The indicator light does not illuminate (When the hot water faucet is 
fully opened): 

 

STEP ONE: 
 
Is the circuit breaker switched ON at the main circuit breaker panel? 
   

YES                   Go to Step two 

 
    

NO  

Run water at the hot water faucet, for a couple 
of

 

minutes, before turning on the circuit breaker.  

Then turn on the circuit breaker at the main 
circuit breaker panel.

   

 

 

STEP TWO:  
 
The unit will not heat unless sufficient water is flowing through the unit. 
 

The minimum acceptable flow rate is 0.55 gallons per minute.  Some 
models require a higher flow rate, see chart below for specific model 
flow rates. Measure the flow rate using the following procedure. 
 
 

Fill a 1-gallon “milk” container and, using only water from the hot water outlet, record 
the time (In seconds) required to fill. To calculate the flow rate, divide the number of 
gallons the container holds (In this case one gallon) by the time required to fill. 

 

e.g. If it takes 87 seconds to fill the container then the flow rate would be: 
Flow rate (gpm) = v/t x 60 = 1 gal./87 sec. x 60 sec./1 min. = .69 gpm 
 
Open all water valves completely. If the indicator light still does not illuminate then 
proceed to STEP THREE. 

 

 
 
 
 
 
 
 
 

MODEL TYPE / ORDER REF. #                   MINIMUM FLOW RATE 
 
EFC-5500-4-S-10, EFC-6500-4-S-10  

0.55 

GPM 

 
EFC-7500-4-S-10, EFC-8000-5-S-10,    

 

EFC-8300-2-S-10 

    0.65 

GPM 

 
EFC-9000-5-S-10, EFC-9500-4-S-10, 
EFC-10000-5-S-10                                             0.75 GPM

   

 

 