Installation (Locating The Water Heater) continued- 

 

 

Water heater corrosion and component failure can be caused by the heating 
and breakdown of airborne chemical vapors. Examples of some typical 
compounds that are potentially corrosive are: spray can propellants, cleaning 
solvents, refrigerator and air conditioning refrigerants, swimming pool 
chemicals, calcium and sodium chloride, waxes and process chemicals. These 
materials are corrosive at very low concentration levels with little or no odor to 
reveal their presence. 

NOTE: DAMAGE TO THE WATER HEATER CAUSED 

BY EXPOSURE TO CORROSIVE VAPORS IS NOT COVERED BY THE 
WARRANTY.  DO NOT OPERATE THE WATER HEATER IF EXPOSURE 
HAS OR WILL OCCUR.  DO NOT STORE ANY POTENTIALLY CORROSIVE 
COMPOUNDS IN THE VICINITY OF THE WATER HEATER. 

 

For exact venting specifications, please consult the Venting section of these 
Installation and Operating Instructions.

  

It is recommended that a minimum 

clearance of 4 inches 

(10.2 cm)

 be provided on the side of the water heater for 

servicing and maintenance of the combination temperature and pressure relief 
valve. 

 

 

WARNING 

Water heaters are heat producing appliances. To avoid damage or 
injury there must be no materials stored against the water heater or 
vent-air intake system and proper care must be taken to avoid 
unnecessary contact (especially by children) with the water heater and 
vent-air intake components. UNDER NO CIRCUMSTANCES MAY 
FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT 
THINNER BE USED OR STORED IN THE VICINITY OF THIS WATER 
HEATER, VENT-AIR INTAKE SYSTEM OR IN ANY LOCATION FROM 
WHICH FUMES COULD REACH THE WATER HEATER OR VENT-
AIR INTAKE SYSTEM. 

 

WARNING 

DO NOT ATTEMPT TO LIGHT ANY GAS APPLIANCE IF YOU ARE 
NOT CERTAIN OF THE FOLLOWING: 
•  Liquefied petroleum gases/propane gas and natural gas have an 
odorant added by the gas supplier that aids in detection of the gas. 
•  Most people recognize this odor as a “sulfur” or “rotten egg” smell. 
•  Other conditions, such as “odorant fade” can cause the odorant to 
diminish in intensity, or “fade”, and not be as readily detectable. 
•  If you have a diminished sense of smell, or are in any way unsure of 
the presence of gas, immediately contact your gas supplier from a 
neighbor’s telephone. 
•  Gas detectors are available.  Contact your gas supplier or plumbing 
professional for more information. 

Содержание RG2DVMH30T6X-264

Страница 1: ...nstalled and serviced by a plumbing professional MANUFACTURED HOME MOBILE HOME CLOSED COMBUSTION DIRECT VENTING INSTALLATION AND OPERATING INSTRUCTION MANUAL FOR YOUR SAFETY Do not store or use gasoli...

Страница 2: ...installation of this water heater We require that you carefully read this manual as well as the enclosed warranty and refer to it when questions arise If you have any specific questions concerning you...

Страница 3: ...arances 8 Drain Pan Installation 9 Combustion Air Supply 10 Venting 11 Water Connections 12 Gas Connections 15 Gas Conversion Instructions 16 GENERAL OPERATION 20 Lighting and Shutdown Instructions 21...

Страница 4: ...ntake tube and heater tie down materials These components for field installation may have been shipped with this heater and must be installed according to these instructions see figure 1 No other comp...

Страница 5: ...tionally the water heater should be flushed with appropriate dissolvers to eliminate any bacteria INSTALLATION Locating the Water Heater This water heater MUST NOT be installed in any location where g...

Страница 6: ...ature and pressure relief valve WARNING Water heaters are heat producing appliances To avoid damage or injury there must be no materials stored against the water heater or vent air intake system and p...

Страница 7: ...eater is to be a Sealed to the floor with sealant in a smooth and easily cleanable way or b Installed with an optional leg kit that includes legs and or extensions that provide a minimum clearance of...

Страница 8: ...r wood panel or equivalent extending beyond the full width and depth of the appliance by at least 3 inches 7 6 cm in any direction or if the appliance is to be installed in an alcove or closet the ent...

Страница 9: ...final installation 4 Align drain pan hole with hole cut in floor and underside sheathing for air intake 5 Apply 4 diameter circle of silicone around bottom of air intake plate and screws used to secu...

Страница 10: ...yellow luminous burner flame causing carboning or sooting of the combustion chamber burners and flue tubes with possible damage to the heater AIR INTAKE INSTALLATION 3 7 6cm diameter telescoping air...

Страница 11: ...e fastened to the top of the water heater and to the adjacent walls with the screws provided See Figure 5 Venting Make certain the flue baffle is in place and centered in the flue tube Cut a 7 1 4 inc...

Страница 12: ...let and hot water outlet are dielectric waterway fittings with 3 4 NPT male thread Make the proper plumbing connections between the water heater and the plumbing system to the house Install a shut off...

Страница 13: ...Vacuum Relief Valves The combination temperature and pressure relief valve must be marked with a maximum set pressure not to exceed the maximum working pressure of the water heater The combination te...

Страница 14: ...e tank for a long period of time generally two weeks or more Hydrogen gas is extremely flammable To prevent the possibility of injury under these conditions we recommend the hot water faucet to be ope...

Страница 15: ...dope has become lodged in the inlet screen of the gas valve Extreme care must be taken to ensure no pipe dope enters the gas valve Avoid excessive torque when tightening the gas supply line to the gas...

Страница 16: ...or by removing cap from gas regulator Depress and rotate knob clockwise to NAT setting using a screwdriver Replace cap Figure 6 3 Change the pilot regulator by removing pilot regulator cap Depress and...

Страница 17: ...provided with the water heater 2 Change the main gas regulator to LP as noted in step 2 of the instructions 3 Change the pilot regulator to LP as noted in step 3 of the instructions 4 Replace equipped...

Страница 18: ...igure 7 only 1 Follow the instructions above except remove cap from gas regulator and depress and rotate plunger counterclockwise 2 Remove main burner orifice and pilot assembly and replace with RED c...

Страница 19: ...cedure 9 To light pilot follow the lighting instructions provided on the water heater and in this installation and operation instruction manual 10 Remove equipped for card from cloth bag and attach to...

Страница 20: ...e gas control knob clockwise to the OFF position OR for the Robertshaw control rotate the gas control knob clockwise to the OFF position 3 Shut off the gas supply to the water heater 4 Close the cold...

Страница 21: ...21 Lighting and Shutdown Instructions...

Страница 22: ...al until the minimum acceptable temperature is achieved See Figure 9 above for approximate temperature settings Figure 10 The thermostat dial is set to its lowest temperature setting when shipped from...

Страница 23: ...thermostat dial It is suggested that the starting point setting not be greater than the mark on the thermostat dial approximately 120 F 48 9 C as pictured above Rotate the thermostat dial clockwise to...

Страница 24: ...the water system This valve will reduce point of discharge temperature by mixing cold and hot water in branch water lines A licensed plumbing professional or local plumbing authority should be consult...

Страница 25: ...tion temperature and pressure relief valve to insure that the valve has not become encrusted with lime Lift the lever at the lever at the top of the valve several times until the valve seats properly...

Страница 26: ...E WATER HEATER ARE WARRANTED Manufactured under one or more of the following U S Patents 5 277 171 5 341 770 5 372 185 5 485 879 5 574 822 5 596 952 5 660 165 5 682 666 5 761 379 5 943 984 5 954 492 5...

Страница 27: ...27 TYPICAL INSTALLATION...

Страница 28: ...oor 2 Jacket Top 13 Convertible gas control valve 3 Fiberglass Insulation 14 Pilot Assembly 4 Glass Lined Tank 15 Gas Feed Line Burner 5 Tank Skirt Assembly 16 Main Burner Orifice 6 Jacket Base Assemb...

Отзывы: