Locating The Water Heater continued- 

 

DO NOT locate the water heater where water lines could be subjected 
to freezing temperatures.  Locate the water heater so that access 
panels and drain valves are accessible. 

Some models are not equipped 

with a drain valve. For those models, install a drain tee in the cold water inlet 
as close as practical to the water heater. 

 

Water heater corrosion and component failure can be caused by the heating 
and breakdown of airborne chemical vapors.  Examples of some typical 
compounds that are potentially corrosive are: spray can propellants, cleaning 
solvents, refrigerator and air conditioning refrigerants, swimming pool 
chemicals, calcium or sodium chloride, waxes and process chemicals.  
These materials are corrosive at very low concentration levels with little or no 
odor to reveal their presence.  

NOTE: DAMAGE TO THE WATER HEATER CAUSED BY EXPOSURE TO 
CORROSIVE VAPORS IS NOT COVERED BY THE WARRANTY.  DO 
NOT OPERATE THE WATER HEATER IF EXPOSURE HAS OR WILL 
OCCUR.  DO NOT STORE ANY POTENTIALLY CORROSIVE 
COMPOUNDS IN THE VICINITY OF THE WATER HEATER. 
 

This water heater must be located in an area where leakage of the tank or 
water line connections and the combination temperature and pressure relief 
valve will not result in damage to the area adjacent to the water heater or to 
lower floors of the structure.  When such locations cannot be avoided, a 
suitable drain pan must be installed under the water heater.  The drain pan 
must have a minimum length and width of at least 4 in. (10.2 cm) greater 
than the diameter of the water heater. The drain pan, as described above, 
can be purchased from your plumbing professional.  The drain pan must be 
piped to an adequate drain.  The piping must be pitched for proper drainage. 
 
To comply with NSF requirements this water heater is to be: 

a)  Sealed to the floor with sealant, in a smooth and easily cleanable 

way, or 

b)  Installed with an optional leg kit that includes legs and/or extensions 

that provide a minimum clearance of 6” beneath the water heater. 

 

Note: For California installation this water heater must be braced, 
anchored, or strapped to avoid falling or moving during an 
earthquake.  See instructions for correct installation procedures.  
Instructions may be obtained from California Office of the State 
Architect, 400 P Street, Sacramento, CA 95814. 

 

Содержание 238-44422-00G

Страница 1: ...HESE INSTRUCTIONS READ THESE INSTRUCTIONS THOROUGHLY BEFORE STARTING For your family s comfort safety and convenience it is recommended this water heater be installed and serviced by a plumbing professional A Spanish language version of these instructions is available by contacting the manufacturer listed on the rating plate La version espanola de estas instruccions se puede obtener al escribirle ...

Страница 2: ...r new Electric Water Heater We strongly recommend that you contact a plumbing professional for the installation of this water heater We require that you carefully read this manual as well as the enclosed warranty and refer to it when questions arise If you have any specific questions concerning your warranty please consult the plumbing professional from whom your water heater was purchased For you...

Страница 3: ...rtified for the purpose of heating potable water The installation and use of this water heater for any purpose other than the heating of potable water may cause damage to the water heater and create a hazardous condition and nullify the warranty Do not use this appliance if any part has been submerged in water The plumbing professional responsible for the installation of this water heater should b...

Страница 4: ...importance Before installing this water heater consult the installation section of these instructions After reading these installation and operating instructions select a location for the water heater where the floor is level and is easily accessible to a power supply and water connections It is recommended that the water heater be located near the center of greatest hot water usage to prevent hea...

Страница 5: ...NITY OF THE WATER HEATER This water heater must be located in an area where leakage of the tank or water line connections and the combination temperature and pressure relief valve will not result in damage to the area adjacent to the water heater or to lower floors of the structure When such locations cannot be avoided a suitable drain pan must be installed under the water heater The drain pan mus...

Страница 6: ...expansion DO NOT operate this water heater in a closed system without provisions for controlling thermal expansion Your water supplier or local plumbing inspector should be contacted on how to control this situation After installation of the water lines open the main water supply valve and fill the water heater While the water heater is filling open several hot water faucets to allow air to escape...

Страница 7: ...o the opening provided and marked for this purpose on the water heater Note Some models may already be equipped or supplied with a combination temperature and pressure relief valve Verify that the combination temperature and pressure relief valve complies with local codes If the combination temperature and pressure relief valve does not comply with local codes replace it with one that does Follow ...

Страница 8: ...water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system If hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow There should be no smoking or open flame near the faucet at the time it is open CAUTION INCREASING THE THERMOSTAT SETTING ABOVE THE PRES...

Страница 9: ...ng the thermostat on this water heater to obtain increased temperature water required by these appliances you may create the potential for scald injury To protect against injury you should install an ASSE approved mixing valve in the water system This valve will reduce point of discharge temperature by mixing cold and hot water in branch supply lines Such valves are available from the manufacturer...

Страница 10: ...he hot and cold water connections are identified on the top of the water heater Connect the hot and cold water lines to the installed nipples using unions Install a listed temperature pressure relief valve in the opening on the side of the water heater Figure 1 ...

Страница 11: ...on The 6 and 12 gallon models are equipped for installation with either top or side water connections They are shipped from the factory with side nipples installed and the alternate top connections plugged For ease of conversion the alternate top inlet is supplied with a dip tube If the top water connections are needed remove the installed side nipples and the pipe plugs from the alternate top con...

Страница 12: ...de panels and force the top panel upward This will separate the top panel from the water heater and allow further access to the water heater Check drain valve to make sure that it is closed Part the top fiberglass insulation to allow access to the plumbing and electrical connections Connect the cold water supply line and hot water outlet lines using elbows nipples and unions as shown in the diagra...

Страница 13: ...equire or allow other circuitry Consult your local power company to determine the correct electrical hook up in order to meet local utility and building codes and in order to obtain the most economical rates Also check to find out if you are required to obtain a permit before starting the installation The following chart shows the recommended fuse size for the maximum water heater wattage The maxi...

Страница 14: ...ater heater make sure you follow the steps below 1 Disconnect the power supply to the water heater Consult the plumbing professional or electric company in your area for service 2 Close the cold water supply shut off valve 3 Open the drain valve if provided on the water heater by inserting a standard flat head screwdriver into the slot and turning counter clockwise The drain valve has threads on t...

Страница 15: ...hat the plastic terminal shield has not been displaced replace the access panel The water heater is now ready for operation and the main switch can be closed Figure 4 CAUTION Before adjusting thermostat s turn off power supply to the water heater Hotter water increases the risk of scald injury Scalding may occur within five 5 seconds at a temperature setting of 140 F 60 C To protect against hot wa...

Страница 16: ...ls suggested below In some installations the maintenance interval may be more frequent depending on the amount of use and the operating conditions of the water heater Regular inspection and maintenance of the water heater will help to insure safe and reliable operation 1 Annually check the operation of the thermostat s 2 Bi annually check the seal around the heating elements for leaks If there is ...

Страница 17: ...ode rod hot water outlet nipple has been installed to extend tank life The anode rod should be inspected periodically every 2 years and replaced when necessary to prolong tank life Water conditions in your area will influence the time interval for inspection and replacement of the anode rod Contact the plumbing professional who installed the water heater or the manufacturer listed on the rating pl...

Страница 18: ...____________ Service Phone Days ______________________Nights ___________________________ Address _____________________________________________________ Supplier _____________________________________________________ Supplier Phone No _________________________________________________________ Manufactured under one or more of the following U S Patents RE 34 534 B1 5 341 770 4 416 222 4 628 184 4 669 4...

Страница 19: ...19 NOTES ...

Страница 20: ...20 NOTES ...

Отзывы: