The indicator light does not illuminate (When the hot water faucet is fully 

opened): 

 

STEP ONE: 
 

Is the circuit breaker switched ON at the main circuit breaker panel? 
 
YES   

 

Go to Step two 

    

NO 

Run water at the hot water faucet, for a couple 
of minutes, before turning on the circuit 
breaker. Then turn on the circuit breaker at the 
main circuit breaker panel.

   

 

STEP TWO:  
 

The unit will not heat unless sufficient water is flowing through the unit. 
The minimum acceptable flow rate is about 0.5 gallons per minute (1/2 
gpm). Measure the flow rate using the following procedure: 
 
Fill a 1-gallon “milk” container and, using only water from the hot water 
outlet, record the time (In seconds) required to fill. To calculate flow 
rate, divide the number of gallons the container holds (In this case one 
gallon) by the time required to fill.  

 

 

 

 
e.g. If it takes 87 seconds to fill the container the flow rate would be: 
Flow rate(gpm) = v/t x 60 = (1 gallon/87 sec.) x (60 sec./1 min.) = .69 gpm 
 
Now, run the water with the faucet open fully.  If the indicator light still does not 
illuminate, then proceed to STEP THREE.

 

 

 

Aerator - Fits on the orifice of the faucet. 
 

 
 
 
 
 
 
 

 

Male/female threaded adapter on top of 
aerator. 

Flow restrictor - (may be removed to 
increase flow) 

Содержание ES-2400-1-S-10

Страница 1: ...8V ES 3500 4 S 10 240V ES 4100 5 S 10 277V ES 3000 5 S 10 277V All information necessary to troubleshoot this water heating unit is contained in this fully illustrated guide If problems still exist af...

Страница 2: ...ectly on the wall Any other mounting configuration will prevent the unit from operating properly If the unit is mounted correctly and still does not produce hot water look to see if the indicator ligh...

Страница 3: ...gpm Measure the flow rate using the following procedure Fill a 1 gallon milk container and using only water from the hot water outlet record the time In seconds required to fill To calculate flow rat...

Страница 4: ...5 gpm flow regulator The little black plug INLET OUTLET SP MODELS UP inlet filter If the unit now operates with water flowing call Technical Service at 1 800 334 3393 Describe what actions were taken...

Страница 5: ...ng is less then 20 ohms on the single Rx1 scale or the Rx10 scale then the element is good if it is much greater e g 10 000 ohms or if you get a reading on the Rx1k you will need to replace the elemen...

Страница 6: ...ater is attached to the faucet these are integral for proper performance of the unit If the special aerator is not included call Technical Service at 1 800 334 3393 and one will be shipped to you BE C...

Страница 7: ...ounting holes for the PCB on an ES EFC or EFT model Board mounted in correct position Inlet filter STEP TWO Inspect the inlet filter See diagram above for location Make sure the inlet filter screen is...

Отзывы: