UPV75 Series
Specifications
Power Supply
Dedicated 115 VAC, 60 Hz, 15A.
Gas Supply Pipe
Minimum 1/2” NPT (schedule 40 black iron pipe recommended).
Approved Gas Type
Natural Gas, unit must match gas type supplied.
Gas Pressure
6.0” W.C. min. for Natural Gas, 14.0” W.C. maximum.
Venting System
Power vent through the wall or vertical through the roof.
Approved Vent
Materials
PVC, CPVC or ABS.
Minimum Clearance for
Servicing
18” from top, 24” from front, 4” sides and rear.
Water Supply Pressure 150 PSI maximum allowable working pressure. Check local codes for
supply pressure.
Gas Control ECO Limit Residential 188°F (87°C), Commercial 199°F (93°C).
Residential
Temperature Set Point
Range
60°F (16°C) to 160°F (71°C) (approximate temperatures).
Commercial
Temperature Set Point
Range
80°F (27°C) to 180°F (82°C) (approximate temperatures).
Blower Temperature
Switch
Normally closed, opens @ 155°F (68°C), auto reset @ approximately
135°F (57°C).
Pressure Switch
U(L,R)G2PV75H Models:
Normally open, closes on vacuum increase
@ -0.96" W.C.; Opens on vacuum decrease @ -.91" W.C.
Blower
115 VAC, 60 Hz, 3.3 amps, 3300 RPM.
HIGH ALTITUDE INSTALLATIONS
This appliance has been certified for installations up to 10,100 ft above sea level without modification. Installations greater
than 10,100 ft above sea level are not intended. Unauthorized modifications may result in unsafe operation.
WARNING:
In order to assure the safe and efficient performance of the water heater, it is necessary to follow the vent
connector length rules shown below. Failure to adhere to these rules can result in the unsafe operation of the appliance.
6