, alcohols and hydrocarbons. Rinse with potable water 

after cleaning.