13
Electrical Connections continued-
Figure 4B: 3 Phase, Simultaneous
Legend
1
Connection box
2a
Upper thermostat with bipolar
safety thermostat
2b
Lower thermostat with bipolar
safety thermostat
3a
Upper heating element
3b
Lower heating element
4a
Upper light indicator
4b
Lower light indicator
L1
Live Conductor
L2
Live Conductor
L3
Live Conductor
SAFETY SHUT-OFF
Water heaters have a bipolar safety thermostat that works in case of abnormal
heating of water. The operation of safety thermostat causes automatic opening of
the circuit the electrical heating element, whose resetting is manual, and must be
done after the elimination of the cause of the anomaly. If this anomaly occurs,
call an authorized service center.
Содержание BW200-R
Страница 20: ...20 NOTES...