Service Procedure I: 

Thermostat Circuit Testing and Replacement

 

 

APPENDIX-A 

Sensor Resistance at Various Temperatures 

 

Be careful when making voltage measurements or jumping terminals not to damage or deform 

connectors or connector pins

 

Draw water from the temperature and pressure relief valve. Compare temperature with temperature ohms chart below. 

 

Example:

 If the temperature is 84°F, then the resistance through the sensor would be 8449 (see shaded area). 

Note:

 Sensor resistance increases as the temperature falls. 

 

In Degrees F 

°F 

40 

26109 

25400 

24712 

24045 

23399 

22771 

22163 

21573 

21000 

20445 

50 

19906 

19383 

18876 

18383 

17905 

17440 

16990 

16553 

16128 

15715 

60 

15314 

14925 

14548 

14180 

13823 

13477 

13140 

12812 

12494 

12185 

70 

11884 

11592 

11308 

11032 

10763 

10502 

10248 

10000 

9760 

9526 

80 

9299 

9078 

8862 

8653 

8449 

8250 

8057 

7869 

7685 

7507 

90 

7333 

7165 

7000 

6839 

6683 

6531 

6383 

6238 

6098 

5961 

100 

5827 

5697 

5570 

5446 

5326 

5208 

5094 

4982 

4873 

4767 

110 

4663 

4562 

4464 

4368 

4274 

4183 

4094 

4006 

3922 

3839 

120 

3758 

3679 

3602 

3527 

3453 

3382 

3312 

3244 

3177 

3112 

130 

3048 

2986 

2925 

2866 

2808 

2752 

2697 

2643 

2590 

2538 

140 

2488 

2439 

2391 

2344 

2298 

2253 

2209 

2166 

2124 

2083 

150 

2043 

2004 

1966 

1928 

1891 

1856 

1820 

1786 

1753 

1720 

160 

1688 

1656 

1625 

1595 

1566 

1537 

1509 

1481 

1454 

1427 

170 

1402 

1376 

1351 

1327 

1303 

1280 

1257 

1235 

1213 

1191 

180 

1170 

1150 

1129 

1110 

1090 

1071 

1053 

1035 

1017 

999 

190 

982 

965 

949 

933 

917 

901 

886 

871 

857 

842 

200 

828 

814 

801 

788 

775 

762 

749 

737 

725 

713 

 

In Degrees C 

°C 

32648 

31026 

29495 

28049 

26682 

25389 

24166 

23010 

21915 

20879 

10 

19898 

18968 

18088 

17253 

16461 

15710 

14998 

14322 

13680 

13071 

20 

12492 

11942 

11419 

10922 

10450 

10000 

9572 

9165 

8778 

8409 

30 

8057 

7722 

7403 

7099 

6808 

8532 

6268 

6016 

5775 

5546 

40 

5327 

5117 

4917 

4726 

4543 

4368 

4201 

4042 

3889 

3742 

50 

3602 

3468 

3340 

3217 

3099 

2986 

2878 

2774 

2675 

2579 

60 

2488 

2400 

2316 

2235 

2157 

2083 

2011 

1942 

1876 

1813 

70 

1752 

1693 

1637 

1582 

1530 

1480 

1432 

1385 

1340 

1297 

80 

1256 

1216 

1177 

1140 

1105 

1070 

1037 

1005 

974 

944 

90 

916 

888 

861 

835 

810 

786 

763 

741 

719 

698 

 

 

 

21

Содержание EF120T4003N3

Страница 1: ...ICE MANUAL Troubleshooting Guide and Instructions for Service To be performed ONLY by qualified service providers Models Covered by This Manual EF120T4003N A 3 EF120T5003N A 3 Commercial Ultra High Ef...

Страница 2: ...Service Procedure IV Gas Valve Replacement 29 Service Procedure V Blower Testing and Replacement 30 Service Procedure VI Blocked Vent Pressure Switch Testing and Replacement 32 Service Procedure VII...

Страница 3: ...agnostic information both on the control board and digital display to help in determining the cause of system lockouts The contents in this manual are detailed informational tools to assist in the pro...

Страница 4: ...Phillips head screw driver 2 tip 1 4 in nut driver pliers common needle nose socket set including a 1 1 16 deep well socket wire cutters wire strippers wire crimpers torpedo level small shop vac step...

Страница 5: ...e Open Shipping Wt LBS 120T400 399 999 119 71 73 1 1 1 1 1120 120T500 499 999 119 71 74 7 8 1 1 1 1 1135 DIMENSIONS MILLIMETERS Model No Input Rate KW Storage Capacity Liter A Height B Floor to Alt Ho...

Страница 6: ...24 volts Temperature range 100 to 183 F Used to set tank temperature F or C show operating status display error codes error code history and limit maximum setpoint temperature Control Board Operates o...

Страница 7: ...l of all elbows and straight pipe intake and exhaust must not exceed maximum lengths from tables above Example A 4 in balanced direct vent system has 10 ft of straight exhaust pipe and 10 ft of straig...

Страница 8: ...ccur the digital display with flash error code 137 pressure switch is open or vent safety switch is open while the unit is waiting to restart 5 minutes the normal sequence of operation 6 Once the flam...

Страница 9: ...al display The control board can only be reset in the Service Mode which is detailed in the Troubleshooting section of this Service Manual pg 11 3 ERROR CODE 67 a If the exhaust terminal becomes block...

Страница 10: ...factory installed A full installation operation and troubleshooting manual is provided with the gateway kit CAUTION Before beginning any Troubleshooting operations listed below please note that the g...

Страница 11: ...al display operates see next page Check main power supply to water heater Check fuse circuit breaker plug receptacle line cord and wiring to water heater Check to make sure switch on front of control...

Страница 12: ...ying temperature sensors Does blower post purge for 30 seconds System O K Check to see if digital display shows any other error codes 67 pressure switch 67 vent safety switch or 80 high limit If so re...

Страница 13: ...oamps when the burner is operating Step 3 Press the lower right Next button and the digital display will flash and show the number of any alert codes If alerts are present and the unit is not operatin...

Страница 14: ...wer right Next button and the digital display will show the manual firing rate adjustment This function is not currently used Any adjustment made has no effect Step 7 End of screens in Service Mode Pr...

Страница 15: ...ears on the display Step 2 Press DONE button for new setting to take effect immediately If the DONE button is not pressed the new temperature setting will take effect in approximately 10 seconds To De...

Страница 16: ...isplay from q qF to q qC or C to F Enter Set Up Mode by pressing both UP DOWN buttons together for 3 seconds NOTICE Pressing the NEXT button instead of DONE will enter the display to show unused scree...

Страница 17: ...quency voltage and VA meet the specifications See Service Procedure X Transformer Replacement pg 40 53 Reverse polarity x Check the control board and digital display connections x Check the control bo...

Страница 18: ...wires and that there is no moisture on the flame sensor x If problem persists and all other checks have been verified replace the control board 110 Ignition failure occurred x Burner failed to light...

Страница 19: ...ensor if needed Turn power ON to water heater Run water heater through heating cycle and verify proper operation Sensor temperature can be viewed when burner shuts off see section on viewing the digit...

Страница 20: ...ay be reset x Reconnect and switch on power to the water heater x Press button under Reset and hold for 3 seconds x Set thermostat to the desired setting x Water heater will start x Monitor temperatur...

Страница 21: ...26 5208 5094 4982 4873 4767 110 4663 4562 4464 4368 4274 4183 4094 4006 3922 3839 120 3758 3679 3602 3527 3453 3382 3312 3244 3177 3112 130 3048 2986 2925 2866 2808 2752 2697 2643 2590 2538 140 2488 2...

Страница 22: ...stall new sensor completely into well and reinstall sensor clip 8 Connect temperature sensor to control 9 Fold insulation back into place Be sure there are NO wires in contact with burner 10 Restore 1...

Страница 23: ...s it stable between 7 14 W C static heater not running See images on page Is gas supply pressure regulator adjustable to maintain proper and stable setting Inadequately sized regulator Adjust gas supp...

Страница 24: ...urner tube see Burner Tube Inspection pg 27 Does the burner stay lit Does the burner operate normally until thermostat is satisfied Call Technical Support System O K Y Y Y Y Y N N N N Y Y Y Y N Refer...

Страница 25: ...harness 6 Disconnect flame sensor and blower wire harnesses Disconnect high voltage cable from spark rod connection 7 Remove the 5 bolts 1 2 socket holding the burner mounting insert in place 8 Caref...

Страница 26: ...Secure combustion assembly at the burner mounting insert using screws from Step 6 on previous page Tighten bolts evenly 3 Reconnect high voltage cable to spark rod flame sensor blower and gas valve 4...

Страница 27: ...e spark rod and flame sensor in place long reach magnetic Phillips head screwdriver Carefully remove spark rod and flame sensor from combustion assembly 8 Remove the 4 nuts 7 16 wrench holding the bur...

Страница 28: ...are NOT affected by any of the above gasket replacement is not required 2 Install burner tube with gaskets into burner mounting insert Be sure gasket surfaces are free of debris 3 Reconnect the blowe...

Страница 29: ...erial from blower and venturi mounting flange 8 Install new gas valve with new gasket provided Secure gas valve in place using screws from Step 6 9 Reconnect gas supply intake venting wire harness and...

Страница 30: ...Blower Replacement Procedure pg 31 Are collector high limit switch and pressure switches in normally closed Correct safety circuit problem per safety circuit trace see Blocked Vent Pressure Switch Tes...

Страница 31: ...om venturi mounting flange and transition flange 10 Install new blower with new gasket provided Secure blower in place using screws from Step 8 11 Reconnect gas valve assembly to blower with new gaske...

Страница 32: ...Procedure pg 41 Check digital display Is it on within 5 minutes Pressure switch is O K Is the display flashing after 5 minutes Is error code 67 present again Call Technical Support Check blower for pr...

Страница 33: ...o correct blockage below Replace blocked exhaust vent switch see Blocked Exhaust Vent Switch Testing and Replacement pg 32 With ohmmeter check pressure switch for continuity Contacts should be closed...

Страница 34: ...tch mounting screws 5 16 nut driver and remove pressure switch common screwdriver 6 Assemble new pressure switch to heater using screws from Step 5 7 Reconnect red wire leads Note Wire leads are inter...

Страница 35: ...or wire lead see Flame Sensor Replacement Procedure pg 36 Remove flame sensor from water heater Check continuity from tip of flame sensor to end of wire lead Is there continuity Is flame sensor free o...

Страница 36: ...any residual gasket material from transition base flange 8 Install new flame sensor with new gasket provided using screws from Step 6 Arrange flame sensor with hook towards burner 9 Reconnect the fla...

Страница 37: ...ages below 4 Clean spark rod with steel wool or emery cloth 5 Re measure and verify spark gap are between 3 16 to 1 4 after bending 6 Verify the integrity of all gaskets and replace where required 7 R...

Страница 38: ...Combustion System Removal Procedure and verify spark gap following Spark Rod Gap Inspection and Adjustment Reassemble combustion system following Combustion System Replacement Procedure 10 Fold insula...

Страница 39: ...n the top back side of the control board first 7 Tilt the control board and slide control board hook tabs from slots in the metal panel see images below 8 Replace the control board and all wire connec...

Страница 40: ...ace and remove transformer from control board see image below 6 Install new transformer and secure in place with screws from Step 6 7 Reconnect primary and secondary wires to the transformer leads are...

Страница 41: ...y across high limit switch see image below Does the water heater function Call Technical Support Replace vent safety switch see Vent Safety Switch Replacement Procedure pg 41 Reset heater observe heat...

Страница 42: ...ow 4 Disconnect grey wire leads from vent safety switch see image below 5 Remove the 2 switch mounting screws Phillips screwdriver and remove switch from heater 6 Install a new switch using screws fro...

Страница 43: ...wered anode system is disconnected 1 Check the power supply or wire connections to the powered anode control 120 VDC 2 Indicator light diagnostic codes a If the LED is flashing red then there is a mal...

Страница 44: ...heater and using a common condensate line make sure the condensate line is properly sized Service Mechanical Room Provide adequate space for servicing heater Leave room to get to the bottom safety sw...

Страница 45: ...____________________ Is trap provided Y or N _________________________ Exhaust Collector Pressure Inches W C ___________________________ Combustion CO2 ____________________ CO ____________________ Ins...

Страница 46: ...___________________________________________ ____________________________________________________________ ____________________________________________________________ __________________________________...

Страница 47: ...________________________________ _____________________________________________________________________ _____________________________________________________________________ ___________________________...

Страница 48: ......

Отзывы: