NATURAL GAS AND LIQUID PROPANE GAS
Extra Recovery Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
79% and 80% Recovery Efficiency
Model
Number
Approx.
Shipping
Weight
lbs.
E
Floor to
Gas
Conn.
in.
A
Floor to
Flue
Conn.
in.
B
Jacket
Dia.
in.
U.S.
Gal.
Capacity
Recovery*
90°F Rise
M-1
-XR403S6FBN
M-2
-XR504T6FBN
M-2
-XR65T6FBN
40
48
65
Imp.
Gal.
33
40
54
Nat.
BTU/Hr.
Input
40,000
65,000
65,000
Nat.
U.S.
GPH
43
69
69
Nat.
Imp.
GPH
36
57
57
LP
U.S.
GPH
40
65
67
LP
Imp.
GPH
33
54
56
126
164
205
20
22
24
C
Vent
Size
in.
3x4
4
4
50
59
1
/
4
63
13
13
12
3
/
16
48
1
/
2
57
60
3
/
4
41
50
53
1
/
2
H
Floor to
Water
Conn.
in.
D
Floor to
T&P
Conn.
in.
Model
Number
Approx.
Shipping
Weight
kg.
E
Floor to
Gas
Conn.
mm.
A
Floor to
Flue
Conn.
mm.
B
Jacket
Dia.
mm.
Liters
Capacity
Recovery*
50°C Rise
M-1
-XR403S6FBN
M-2
-XR504T6FBN
M-2
-XR65T6FBN
151
182
246
Nat.
kW
Input
11.7
19.1
19.1
LP
BTU/Hr.
Input
38,000
61,000
63,000
LP
kW
Input
11.1
19.1
18.5
Nat.
Liters/
Hour
163
261
261
LP
Liters/
Hour
151
246
253
57
74
93
508
559
609
C
Vent
Size
mm.
76 / 102
102
102
1270
1505
1600
330
330
309
F
Floor to
Space
Heating
Return
in.
13
1
/
2
13
1
/
2
13
1
/
2
F
Floor to
Space
Heating
Return
mm.
343
343
342
G
Floor to
Space
Heating
Outlet
in.
41
50
53
1
/
2
G
Floor to
Space
Heating
Outlet
mm.
1041
1270
1359
1232
1448
1543
1041
1270
1359
H
Floor to
Water
Conn.
mm.
24
26
28
K
Depth
in.
609
660
711
K
Depth
mm.
D
Floor to
T&P
Conn.
mm.
Residential Atmospheric Vent Gas Water Heater
Meets NAECA Requirements
General
All gas water heaters are certified at 300 PSI (2068 kPa) test pressure and 150 PSI (1034 kPa) working pressure. All water connections are 3⁄4" (19mm) NPT.
All gas connections are 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and/or peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.
Propane models feature a Titanium Stainless Steel propane burner. For Propane (LP) models change suffix "BN" to "SX".
M-2-XR65 features a Cast Iron burner. For Propane (LP) model change suffix "BN" to"CX".
For 10 year models, change suffix from “6” to “10”.
*Based on manufacturers rated recovery efficiency.
E
C
**
B
A
H
K
D&G
F
E
C
**
B
A
H
K
D&G
F
**M-1-XR403S water connections are on 8" centers, all other models are 11" centers.
Printed in U.S.A.
109-B-0808-A
©2008, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales 800-523-2931
●
Fax 215-641-1670 / Technical Support 800-334-3393
●
Fax 269-795-1089
●
Warranty 800-531-2111
●
Fax 269-795-1089
International:
Telephone 215-641-9400
●
Telefax 215-641-9750 / www.bradfordwhite.com
Sales / Technical Support 866-690-0961 / 905-238-0100
●
Fax 905-238-0105 / www.bradfordwhite.com