background image

LC840 

Installation

4

 

10/24/08

 Bradley 

Corporation

 • 215-1599 Rev. B; EN  07-1004C

3

LC840 Cabinet

With assistance, lift the cabinet 
over the water closet. Position 
the cabinet at the wall and floor 
mounting locations.

B

For cabinets with laminate 
countertop option, remove 
the top prior to installation.

Secure the cabinet to the 
back of the wall at nine 
places with 1/4" fasteners 
(supplied by installer) 
appropriate for the wall 
construction.

D

4

Backfl ow Preventer

Connect the backflow preventer 
outlet pipe to the 1/2" NPT 
bedpan washer hose.

C

Shim and level cabinet 
as necessary.

C

Remove the floor 
template from the 
unit.

A

Not applicable to rigid bedpan washer 
option (ref. Step 5B.) For more details, 
please reference the rough-in submittal 
for the backfl ow preventer.

Connect the 1/2" NPT volume 
control valve outlet (or the optional 
foot valve outlet) to the backflow 
preventer inlet pipe.

IMPORTANT: The backfl ow 
preventer will pipe directly into the 
hand control inlet. The hand control 
does not have an outlet.

B

For Optional Foot Control Valve Assembly:

Remove the screws from the 
foot valve pedal location on 
the unit. Install pre-mounted 
valve with screws.

Connect the piping to the 
backflow preventer inlet 
and outlet per local code.

A

Содержание LC840

Страница 1: ...et U S Patent Nos 6 643 865 and 7 007 318 Table of Contents Pre Installation Information 2 Supplies Required 2 Step 1 Rough Ins 3 Step 2a Wall Mount Water Closet 3 Step 2b Floor Mount Water Closet 3 S...

Страница 2: ...llation manual to ensure proper installation When finished with the installation file this manual with the owner or maintenance department Compliance and conformity to local codes and ordinances is th...

Страница 3: ...ovided D If the floor concrete is lightweight or less than 4 thick Bradley recommends through bolting to steel angles under the floor hardware by installer Using a 5 8 concrete drill bit and the water...

Страница 4: ...PT bedpan washer hose C Shim and level cabinet as necessary C Remove the floor template from the unit A Not applicable to rigid bedpan washer option ref Step 5B For more details please reference the r...

Страница 5: ...section of the inlet pipe coming from to the bedpan washer inlet pipe may be trimmed if necessary A Connect the inlet pipe to the compression fit elbow B Secure the inlet pipe to the bracket with the...

Страница 6: ...f the hose to the foot valve outlet connection A Connect the hot and cold water supply piping to the 1 2 NPT inlet connections on the foot valve B Connect the P trap to the sink s 1 1 4 or 1 1 2 O D d...

Страница 7: ...ticularly under corrosive conditions is essential Always start with the simplest solution and work your way toward the more complicated Routine Cleaning Daily or as often as needed use a solution of w...

Отзывы: