STEP THREE: 
 

In the brass outlet fitting there is a flow restrictor, this is a little black plug.   
Shut the water off to the unit and then remove the plug from the fitting.  Open 
the faucet fully to see if the light illuminates with water flowing through the 
unit.

 

  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

0.5 gpm flow regulator
(The little black plug)

INLET

OUTLET

SP MODELS

UP

inlet filter

 
 
 

If the unit now operates with water flowing, call Technical Service at  
1-800-334-3393. Describe what actions were taken and a selection of “flow 
restrictors” will be sent to you to replace the one that was removed. This will allow 
the unit to operate, but will also control the flow rate to provide the correct rise in 
temperature.

 

 

 

If the unit still does not work proceed to step 4. 

 

 

 

 

 

Содержание ES-2400-1-S-10

Страница 1: ...8V ES 3500 4 S 10 240V ES 4100 5 S 10 277V ES 3000 5 S 10 277V All information necessary to troubleshoot this water heating unit is contained in this fully illustrated guide If problems still exist af...

Страница 2: ...ectly on the wall Any other mounting configuration will prevent the unit from operating properly If the unit is mounted correctly and still does not produce hot water look to see if the indicator ligh...

Страница 3: ...gpm Measure the flow rate using the following procedure Fill a 1 gallon milk container and using only water from the hot water outlet record the time In seconds required to fill To calculate flow rat...

Страница 4: ...5 gpm flow regulator The little black plug INLET OUTLET SP MODELS UP inlet filter If the unit now operates with water flowing call Technical Service at 1 800 334 3393 Describe what actions were taken...

Страница 5: ...ng is less then 20 ohms on the single Rx1 scale or the Rx10 scale then the element is good if it is much greater e g 10 000 ohms or if you get a reading on the Rx1k you will need to replace the elemen...

Страница 6: ...ater is attached to the faucet these are integral for proper performance of the unit If the special aerator is not included call Technical Service at 1 800 334 3393 and one will be shipped to you BE C...

Страница 7: ...ounting holes for the PCB on an ES EFC or EFT model Board mounted in correct position Inlet filter STEP TWO Inspect the inlet filter See diagram above for location Make sure the inlet filter screen is...

Отзывы: