Condensing PDV Series

  

 

WARNING:

If the information in these

instructions is not followed exactly, a fire or

explosion may result causing property damage,

personal injury, or death.

FOR YOUR SAFETY

   Do not store or use gasoline or other flammable, 

combustible, or corrosive vapors and liquids in the 

vicinity of this or any other appliance.

IMPORTANT

Before proceeding, please inspect the

water heater and its components for

possible damage.

DO NOT

install any

water heater with damaged

components. If damage is evident

then please contact the supplier where

the water heater was purchased or the

manufacturer listed on the rating plate

for replacement parts.

 

 

 

 

 

 

 

WHAT TO DO IF YOU SMELL GAS: 

x

 

DO NOT try to light any appliance. 

x

 

DO NOT touch any electrical switch; do not use any 

         phone in your building. 

x

 

Immediately call your gas supplier from a neighbor's phone.  

Follow the gas supplier's instructions. 

x

 

If you cannot reach your gas supplier, call the fire 

 department. 

Installation and service must be performed by a qualified 

installer, service agency or the gas supplier. 

 

 

DANGER 

DO NOT store or use gasoline or other 

flammable, combustible, or corrosive vapors 

and liquids in the vicinity of this or any other 

appliance. 

 

WARNING 

DO NOT ATTEMPT TO LIGHT ANY GAS APPLIANCE IF YOU ARE 

NOT CERTAIN OF THE FOLLOWING: 

x

 

Liquefied petroleum gases/propane gas and natural gas 

have an odorant added by the gas supplier that aids in the 

detection of the gas. 

x

 

Most people recognize this odor as a “sulfur” or “rotten egg” 

smell. 

x

 Other conditions, such as “odorant fade” can cause the 

odorant to diminish in intensity, or “fade”, and not be as 

readily detectable. 

x

 

If you have a diminished sense of smell, or are in any way 

unsure of the presence of gas, immediately contact your gas 

supplier from a neighbor’s telephone. 

Gas detectors are available.  Contact your gas supplier, or plumbing 

professional, for more information. 

 

CAUTION 

Turn OFF or disconnect the electrical power supply to the water heater 

before servicing.  Label all wires prior to disconnection when servicing 

controls.  Wiring errors can cause improper and dangerous operation.  

Verify proper operation after servicing. 

 

WARNING 

FAILURE TO INSTALL AND MAINTAIN A NEW, LISTED ¾” X ¾” 

TEMPERATURE AND PRESSURE RELIEF VALVE WILL RELEASE 

THE MANUFACTURER FROM ANY CLAIM THAT MIGHT RESULT 

FROM EXCESSIVE TEMPERATURE AND PRESSURES. 

 

WARNING 

Water heaters are heat producing appliances.  To avoid damage 

or injury, do not store materials against the water heater or vent-

air intake system.  Use proper care to avoid unnecessary contact 

(especially by children) with the water heater and vent-air intake 

components.

  UNDER NO CIRCUMSTANCES SHOULD 

FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT 

THINNER BE USED OR STORED IN THE VICINITY OF THIS 

WATER HEATER, VENT-AIR INTAKE SYSTEM OR IN ANY 

LOCATION FROM WHICH FUMES COULD REACH THE 

WATER HEATER OR VENT-AIR INTAKE SYSTEM 

 

WARNING 

Hydrogen gas can be produced in an operating water heater that 

has not had water drawn from the tank for a long period of time 

(generally two weeks or more).  

Hydrogen gas is extremely 

flammable.

 To prevent the possibility of injury under these 

conditions, we recommend the hot water faucet to be open for 

several minutes at the kitchen sink before you use any electrical 

appliance which is connected to the hot water system. If 

hydrogen is present, there will be an unusual sound such as air 

escaping through the pipes as hot water begins to flow. DO NOT 

smoke or have open flame near the faucet at the time it is open.

 

 

CAUTION 

If sweat fittings are to be used DO NOT apply heat to the nipples 

on top of the water heater.  Sweat the tubing to the adapter 

before fitting the adapter to the water connections.  It is 

imperative that heat is not applied to the nipples containing a 

plastic liner.

 

3

Содержание LC2PDV50H76

Страница 1: ...1 19 SERVICE MANUAL Troubleshooting Guide and Instructions for Service To be performed ONLY by qualified service providers Models Covered by This Manual RC2PDV50H N X LC2PDV50H76 N X Denotes Warranty...

Страница 2: ...ent 17 II Pressure Switch Testing Replacement 18 III Blower Testing Replacement 20 IV Blower Temperature Switch Testing Replacement 22 V Gas Control Testing Replacement 24 VI Simulated Resistive Devic...

Страница 3: ...one Gas detectors are available Contact your gas supplier or plumbing professional for more information CAUTION Turn OFF or disconnect the electrical power supply to the water heater before servicing...

Страница 4: ...ases blower life by reducing bearing wear and noise Rugged Wiring Connections receptacle type connections promote error free wiring Increased Vent Lengths increased venting performance is achieved whi...

Страница 5: ...ls Required for Service Manometer A liquid U tube type or a digital magnahelic type can be used This device is used to measure gas and or air pressure and vacuum Multi Meter A digital type is strongly...

Страница 6: ...al 188 F 87 C Commercial 199 F 93 C Residential Temperature Set Point Range 60 F 16 C to 160 F 71 C approximate temperatures Commercial Temperature Set Point Range 80 F 27 C to 180 F 82 C approximate...

Страница 7: ...10 3 1 Through the Wall 2 110 33 5 10 3 1 Through the Wall 3 105 32 0 10 3 1 Through the Wall 4 100 30 5 10 3 1 Through the Wall 5 95 29 0 10 3 1 Through the Roof 0 120 36 6 15 4 6 Through the Roof 1...

Страница 8: ...d maximum 1 second minimum Post purge 15 Seconds PS Fault Delay failed open close Retry after 2 minutes Soft Lockout Retry after 5 minutes ECO Limit Lockout Indefinite see PV SERVICE PROCEDURE VI page...

Страница 9: ...with a 3 second pause The gas control waits 2 minutes and then the blower runs for 30 seconds This cycle repeats until the safety circuit opens 2 Blower energizes 3 Pressure Switch Proves Blower Vent...

Страница 10: ...9 Burner off 10 Blower post purges 15 seconds Abnormal Operation 1 Simulated Resistive Device Fault a If the resistance is greater than 70 000 ohms The gas control immediately turns off all outputs T...

Страница 11: ...turns off and the control flashes 3 times with a 3 second pause The gas control waits 2 minutes before turning on the blower for another 30 seconds to check if the circuit will close This cycle repea...

Страница 12: ...tion begins If the recycle count limit has been reached the gas control turns off the blower and flashes 6 times then 3 times with a 3 second pause The gas control waits 5 minutes before repeating the...

Страница 13: ...locked or restricted 3 Oxidation build up on pilot electrode 4 Wire damage to pilot assembly or bad connection at gas valve 5 Low gas pressure Page 17 Procedure II Two flash three second pause Pressur...

Страница 14: ...ed 3 Oxidation build up on pilot electrode 4 Wire damage to pilot assembly or bad connection at gas valve 5 Insufficient combustion air 6 Gas pressure is out of specification 1 4 Page 17 5 Refer to in...

Страница 15: ...lot flame should be stable Some causes for an unstable pilot flame are a The water heater vent is less than the allowable vent length b The gas pressure is out of specification c The pilot flame is no...

Страница 16: ...e the burner assembly from the combustion chamber Step 7 Thoroughly inspect the burner surface area and burner port area and remove any loose debris Step 8 Unscrew the burner from the main burner orif...

Страница 17: ...there is no continuity Step 10 Visually inspect the igniter flame sense electrode for deterioration Replace the pilot as necessary The electrode should not be in contact with the pilot hood If so car...

Страница 18: ...Y N Y Check tubing and pressure tap on switch for blockage Is there blockage Check tubing and pressure tap on switch for blockage Is there blockage Switch contacts are OK See Safety Circuit Voltage T...

Страница 19: ...m pressure switch see photo 5 Step 5 Disconnect the wire leads from the pressure switch see photo 6 Step 6 Reconnect the wires from Step 5 to the new pressure switch Step 7 Carefully position the pres...

Страница 20: ...here 115VAC at wall outlet Incorrect supply voltage polarity With blower running and exhaust adapter removed from the top of blower is there a negative pressure of 2 80 to 3 2 w c Repair or replace po...

Страница 21: ...on Step 1 Clean any debris from the jacket head of water heater Step 2 Set new blower with gasket in place using locating pins on blower flange to line up with location holes in jacket head Step 3 Sec...

Страница 22: ...r high exhaust temperatures Step 1 Vent length is below minimum allowable Step 2 Vent diameter not to specification Step 3 Missing or deteriorated flue baffle s Step 4 Gas pressure is out of specifica...

Страница 23: ...e switch to the blower housing see photo 14 Step 5 Remove the temperature switch from the blower housing Step 6 Install the new temperature switch Be sure the temperature switch is properly seated in...

Страница 24: ...ap Step 4 Follow instructions located on the lighting instructions label and proceed to light the main burner and observe manometer reading Step 5 Proper operating range for Natural Gas is 4 0 0 5 w c...

Страница 25: ...he gas control to the LOW position and wait a minimum of 6 seconds Then rotate the gas control knob to the desired setpoint at least a 45 rotation and follow the lighting instructions to return to nom...

Страница 26: ...to damage gasket material in inner door Step 7 Removal of Gas Control a Disconnect main burner feedline and pilot tube b Remove the gas control from water heater by rotating counter clockwise DO NOT...

Страница 27: ...interfere with the outer jacket burner access door when reinstalled f Firmly place right side inner door flange against the left side inner door flange and secure with 2 hex drive screws from Step 6b...

Страница 28: ...ant Step 3 Using a multi meter set to the ohms setting check resistance of the flammable vapor sensor or simulated resistive device Resistance must be between 3 000 ohms and 48 000 ohms If outside of...

Страница 29: ...es not light observe the LED flash code on the gas control and refer to the troubleshooting section see page 13 Safety circuit voltage is OK Is there 10 to 13 VAC between the pressure switch terminal...

Страница 30: ...gas control Disconnect wire harness from gas control see photo 21 Is there 115VAC across black white wires as shown in photo 22 Incorrect supply voltage polarity Is there 115VAC across pins 2 6 Call f...

Страница 31: ...Visually inspect the inlet nipple diptube The inlet nipple diptube should be free of cracks and any blockage The HydroJet slots should be open and free of any blockage Any damage such as cracks restri...

Страница 32: ...6 socket is necessary to loosen the anode Step 6 Remove the anode and visually inspect the anode Step 7 If the anode does show signs of depletion this is normal a If depletion is of the original anode...

Страница 33: ...r Step 8 Remove the jacket head screws with a nutdriver Remove the jacket head This may require assistance with a slotted screwdriver as shown below Step 9 With the jacket head removed cut the perimet...

Страница 34: ...head in place by screwing in the screws removed in Step 7 Step 17 Reinstall the blower on the jacket head There are holes in the jacket head to accept locating pins on the underside of the blower hous...

Страница 35: ...ired If replacement is required proceed to Inner Door Gasket Replacement Procedure Inner Door Gasket Replacement Procedure Step 1 After inspection of the inner door as noted in Step 4 completely remov...

Страница 36: ...channel of the inner door around the feedline Using the hex drive screws from Step 3c secure the left side inner door in place DO NOT OVER TIGHTEN SCREWS Step 3 Position pilot tube and igniter sensor...

Страница 37: ...the fastener holes of the combustion chamber are aligned with right side inner door slotted opening Verify seal integrity around combustion opening Secure right side inner door using hex drive screws...

Страница 38: ...g the condensate tee to the back cover and the vertical vent pipe Step 4 Remove the condensate tee Be aware that condensate is in the tee and take appropriate measures Step 5 Remove the bottom cap of...

Страница 39: ...t on the exhaust cover Step 3 With a 5 16 socket or wrench loosen the 8 screws sealing the cover to the gasket Step 4 Remove the cover and inspect the seal bead on the gasket flange as well as the sea...

Страница 40: ...Hand start the nuts that were removed in step 3 onto the studs on all 8 locations to ensure a proper fit Begin securing the 5 16 nuts with an wrench or a socket This process should be done following...

Страница 41: ...xhaust Cover 37 Pilot 5 Blower Temp Switch 16 Hex Head Anode 27 Condensate Tee 38 Screw 6 Jacket Head 17 Vertical Exh Pipe 28 Exhaust Gasket 39 Feedline 7 Surround 18 Vertical Int Pipe 29 Right Side I...

Страница 42: ......

Страница 43: ......

Страница 44: ......

Отзывы: