DANGER

 

DO NOT store or use gasoline or other flammable, combustible, or corrosive vapors and/or liquids in the vicinity of this or 
any other appliance. 
This  water heater is equipped with an adjustable thermostat to control water temperature.  Hot water temperatures 
required for automatic dishwasher and laundry use can cause scald burns resulting in serious personal injury and/or 
death.  The temperature at which injury occurs varies with the person’s age and the time of exposure.  The slower 
response time of disabled persons increases the hazards to them. 

NEVER

 allow small children to use a hot water tap, or 

to draw their own bath water. 

NEVER

 leave a child or disabled person unattended in a bathtub or shower.  

Toxic chemical, such as those used for boiler treatment, must not be introduced into potable water used for space 
heating. 
This water heater must not be connected to an existing heating system or component(s) previously used with a non-
potable water heating appliance. 
All piping components connected to this water heater for space heating applications must be suitable for use with potable 
water. 

 
 
 
 

 
 

 

WARNING

 

Improper installation, adjustments, alteration, service or maintenance can cause property damage, personal injury or loss 
of life. Failure to follow all instructions in the proper order can cause personal injury or death. Read and understand all 
instructions, including all those provided with the appliance before installing, starting-up, operating, maintaining or 
servicing this appliance. Keep this manual and literature in legible condition with this water heater for reference by owner 
and service technician. 
This water heater requires regular maintenance and service to operate safely. Follow the instructions contained in this 
manual. 
Installation, maintenance, and service must be performed only by a qualified, skilled and knowledgeable installer or 
service provider. 
Installation is not complete unless a temperature and pressure relief valve is installed into the proper location at the top of 
this water heater. 
It is the responsibility of the installing contractor to see that all controls are correctly installed and are properly operating 
when the installation is complete. 
This water heater is suitable for installation on combustible flooring. Do not install water heater directly on carpeting. 
DO NOT operate this water heater without first being certain it is filled with water. 
DO NOT tamper with or alter the water heater and/or controls.  
DO NOT operate water heater with jumpered or absent controls or safety devices.  
DO NOT operate water heater if any external part has been under water. Immediately call a qualified service technician to 
inspect the appliance and to replace any part of the control system including gas controls, which has been under water.  
DO NOT attempt to use this water heater with any gas other than the type listed on the rating plate. Do not attempt to 
convert this water heater for use with a gas other than the type for which it is equipped. Failure to use the proper gas can 
create an unsafe condition resulting in property damage, bodily injury, or death. Consult your local gas supplier or gas 
company if there are any questions. 
Incorrect operation of this appliance may create a hazard to life and property and will nullify the warranty. 
DO NOT operate this water heater if the input rate exceeds the rate shown on the water heater rating plate.  
This water heater contains very hot water under high pressure. Do not unscrew any pipe fittings nor attempt to disconnect 
any components of this water heater without positively assuring the water is cool and is not under pressure. Always wear 
protective clothing and equipment when installing, starting up or servicing this water heater to prevent scald injuries. Do 
not rely on the temperature gauges to determine the temperature. Do not touch any components unless they are cool. 
This water heater must be properly vented and connected to an approved vent system in good condition. DO NOT 
operate water heater with the absence of an approved vent system. A clean and unobstructed vent system is necessary 
to allow noxious fumes that could cause injury or loss of life to vent safely and will contribute toward maintaining the water 
heater’s efficiency. 

Содержание UCG100H199

Страница 1: ...s or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from...

Страница 2: ...e ANSI Z223 1 Latest Edition or in Canada CAN CGA B149 1 Natural Gas Installation Code Latest Edition or CAN CGA B149 2 Propane Installation Code Latest Edition The following terms are used throughout...

Страница 3: ...ter It is the responsibility of the installing contractor to see that all controls are correctly installed and are properly operating when the installation is complete This water heater is suitable fo...

Страница 4: ...e maximum set point can result in scalding hot water delivered to the faucets It is highly recommended that the maximum setpoint be adjusted to the lowest temperature possible for the needs of the ins...

Страница 5: ...80 270 000 64 6 10 44 47 61 55 1 1 UCG80H399 80 399 999 68 8 10 44 47 61 55 1 1 Model Description A Floor to Top of Vent mm B Vent Dia mm C Floor to Cold Water Conn mm D Floor to T P mm E Floor to Hot...

Страница 6: ...the back of this Installation and Operating Instruction Manual ADJUSTABLE THERMOSTAT This water heater is equipped with an adjustable thermostat as part of the Integrated Control System to control wa...

Страница 7: ...re and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements of th...

Страница 8: ...heavier than air and will remain at floor level if there is a leak Basements crawl spaces closets and areas below ground level will serve as pockets for accumulation of leaking gas Before lighting sm...

Страница 9: ...extending beyond the full width and depth of the appliance by at least three 3 inches 7 6 cm in any direction or if the appliance is to be installed in an alcove or closet the entire floor must be cov...

Страница 10: ...sides and Rear A Less than or equal to 270 000 BTUH 0 in 0 0 CM 399 999 BTUH 0 in 0 0 CM 2 in Rear ONLY Figure 2a Minimum Clearance To Combustible Material Figure 2b Recommended Minimum Clearances For...

Страница 11: ...serious damage to the water heater and risk of fire or explosion It can also create a risk of asphyxiation Such a condition often will result in a yellow luminous burner flame causing carboning or so...

Страница 12: ...nfined spaces in buildings infiltration may be adequate to provide air for combustion ventilation and dilution of flue gases However in buildings of tight construction for example weather stripping he...

Страница 13: ...he venting installation is complete and the piping completed Failure to complete installation before operation can result in property damage personal injury or death The venting system must be install...

Страница 14: ...rafts during shutdown periods CAUTION The vent shall terminate a minimum of 12 inches above expected snowfall level to prevent blockage of vent termination The horizontal centerline of the exhaust ven...

Страница 15: ...located above the terminal within a horizontal distance of 2 feet 61 cm from the center line of the terminal b b K Clearance to a mechanical air supply inlet 6 feet 1 83 m 3 feet 91 cm above if within...

Страница 16: ...away from the water heater The vent system must be supported every 5 feet of vertical run and every 3 feet of horizontal run of vent pipe length CAUTION Failure to properly support the vent piping wit...

Страница 17: ...and every 3 feet of horizontal run of vent pipe length CAUTION Failure to properly support the vent piping with hangers and clamps may result in damage to the water heater or venting system Figure 5 T...

Страница 18: ...270 20 50 75 UCG80H399 N A 25 50 Determining required vent length 1 Determine the total length of straight vent pipe in feet required for the intake 2 Add 5 feet of venting for every 90 elbow 3 Add 2...

Страница 19: ...TER Table 3 Scald Times APPROXIMATE TIME TEMPERATURE RELATIONSHIPS IN SCALDS 120 F 49 C More than 5 minutes 125 F 52 C 1 to 2 minutes 130 F 54 C About 30 seconds 135 F 57 C About 10 seconds 140 F 60 C...

Страница 20: ...temperature steam BTU discharge capacity not less than the hourly rating of the water heater Install the combination temperature and pressure relief valve into the opening provided and marked for thi...

Страница 21: ...y shut off valve 4 Open the drain valve on the water heater by turning the slot on the valve counter clockwise The drain valve has threads on the end that will allow the connection of a standard hose...

Страница 22: ...he water heater Refer to Figure 7 and Figure 8 for installation examples Maintain a minimum 1 2 clearance from hot water piping to combustible materials Figure 7 Alternate Space Heating Connections Fi...

Страница 23: ...OPEN FLAME FOR TESTING 3 While checking for leaks care must be taken to prevent solution from contacting the electrical connections at the control If electrical connections at the control become wet...

Страница 24: ...rdance with the operating instructions label attached to the water heater Under no circumstances should the input rate exceed the input rate shown on the water heater rating plate Over firing could re...

Страница 25: ...ord provided on the control box Do not plug the line cord into a receptacle that can have the power supply interrupted by a switch that is used to control lights or another appliance If wiring in cond...

Страница 26: ...ve steps have been made by a factory authorized independent service contractor or qualified service professional 1 Flooding to or above the level of the burner or controls 2 External firing 3 Damage 4...

Страница 27: ...E ADJUSTMENT APPROXIMATE TIME TEMPERATURE RELATIONSHIPS IN SCALDS 120 F 49 C More than 5 minutes 125 F 52 C 1 to 2 minutes 130 F 54 C About 30 seconds 135 F 57 C About 10 seconds 140 F 60 C Less than...

Страница 28: ...gas control gas pressure MUST be monitored and properly adjusted no less than every 6 months thereafter This water heater when set at a lower temperature setting is not capable of producing hot water...

Страница 29: ...ion To avoid unnecessary expense and inconvenience make sure the tank is leaking before calling a service person If the water heater display does not show Operational in the Status indicator there may...

Страница 30: ...r pressing Temperature Up button SELECT SET Status Set button Select button Temperature Down Button Temperature Up Button F idle setpoint Operational Sequence of operation Indicator Reads Idle or Heat...

Страница 31: ...s and hold Temperature Down button until desired setpoint temperature appears in the display Step 2 Setpoint indicator begins flashing in the display after pressing Temperature Down button SELECT SET...

Страница 32: ...ture Format in Display from F to C or C to F Step 1 Press SELECT button until F C is displayed Step 2 Press SET button to change temperature format Symbol F C will flash SELECT SET Status idle Operati...

Страница 33: ...button to confirm F or C format F C will stop flashing Setpoint display will appear in the format selected F or C in 10 seconds SELECT SET Status F idle Operational Step 4 Press Set F C Symbol F C St...

Страница 34: ...ally two weeks or more Hydrogen gas is extremely flammable To prevent the possibility of injury under these conditions we recommend the hot water faucet to be open for several minutes at the kitchen s...

Страница 35: ...val of lime scale The unit should be inspected and adjusted to maintain proper combustion Refer to Table 5 Suggested Maintenance Schedule A periodic inspection of the venting system should be made BUR...

