background image

TROUBLESHOOTING GUIDE

 

ELECTRIC INSTANTANEOUS TANKLESS WATER HEATER 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

Single Point

 

“ES”- MODELS

 

ES-2400-1-S-10  

120V 

ES-3000-1-S-10  

120V 

ES-3500-1-S-10  

120V 

ES-3000-3-S-10  

208V 

ES-4100-2-S-10  

208V 

ES-3500-4-S-10  

240V 

ES-4100-5-S-10  

277V 

 
 
 
 
 
 

ES-3000-5-S-10  

277V

 

 

All information necessary to troubleshoot  

 

this water heating unit is contained in this fully 

 
 

illustrated guide. If problems still exist after 

 reading and carrying out the instructions in 

this 

 
 
 
 
 

m

toll free number below for assistance. 

PH

 1-800-334-3393 

anual, contact Technical Service at the 

 

 

ONE TOLL FREE

 

 

238-43141-00  Rev. 5/02 

Содержание ES-2400-1-S-10

Страница 1: ...8V ES 3500 4 S 10 240V ES 4100 5 S 10 277V ES 3000 5 S 10 277V All information necessary to troubleshoot this water heating unit is contained in this fully illustrated guide If problems still exist af...

Страница 2: ...ectly on the wall Any other mounting configuration will prevent the unit from operating properly If the unit is mounted correctly and still does not produce hot water look to see if the indicator ligh...

Страница 3: ...gpm Measure the flow rate using the following procedure Fill a 1 gallon milk container and using only water from the hot water outlet record the time In seconds required to fill To calculate flow rat...

Страница 4: ...5 gpm flow regulator The little black plug INLET OUTLET SP MODELS UP inlet filter If the unit now operates with water flowing call Technical Service at 1 800 334 3393 Describe what actions were taken...

Страница 5: ...ng is less then 20 ohms on the single Rx1 scale or the Rx10 scale then the element is good if it is much greater e g 10 000 ohms or if you get a reading on the Rx1k you will need to replace the elemen...

Страница 6: ...ater is attached to the faucet these are integral for proper performance of the unit If the special aerator is not included call Technical Service at 1 800 334 3393 and one will be shipped to you BE C...

Страница 7: ...ounting holes for the PCB on an ES EFC or EFT model Board mounted in correct position Inlet filter STEP TWO Inspect the inlet filter See diagram above for location Make sure the inlet filter screen is...