![Bradley Aerada 1100 Series S53-302 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/bradley/aerada-1100-series-s53-302/aerada-1100-series-s53-302_installation-manual_2800144005.webp)
5
Installation - For Service Only
S53-302
Bradley Corporation • 215-1525 Rev. G; EN 07-209
7/23/07
Installation
Step 3: Sensor Range Setup
NOTE: Refer to Figure 3 for sensor
range setup.
NOTE: When connecting the cables,
take care not to bend any of the small
pins on the sensor cable.
1. Apply a small amount of the
silicone lubricant provided to the
operation box cable. Push the
lubricant into the small holes in
the end of the connector.
2. Connect the operation box cable
to the sensor cable as shown. The
arrows on each cable’s end will
point toward each other.
3. Press and hold the “ON/OFF”
button on the operation box for
5–7 seconds. The water will stop
flowing and the LED light will
turn on.
4. Release the button. The LED light
will turn off. The faucet is now in
“setup” mode.
5. Place one hand in front of the
sensor 2"–3" from the sensor
window. The LED light should
flash. Hold your hand steady for
5–10 seconds so that the sensor
can detect your location.
6. Continue to hold one hand 2"–3"
from the sensor window and then
press and release the “ON/OFF”
button. This will lock the sensor
range into memory.
NOTE: The default sensor range is
1"–6" from the sensor window. The range is adjustable from 1"–7".
7. FOR OPTIONAL PLUG-IN AC ADAPTER: Plug one end of the adapter into the adapter inlet
located on the underside of the operation box and the other end into an electrical outlet.
IN
OUT
ON
OFF
www.bradleycorp.com
Figure 3
SENSOR
CABLE
OPERATION BOX
CABLE (push
silicone lubricant
into holes)
OPERATION
BOX
ON/OFF
BUTTON
ADAPTER INLET
(ON UNDERSIDE
OF BOX)