Technical Characteristics

 

 

Type 

BW200-R 

BW300-R 

Capacity 

200 L 

300 L 

Water Pressure 

1MPa 

(10 bar) 

Net Weight (empty) 

26 kg 

32 kg 

Connections to the 
water supply network 

3/4” NPT 

Temperature Range 

32 to 66 °C 

 

Phase 

Single (1PH) 

Model 

BW200-
R1NCPP 

BW200-
R1NCWW 

BW200-
R1NCZZ 

BW300-
R1NCPP 

BW300-
R1NCWW 

BW300-
R1NCZZ 

Operation 

Non-simultaneous 

Nominal 
Power 

– 

Upper 
Heating 
Element 
(W) 

-/3000 

3500/ 

4500 

4500/ 

6000 

-/3000 

3500/ 

4500 

4500/ 

6000 

Nominal 
Power 

– 

Lower 
Heating 
Element 
(W) 

-/3000 

3500/ 

4500 

4500/ 

6000 

-/3000 

3500/ 

4500 

4500/ 

6000 

Nominal 
Voltage 
(VAC) 

240 

208/ 

240 

208/ 

240 

240 

208/ 

240 

208/ 

240 

 

Phase

 

Three (3PH) 

Model

 

BW200-R3SGPP 

BW300-R3SGWW 

BW200-R3SGZZ 

Operation

 

Simultaneous 

Nominal Power 

– 

Upper Heating 
Element (W)

 

3000 

4500 

6000 

Nominal Power 

– 

Lower Heating 
Element (W)

 

3000 

4500 

6000 

Nominal Voltage 
(VAC)

 

415 

 
 

 

Содержание BW200-R

Страница 1: ...THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGE RESULTING FROM FAILURE TO COMPLY WITH THESE INSTRUCTIONS READ THESE INSTRUCTIONS THOROUGHLY BEFORE STARTING For your family s comfort...

Страница 2: ...ed upon the nameplate located on the side of the water heater The water heater may be connected to water and electric power supply only by a qualified specialist Important All plumbing connections mus...

Страница 3: ...tion of this water heater should be contacted to inspect the appliance and to replace any part of the control system including thermostat which has been submerged in water Make sure that the rating pl...

Страница 4: ...ss the installation is such to eliminate the probable ignition of gasoline or flammable vapors The location of this water heater is of the utmost importance Before installing the water heater select a...

Страница 5: ...als calcium or sodium chloride waxes and process chemicals These materials are corrosive at very low concentration levels with little or no odor to reveal their presence NOTE DAMAGE TO THE WATER HEATE...

Страница 6: ...6 Installation continued Figure 1 Water Heater Dimensions A mm B mm C mm D mm E mm F mm G mm BW200 R 1201 1165 533 216 267 555 203 BW300 R 1631 1595 560 231 280 582 203...

Страница 7: ...BW300 R1NCZZ Operation Non simultaneous Nominal Power Upper Heating Element W 3000 3500 4500 4500 6000 3000 3500 4500 4500 6000 Nominal Power Lower Heating Element W 3000 3500 4500 4500 6000 3000 350...

Страница 8: ...ater are color coded The supply of cold water is marked with a blue ring The outlet of warm water is marked with a red ring Figure 2 Water Connections If this water heater is installed in a closed wat...

Страница 9: ...he maximum working pressure of the water heater The combination temperature and pressure relief valve shall also have an hourly rated temperature steam BTU discharge capacity not less than the hourly...

Страница 10: ...SCALDS 120 F 49 C More than 5 minutes 125 F 52 C 1 to 2 minutes 130 F 54 C About 30 seconds 135 F 57 C About 10 seconds 140 F 60 C Less than 5 seconds 145 F 63 C Less than 3 seconds 150 F 66 C About...

Страница 11: ...heater wired at the factory to comply with existing area codes but local utility codes may require or allow other circuitry Consult your local power company to determine the correct electrical hook u...

Страница 12: ...r light indicator L1 Live Conductor N Neutral Conductor WARNING WARNING WATER HEATER EQUIPED FOR LIMITED RANGE OF VOLTAGE This water heater is equipped for determinate range voltage 208 240 VAC or 415...

Страница 13: ...indicator 4b Lower light indicator L1 Live Conductor L2 Live Conductor L3 Live Conductor SAFETY SHUT OFF Water heaters have a bipolar safety thermostat that works in case of abnormal heating of water...

Страница 14: ...supply to the water heater Consult the plumbing professional or electric company in your area for service 2 Close the cold water supply shut off valve 3 Open the drain valve if provided on the water...

Страница 15: ...screw on the side of the electric water heater Align markings on thermostat and adjustment screw to desired water temperature Figure 5 Setting the Water Temperature DANGER Hotter water increases the...

Страница 16: ...r heater is not in use for longer periods of time it should be protected from freezing by setting the temperature to minimum possible position Do not disconnect the power Should you choose to disconne...

Страница 17: ...uggested below In some installations the maintenance interval may be more frequent depending on the amount of use and the operating conditions of the water heater Regular inspection and maintenance of...

Страница 18: ...de rod hot water outlet nipple has been installed to extend tank life The anode rod should be inspected periodically every 2 years and replaced when necessary to prolong tank life Water conditions in...

Страница 19: ...ate of the water heater For faster and better service please provide the part name model and serial number s of the water heater s when ordering parts READ THE WARRANTY FOR A FULL EXPLANATION OF THE L...

Страница 20: ...20 NOTES...

Отзывы: