background image

NATURAL GAS AND LIQUID PROPANE GAS

Upright Energy Saver Models 

Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed

Recovery efficiency ranging up to 78% (M-I-75S and M-I-100T have an 80% recovery efficiency)

Model

Number

Capacity

F

Floor to

Water
Conn.

in.

Approx.

Shipping

Weight

lbs.

E

Floor to

Gas

Conn.

in.

A

Floor to

Flue

Conn.

in.

D

Floor to

T&P

Conn.

in.

C

Vent

Size

in.

B

Jacket

Dia.

in.

Gal.

U.S.

Recovery 

90

°

F Rise*

30

32,000

16

59

1

8

3x4

104

49

3

4

33

M

-I-

30T6FBN

30

30,000

31,000

26,000

18

3x4

100

38

3

4

57

1

2

46

3

4

13

13

48

3

8

31

M

-I-

30S6FBN

29

40,000

16

58

3x4

109

49

3

4

42

M

-I-

303T6FBN

40

40,000

35,000

36,000

18

3x4

120

50

56

1

2

57

3

4

13

13

59

3

8

42

M

-I-

40T6FBN

40

40,000

20

50

3x4

128

41

42

M

-I-

403S6FBN

40

50,000

38,000

48,000

18

4

127

51

1

2

48

1

2

58

1

2

13

13

60

3

4

53

M

-I-

404T6FBN

50

40,000

20

59

5

8

3x4

145

50 57

42

M

-I-

5036FBN

48

40,000

36,000

38,000

22

3x4

153

40

1

2

58

48

1

4

13

13

49

3

4

42

M

-I-

50L6FBN

50

50,000

20

58

1

2

4

150

50

53

M

-I-

504S6FBN

75

76,000

48,000

76,000

4

264

53

57

61

1

4

13

16

63

3

4

82

M

-I-

75S6BN

100

Gal.

Imp.

GPH

Nat.
U.S.

GPH

LP
U.S.

25

25

24

33

33

33

42

40

42

63

83

85,000

88,000

4

/

/

/

/

/

/

/

420

59

5

16

56

3

8

55

1

4

56

5

8

47

1

4

58

55

3

4

24

1

2

28

1

4

15

5

8

68

11

16

65

11

16

92

28

26

34

34

34

44

34

34

44

69

GPH

Nat.
Imp.

Input

Nat.

BTU/Hr.

Input

LP

BTU/Hr.

77

32

27

37

38

40

50

38

40

50

82

95

GPH

LP
Imp.

27

23

31

32

33

42

32

33

42

69

80

M

-I-

100T6BN

M

-I-

30T6FBN

M

-I-

30S6FBN

M

-I-

303T6FBN

M

-I-

40T6FBN

M

-I-

403S6FBN

M

-I-

404T6FBN

M

-I-

5036FBN

M

-I-

50L6FBN

M

-I-

504S6FBN

M

-I-

75S6BN

M

-I-

100T6BN

Model

Number

Capacity

Liters

F

Floor to

Water
Conn.

mm.

Approx.

Shipping

Weight

kg.

E

Floor to

Gas

Conn.

mm.

A

Floor to

Flue

Conn.

mm.

D

Floor to

T&P

Conn.

mm.

C

Vent

Size

mm.

B

Jacket

Dia.

mm.

Recovery 

50

°

C Rise*

114

9.4

125

114

8.8

9.1

7.7

117

1502

1229

406

457

76x102

76x102

1264

9841

330

330

1461

1187

47

45

110

11.7

159

151

11.7

10.3

10.6

155

1473

1508

406

457

76x102

76x102

1264

1270

330

330

1435

1467

49

54

151

11.7

155

151

14.7

11.1

14.1

201

1270

1543

508

457

76x102

102

1041

1308

330

330

1232

1486

58

58

189

11.7

159

182

11.7

10.6

11.1

159

1514

1264

508

559

76x102

76x102

1270

1029

330

330

1473

1226

66

69

189

14.7

201

284

22.3

14.1

22.3

310

1486

1619

508

622

102

102

1270

1346

330

406

1448

1518

68

120

379

24.9

25.7

348

1745

718

102

/

/

/

/

/

/

/

1507

1432

1403

1438

1200

1473

1445

1416

397

1651

191

121

102

140

140

148

189

144

151

189

310

60

40,000

38,000

3x4

166

58

1

4

50

1

2

13

60

3

4

42

M

-I-

60T6FBN

50

22

34

40

33

M

-I-

60T6FBN

227

11.7

11.1

163

1543

609

76x102

1282

330

1480

75

151

359

Nat.

Liters/

Hour

LP

Liters/

Hour

Nat.

kW

Input

LP

kW

Input

Residential Atmospheric Vent Gas Water Heater

Meets NAECA Requirements
General

All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3⁄4" NPT (19mm)
on 8" (203mm) centers. The 75 gallon model (284 liters) has 1" (25mm) NPT on 11" (279mm) centers and 100 gallon model (379 liters) has 1

1

4

" (32mm)

water connections on 16" (406mm) centers. All gas connections are 1⁄2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), ANSI standard Z-21.10.1 and/or 10.3 and peak performance rated.

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. 

Suitable for Water (Potable) Heating and Space Heating.

Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non-potable water heating appliance.

All propane heaters are equipped with a cast iron burner. To order a propane heater change suffix “BN” to “CX”.
For 10 year models, change suffix from “6” to “10”.
*Based on manufacturers rated recovery efficiency.
•Models feature optional top T&P location and must be specified when ordering.
Note: M-

I

-30S, M-

I

-50L, M-

I

-60T, M-

I

-75S and M-

I

-100T do not have top T&P option.

M-

I

-100T models feature hand hole cleanout.

Floor to space heating return for M-

I

-75S6BN 17

3

4

"/451mm,

M-

I

-100T6BN 17

5

8

"/448mm

Floor to space heating outlet for M-

I

-75S6BN 53"/1346mm,

M-

I

-100T6BN 505⁄8"/1286mm

E

C

B

A

D

F

8"

B

• Optional T&P

Location Dimension

“D” dimension listed

as side/top.

Printed in  U.S.A.

101-B-0108-A

©2008, Bradford White Corporation. All rights reserved.

Ambler, PA

For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.

Sales

800-523-2931 

Fax

215-641-1670 

/ Technical Support

800-334-3393 

Fax

269-795-1089 

Warranty

800-531-2111 

Fax

269-795-1089

International: 

Telephone

215-641-9400 

Telefax 

215-641-9750 / www.bradfordwhite.com

Sales / Technical Support

866-690-0961 

/

905-238-0100 

Fax 

905-238-0105 

/

www.bradfordwhite.com

Отзывы: