background image

 
 

 
 
 
 
 
 
 
 
 
 

V

A

 STEP THREE: 

 

      A multimeter / voltmeter is required 

to perform the following test. 

 
 
 
 

 

 
 

DANGER! 

TURN OFF THE CIRCUIT BREAKER BEFORE 

PROCEEDING WITH THE NEXT TESTS. 

 

Set the meter to the single ohms setting 
Do not measure continuity, this will not work. 

 
 

The Ohm Symbol 
(The upside down horseshoe) 

 
 

NOTE: BE SURE THE ELECTRICITY IS TURNED OFF TO THE UNIT

 

 

Remove the front cover of the unit.  At the end of the black heater body there are 
two threaded silver rods with brass nuts on them (Where the wires connect). Take a 
reading of the ohms value between these two rods and write it down (See the figure 
below). 

If the reading is less then 20 ohms on the single  
(Rx1) scale or the (Rx10) scale then the 
element is good, if it is much greater.  
e.g. 10,000 ohms or if you get a reading on the 
(Rx1k), you will need to replace the element.  
To do this contact Technical Service at 1-800-
334-3393 for replacement elements (Please 
write down the resistance value, before 
contacting Technical Service, this will be very 
helpful to us.  Also have the order ref. and the 
serial numbers of the unit available for 
Technical Service). 

 

Отзывы: