Installation
LC840
Bradley Corporation
• 215-1599 Rev. B; EN 07-1004C
10/24/08
5
5a
Flush Valve Assembly for Flexible Bedpan Washer Option
5b
Flush Valve Assembly for Rigid Bedpan Washer Option
Connect the flush valve
to the vacuum breaker.
C
Connect the compression-fit
elbow to the threaded nipple
on the water closet.
A
Connect the flush valve vacuum
breaker to the compression-fit
elbow.
B
Slip a compression-fit
elbow onto the section
of the inlet pipe coming
from to the bedpan
washer (inlet pipe
may be trimmed, if
necessary).
A
Connect the inlet pipe
to the compression-fit
elbow.
B
Secure the inlet pipe to the
bracket with the U-bolts, nuts
and washers provided.
C
Slip a compression-
fit elbow onto the
section of the outlet
pipe coming from the
bedpan washer.
E
Connect the flush valve to
the end of the inlet pipe with
a compression-fit elbow.
D
Connect the outlet pipe
to the compression-fit
elbow.
F
Connect the outlet pipe
to the threaded nipple
on the water closet.
G
Secure the outlet pipe
to the bracket with
the U-bolts, nuts and
washers provided.
H