Страница 36: ...Open the heater drain valve 7 If the water heater is being drained for an extended shutdown it is suggested the drain valve be left open during this period FILLING WATER HEATER 1 Close the water heat...

Страница 37: ...he anode requiring frequent inspections The replacement anodes rods are available from your plumbing professional To inspect or replace an anode The anodes on this water heater are easily accessible f...

Страница 38: ...ake system every 3 months Points of inspection are as follows 1 Check for obstructions and or deterioration of vent piping and vent terminal Replace immediately where needed 2 Vent pipe and vent termi...

Страница 39: ...water heater display Removing the blockage and resetting the switch will resume normal operation 5 The burner flame is monitored by the flame sense circuit and if the flame should extinguish the gas v...

Страница 40: ...s only shown if there is an operating error in the User Mode NOTICE Approximately 12 minutes after the last button press the display will automatically return to the User Mode Simultaneously pressing...

Страница 41: ...ing 3 Flame Current of Pilot Flame Sensor Displays only in the Heating Cycle SELECT SET Status Heating Operational Flame Current A SELECT SET Status F idle Water Temp Operational SELECT SET Status idl...

Страница 42: ...5 F C Display Change 6 Differential Display only shows the differential of the thermostat SELECT SET Status F idle Differential Operational SELECT SET Status F C idle Operational F SELECT SET Status...

Страница 43: ...ode History Displays if there are present error codes or up to 10 previous error codes Water Heater Display will show if there are no error codes SELECT SET Status idle Operational No current error co...

Страница 44: ...delivered to the faucets It is highly recommended that the maximum setpoint be adjusted to the lowest temperature possible for the needs of the installation See following section to change the maximum...

Страница 45: ...isplay will go back to User Mode It will read Max Setpoint without showing a temperature value if the temperature setpoint is at the maximum setting The Water Heater Display can be set back to the Use...

Страница 46: ...ot flame sense current is available only when the burners are in operation Step 1 Make sure the status displays Heating or draw enough hot water to start the burners Step 2 Enter the Service Mode desc...

Страница 47: ...limited to the Max Setpoint described previously To change the Max Setpoint refer to the procedure To Change the Maximum Setpoint Limit described previously under Accessing the Service Mode on the Wat...

Страница 48: ...to confirm the new setpoint Setpoint stops flashing in the water heater display To Change Temperature Format in Display from F to C or C to F Step 1 While in Service Mode press Select button until F C...

Страница 49: ...ess Temperature Up button to change temperature format to C Step 3b Press Temperature Down button to change temperature format to F SELECT SET Status idle Operational F Changes to F F C F C Flashes SE...

Страница 50: ...ill stop flashing Step 5 Pressing Select button will return display to setpoint in format selected F or C immediately SELECT SET Status F idle Operational Lower Sensor Setpoint shown in F SELECT SET S...

Страница 51: ...ut the water heater into a Hard Lockout condition in which the water heater will not operate and cannot be reset in the User Mode To reset a hard lockout first enter the Service Mode described earlier...

Страница 52: ...lect button after the Software Version item 8 in the previously described sequence of service modes will show an error code history if there have been any previous operating problems with the water he...

Страница 53: ...ext to the water heater display will identify the code number If no number is displayed with only a in the water heater display then there has not been an error code for error code index 10 Step 4 Pre...

Страница 54: ...code index The water heater display will store up to 10 error codes with the oldest code starting in code index 1 with the most recent code in code index 10 Step 7 10 seconds after the last button pre...

Страница 55: ...make sure gas valve has closed No voltage should be present at the gas valve before the ignition cycle Make sure wire positions on the wire harness are correct If gas valve is stuck open replace 26 E...

Страница 56: ...lower harness and then at blower pin connections Replace control wire harness or blower if defective Check to make sure vent terminals are clear of debris or snow and ice Make sure the condensate drai...

Страница 57: ...7869 7685 7507 90 7333 7165 7000 6839 6683 6531 6383 6238 6098 5961 100 5827 5697 5570 5446 5326 5208 5094 4982 4873 4767 110 4663 4562 4464 4368 4274 4183 4094 4006 3922 3839 120 3758 3679 3602 3527...

Страница 58: ...ntrol Display 9 Front Cold Water Inlet 10 Plastic Hole Closure 11 No Handle Brass Drain Valve 12 Cleanout Access Cover 13 Screw 5 16 18 x 3 4 HH Grade 5 14 Cleanout Cover 15 T P Specify Model 16 Hot W...

Страница 59: ...model 16 Gasket Burner Specify Model 5 Gasket Screw 17 Burner Specify Model 6 Transition Tube 18 Burner Mount Assembly 7 Gasket Blower Transition 19 Sight Glass Assembly 8 Gasket Transition Tube 20 Ga...

Страница 60: ...8 146 772 Other U S and Foreign patent applications pending Current Canadian Patents 2 092 105 2 107 012 2 108 186 2 112 515 2 143 031 2 239 007 2 262 174 2 314 845 2 409 271 2 476 685 2 504 824 2 54...

Отзывы: