TROUBLESHOOTING GUIDE
PROBLEM CAUSE
SOLUTION
ECO on thermostat tripped
Determine if ECO trip is a result of excessive solar heat or
electric element. Correct or replace as necessary. Depress red
“RESET” button on thermostat .
Improper thermostat setting
or calibration
Adjust tank thermostat to appropriate setting
See Section VII.
Check electrical connections.
Check that proper valves are open.
Check that system is bled.
Circulator does not pump
fluid through solar collector
Replace as necessary.
Check fuse and replace.
Check circuit breaker and reset (if applicable).
Electrical problem (Control,
wiring, etc.)
Check power supply.
Scale build-up
If solar controller, collectors, circulator, and tank are operating
satisfactorily, coil may have scale coating. See Section VIII:
Maintenance.
No hot water at
faucet
Clogged cold water filter
Clean or replace filter or strainer.
Thermostat set too high
Adjust thermostat setting. See Section VII.
Improper system plumbing
Compare plumbing to Section V.
Improper system wiring
Compare wiring to Section VI.
Water at faucet
too hot
Mixing Device temperature
set too high
Adjust ASSE approved thermostatic mixing valve setting. Refer
to ASSE approved thermostatic mixing valve instructions.
Thermostat setting too low
Adjust thermostat to higher setting. See Section VII.
Undersized solar collectors
Review calculations for proper collector surface area,
orientation and available sunlight.
Faulty solar sensor or solar
controller
Check connections, power and sensor resistance. Replace as
necessary.
Peak use of hot water is
greater than tank storage
capacity
Determine peak usage and compare to tank capacity.
Check electrical connections.
Check that proper valves are open.
Check that system is bled.
Circulator does not pump
fluid
Replace as necessary.
Insufficient hot
water
Faulty tank thermostat
Replace thermostat.