background image

3

Installation 

1WCA Surface Mount Ablution System

Bradley • 

215-1813 Rev. C; ECN 16-03-002 

1/11/2016

Rough-in (as viewed from front)

1

A

Rough-in the wall opening and 
supply piping as required for 
your installation .

Flush supply lines before making connections.

Type

Height

Ablution with seat

29" (740mm)

Ablution without seat

37" (940mm)

Ablution with Lavatory

59" (1499mm)

Recommended Ablution System Height 
(Finished floor to spout/head)

Supply inlets are 3/8" O.D. Comp (without 
supply stop) or 5/8" O.D. comp (with optional 
supply stop) flexible hose and are accessible by 
removing the ablution panel from the wall.

Refer to the product dimensions and images for 
suggested tempered supply line rough-in location.

8" X 8" (203 X 203mm) opening required 

6-1/4"

(159mm)

6-1/4"

(159mm)

5"

(127mm)

5"

(127mm)

5-1/2"

(137mm)

10-3/4"

(273mm)

10-3/4"

(273mm)

5-3/8"

(137mm)

2-1/4"

(55mm)

Spout/Head 

(SPSS type water exit)

Spout/Head 

(SPSS type water exit)

Spout/Head 

(SX type water exit)

Spout/Head 

(SX type water exit)

Supply 

(recommended location)

2" (51mm)

6-1/2"

(166mm)

6-1/2"

(166mm)

2-1/2"

(64mm)

3-5/8"

(92mm)

1-7/8"

(48mm)

7-1/4"

(184mm)

7-1/4"

(184mm)

TT & AST Valves

SV & SVL Valves

2"

(48mm)

6-1/4"

(157mm)

6-1/4"

(157mm)

3-1/2"

(89mm)

Supply 

(recommended location

Отзывы: