Burner Operation Inspection, Cleaning and
R
eplacement
P
a
g
e
17
U
PD
X
Se
r
ie
s
Step 10
.
Reassemble burner and reinstall into water heater
.
Restore gas supply and chec
k
for gas lea
k
s
.
Step 11
.
To resume operation follow the instruction located on the lighting instruction label or the lighting
instruction located in the installation and operating manual
.
Step 4
.
Disconnect (unscrew) feedline from the main burner door
.
Step 5
.
Remove main burner orifice from feed line (3
/
8
"
wrench)
.
Inspect and
clean if necessary
Step 6
.
Remove pilot assembly, refer to UPDX S
E
RVIC
E
PROC
E
DUR
E
II
for cleaning and inspection
.
Step 7
.
Reassemble burner
.
Step 8
.
Reinstall burner and inner door per UPDX S
E
RVIC
E
PROC
E
DUR
E
XV,
steps 10 through 22
.
Step 9
.
To resume operation, follow the instructions located on the lighting instruction label or the lighting
instructions located in the installation and operation manual
.
Feedline
Main
Burner
Orifice
Main
Burner
Door
Burner Cleaning
(
Continued
)
17
Содержание UPDX series
Страница 44: ......