Vernatherm™ Thermostatic Mixing Valve S59-4004XS

S53-302

Installation - For Service Only

8

7/23/07

Bradley Corporation • 215-1525 Rev. G; EN 07-209

9

6

5

4

3

2

1

10

7

8

Strainer
173-028

Valve Body

Spring

Thermostat

Piston

Stem

O-Ring

O-Ring

Cap

Nut 3/8-24 Hex Jam

4

1

Thermostat

6

1

O-Ring

7

1

O-Ring

Item

Qty

Description

Repair Kit S65-259

S45-2082 Checkstop and
Supply Hose Kit

SUPPLY
HOSES 

CHECK STOPS

Содержание Aerada 1100 Series S53-302

Страница 1: ...ted by the user Use extreme caution when installing the device to prevent damage to the exposed significant surface Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material If any parts are missing do not begin installation until you obtain the missing parts Flush water supply lines before making connections DO NOT use pipe dope on any faucet...

Страница 2: ...ing the Filter 7 Frequently Asked Questions 8 Vernatherm Mixing Valve 7 8 ADAPTER OPTIONAL 153 436 IN OUT ON OFF OPERATION BOX FILTER 153 437 TRIMPLATE ASSEMBLY INCL GASKET STUDS HEX NUTS ANTI ROTATIONAL SCREWS 159 422 OPERATION BOX ASSEMBLY S08 366 SENSOR CABLE 269 1753 HOSE BRAIDED 269 1752 FAUCET SENSOR ASSEMBLY INCL HEX NUTS RUBBER WASHER BRASS MTG WASHER S39 601 AERATOR ASSY S05 173 www bradl...

Страница 3: ...nsert the trimplate studs into the deck holes and position the plate onto the deck Secure the plate to the deck with the two 3 8 hex nuts and U brackets provided Thread the two small anti rotational mounting screws into the two holes in the underside of the trimplate and into the two holes in the bottom of the faucet body Make sure screws are aligned with all holes 4 Gently insert the faucet stud ...

Страница 4: ...f Bradley s braided hose to the operation box s 1 2 NPS inlet fitting 3 Connect one end of the braided hose supplied by the installer to the operation box s inlet fitting 4a Connect the other end of the installer s braided hose to the tempered or cold water inlet 4b FOR OPTIONAL VERNATHERM VALVE Connect the other end of the installer s braided hose to the Vernatherm mixing valve IN OUT ON OFF www ...

Страница 5: ... light will turn on 4 Release the button The LED light will turn off The faucet is now in setup mode 5 Place one hand in front of the sensor 2 3 from the sensor window The LED light should flash Hold your hand steady for 5 10 seconds so that the sensor can detect your location 6 Continue to hold one hand 2 3 from the sensor window and then press and release the ON OFF button This will lock the sen...

Страница 6: ... What do I do if the unit activates water runs and does not stop when the water is first turned on A Turn the water off Press and hold the ON OFF button on the operation box for 3 seconds to reset the unit Turn the unit off then turn the water on Place a hand in front of the sensor to test activation of the unit Q What do I do if the unit does not activate when a hand is placed in front of the sen...

Страница 7: ...aning the piston and valve body Remove the thermostat Lift the piston out with a needle nose pliers and remove the spring Any cleaner suitable for brass and stainless steel may be used if cleaning with suitable cleaner is not sufficient to remove debris a 400 grit sandpaper may be used to polish and hone the piston and valve body Snap spring into piston will detent and reassemble into the valve bo...

Страница 8: ...adley Corporation 215 1525 Rev G EN 07 209 9 6 5 4 3 2 1 10 7 8 Strainer 173 028 Valve Body Spring Thermostat Piston Stem O Ring O Ring Cap Nut 3 8 24 Hex Jam 4 1 Thermostat 6 1 O Ring 7 1 O Ring Item Qty Description Repair Kit S65 259 S45 2082 Checkstop and Supply Hose Kit SUPPLY HOSES CHECK STOPS ...