GENERAL INFORMATION 

 

This water heater must be installed in accordance with The Federal 
Manufactured Home Construction And Safety Standard (H.U.D. Title 24, Part 
3280.707d2) or CAN/CSA Z240 MH series, mobile home.  In the absence of 
such a standard, the water heater should be installed in accordance with the 
Standard For Mobile Homes (ANSI/NFPA NO. 501-B1977). 

 

The warranty for this water heater is in effect only when the water heater is 
installed, adjusted, and operated in accordance with these Installation and 
Operating Instructions.  The manufacturer will not be liable for any damage 
resulting from alteration and/or failure to comply with these instructions. 

 

This water heater is of the closed combustion type (direct venting) where all the 
combustion air is supplied from the outdoors through the air intake and all 
combusted gas products are vented directly to the outside by means of the roof 
jack.  No draft diverter (vent hood) is required for this water heater. 

 

INTERTEK has tested a representative sample of this water heater design for 
its safety of operation.  The ETL listing of this water heater includes the field 
installation of the following components: roof jack, air intake tube, and heater 
tie down materials. These components for field installation may have been 
shipped with this heater and must be installed according to these instructions 
(see figure 1).  No other components are approved for use with this water 
heater. 

 

This water heater has been designed and certified for the purpose of heating 
potable water.  The installation and use of this water heater for any purpose 
other than the heating of potable water may cause damage to the water heater, 
create a hazardous condition, and nullify the warranty. 

 

 

 
Do not use this appliance if any external part to the tank has been submerged 
in water. You should contact a qualified service technician to inspect the 
appliance and to replace any part of the control system including the 
combination gas control which has been submerged in water. See the Gas 
Connections section of this manual before servicing or replacing a water heater 
that has had any external part to the tank submerged in water. 
 

 

CAUTION 

Incorrect operation of this appliance may create a hazard to life and 
property and will nullify the warranty.

 

WARNING 

Prior to connecting the gas supply line to a gas fired water heater, 
ensure that the gas supply line does not have moisture/water or 
dirt/scale inside the gas line.  Commonly this check is done at the 
lowest point in the gas distribution system prior to gas burning 
appliances.

 

Содержание RG2DVMH30T6X-264

Страница 1: ...nstalled and serviced by a plumbing professional MANUFACTURED HOME MOBILE HOME CLOSED COMBUSTION DIRECT VENTING INSTALLATION AND OPERATING INSTRUCTION MANUAL FOR YOUR SAFETY Do not store or use gasoli...

Страница 2: ...installation of this water heater We require that you carefully read this manual as well as the enclosed warranty and refer to it when questions arise If you have any specific questions concerning you...

Страница 3: ...arances 8 Drain Pan Installation 9 Combustion Air Supply 10 Venting 11 Water Connections 12 Gas Connections 15 Gas Conversion Instructions 16 GENERAL OPERATION 20 Lighting and Shutdown Instructions 21...

Страница 4: ...ntake tube and heater tie down materials These components for field installation may have been shipped with this heater and must be installed according to these instructions see figure 1 No other comp...

Страница 5: ...tionally the water heater should be flushed with appropriate dissolvers to eliminate any bacteria INSTALLATION Locating the Water Heater This water heater MUST NOT be installed in any location where g...

Страница 6: ...ature and pressure relief valve WARNING Water heaters are heat producing appliances To avoid damage or injury there must be no materials stored against the water heater or vent air intake system and p...

Страница 7: ...eater is to be a Sealed to the floor with sealant in a smooth and easily cleanable way or b Installed with an optional leg kit that includes legs and or extensions that provide a minimum clearance of...

Страница 8: ...r wood panel or equivalent extending beyond the full width and depth of the appliance by at least 3 inches 7 6 cm in any direction or if the appliance is to be installed in an alcove or closet the ent...

Страница 9: ...final installation 4 Align drain pan hole with hole cut in floor and underside sheathing for air intake 5 Apply 4 diameter circle of silicone around bottom of air intake plate and screws used to secu...

Страница 10: ...yellow luminous burner flame causing carboning or sooting of the combustion chamber burners and flue tubes with possible damage to the heater AIR INTAKE INSTALLATION 3 7 6cm diameter telescoping air...

Страница 11: ...e fastened to the top of the water heater and to the adjacent walls with the screws provided See Figure 5 Venting Make certain the flue baffle is in place and centered in the flue tube Cut a 7 1 4 inc...

Страница 12: ...let and hot water outlet are dielectric waterway fittings with 3 4 NPT male thread Make the proper plumbing connections between the water heater and the plumbing system to the house Install a shut off...

Страница 13: ...Vacuum Relief Valves The combination temperature and pressure relief valve must be marked with a maximum set pressure not to exceed the maximum working pressure of the water heater The combination te...

Страница 14: ...e tank for a long period of time generally two weeks or more Hydrogen gas is extremely flammable To prevent the possibility of injury under these conditions we recommend the hot water faucet to be ope...

Страница 15: ...dope has become lodged in the inlet screen of the gas valve Extreme care must be taken to ensure no pipe dope enters the gas valve Avoid excessive torque when tightening the gas supply line to the gas...

Страница 16: ...or by removing cap from gas regulator Depress and rotate knob clockwise to NAT setting using a screwdriver Replace cap Figure 6 3 Change the pilot regulator by removing pilot regulator cap Depress and...

Страница 17: ...provided with the water heater 2 Change the main gas regulator to LP as noted in step 2 of the instructions 3 Change the pilot regulator to LP as noted in step 3 of the instructions 4 Replace equipped...

Страница 18: ...igure 7 only 1 Follow the instructions above except remove cap from gas regulator and depress and rotate plunger counterclockwise 2 Remove main burner orifice and pilot assembly and replace with RED c...

Страница 19: ...cedure 9 To light pilot follow the lighting instructions provided on the water heater and in this installation and operation instruction manual 10 Remove equipped for card from cloth bag and attach to...

Страница 20: ...e gas control knob clockwise to the OFF position OR for the Robertshaw control rotate the gas control knob clockwise to the OFF position 3 Shut off the gas supply to the water heater 4 Close the cold...

Страница 21: ...21 Lighting and Shutdown Instructions...

Страница 22: ...al until the minimum acceptable temperature is achieved See Figure 9 above for approximate temperature settings Figure 10 The thermostat dial is set to its lowest temperature setting when shipped from...

Страница 23: ...thermostat dial It is suggested that the starting point setting not be greater than the mark on the thermostat dial approximately 120 F 48 9 C as pictured above Rotate the thermostat dial clockwise to...

Страница 24: ...the water system This valve will reduce point of discharge temperature by mixing cold and hot water in branch water lines A licensed plumbing professional or local plumbing authority should be consult...

Страница 25: ...tion temperature and pressure relief valve to insure that the valve has not become encrusted with lime Lift the lever at the lever at the top of the valve several times until the valve seats properly...

Страница 26: ...E WATER HEATER ARE WARRANTED Manufactured under one or more of the following U S Patents 5 277 171 5 341 770 5 372 185 5 485 879 5 574 822 5 596 952 5 660 165 5 682 666 5 761 379 5 943 984 5 954 492 5...

Страница 27: ...27 TYPICAL INSTALLATION...

Страница 28: ...oor 2 Jacket Top 13 Convertible gas control valve 3 Fiberglass Insulation 14 Pilot Assembly 4 Glass Lined Tank 15 Gas Feed Line Burner 5 Tank Skirt Assembly 16 Main Burner Orifice 6 Jacket Base Assemb...

Отзывы: