Bradford White 238-37281-00R Скачать руководство пользователя страница 13

 

13

Gas Connections 

 

The gas supply lines must meet all requirements of the National Fuel Gas Code 
(ANSI Z223.1-Latest Edition), or in Canada CAN/CGA B149.1 Natural Gas 
Installation Code (Latest Edition) or CAN/CGA B149.2 Propane Installation 
Code (Latest Edition). 

 

The minimum permissible gas supply pressure for the purpose of input 
adjustment is one (1.0) inch 

(0.25 kPa) 

water column above the operating 

manifold pressure.  See the rating plate and gas valve for the manifold 
pressure and gas type.  The maximum permissible gas supply pressure is 
fourteen (14.0) inches 

(3.5 kPa)

 water column for natural gas and liquefied 

petroleum gases/propane gas. 

 

1.  Connect this water heater only to the type of gas (Natural or Propane gas) as 

shown on the rating plate.  Use clean black iron pipe or equivalent material 
approved by local codes and ordinances. (Dirt and scale from the pipe can 
enter the gas valve and cause it to malfunction).  The inlet gas line must have a 
minimum length of three (3) inches 

(7.6 cm)

 drip leg 

(sediment trap) 

installed as 

close to the water heater’s gas valve as possible.  A ground joint union must be 
installed as close to the water heater as possible in the gas supply line feeding 
the water heater to permit servicing of the water heater. Compounds used on 
the threaded joints of the gas piping must be resistant to the action of liquefied 
petroleum gases/propane gas.  DO NOT apply pipe dope to the gas valve inlet 
and make certain that no pipe dope has become lodged in the inlet screen of 
the gas valve.  Extreme care must be taken to ensure no pipe dope enters the 
gas valve.  Avoid excessive torque when tightening the gas supply line to the 
gas valve.  Excessive torque may result in cracking of the gas valve housing 
and could create a gas leak.  When tightening gas supply line to L.P. control, it 
is recommended to hold the inlet body of the control securely with an adequate 
wrench.  The suggested maximum torque is 31.5 ft. lbs. (4.4 kg-m).   

 

2.  This water heater and its gas connection must be leak tested before placing the 

water heater in operation.  Check for gas leaks with a soap and water solution 
and a brush or a commercial leak detector fluid. 

NEVER USE A MATCH OR 

OPEN FLAME FOR TESTING!

 

 

3.  While checking for leaks care must be taken to prevent solution from   

contacting the electrical connections at the control. If electrical connections at the 
control become wet, they must be thoroughly dried before attempting to operate the 
water heater. 

WARNING

 

The manufacturer of this water heater will not be liable for any damage or injury 

caused as a result of a cracked gas inlet as a result of excessive torque. 

CAUTION 

The water heater and individual shutoff valve must be disconnected from the gas 
supply piping system during any pressure testing of the system at test pressures in 
excess of 1/2 psi (3.5 kPa).  The water heater must be isolated from the gas supply 
piping system by closing its manual shutoff valve during any pressure testing of the 
gas supply system at test pressures equal to or less than 1/2 psi (3.5 kPa).  The 
supply line must be capped when not connected to the water heater. 

Содержание 238-37281-00R

Страница 1: ...nstalled and serviced by a plumbing professional MANUFACTURED HOME MOBILE HOME CLOSED COMBUSTION DIRECT VENTING INSTALLATION AND OPERATING INSTRUCTION MANUAL WARNING If the information in these instru...

Страница 2: ...e installation of this water heater We require that you carefully read this manual as well as the enclosed warranty and refer to it when questions arise If you have any specific questions concerning y...

Страница 3: ...arances 7 Combustion Air Supply 8 Venting 9 Water Connections 10 Gas Connections 13 Gas Conversion Instructions 14 GENERAL OPERATION 16 Lighting and Shutdown Instructions 17 Thermostat Adjustment 18 B...

Страница 4: ...ter includes the field installation of the following components roof jack air intake tube and heater tie down materials These components for field installation may have been shipped with this heater a...

Страница 5: ...s to eliminate any bacteria INSTALLATION Locating the Water Heater This water heater MUST NOT be installed in any location where gasoline or flammable vapors are likely to be present unless the instal...

Страница 6: ...MPT TO LIGHT ANY GAS APPLIANCE IF YOU ARE NOT CERTAIN OF THE FOLLOWING Liquefied petroleum gases propane gas and natural gas have an odorant added by the gas supplier that aids in detection of the gas...

Страница 7: ...ily cleanable way or b Installed with an optional leg kit that includes legs and or extensions that provide a minimum clearance of 6 beneath the water heater Note For California installation this wate...

Страница 8: ...to the heater AIR INTAKE INSTALLATION 3 7 6cm diameter telescoping air intake and leg enclosure are required to supply fresh air to the water heater for combustion kit P N 239 37025 01 for 30 gallon 1...

Страница 9: ...be fastened to the top of the water heater and to the adjacent walls with the screws provided See Figure 2 Venting Make certain the flue baffle is in place and centered in flue tube Cut a 7 1 4 inch...

Страница 10: ...let and hot water outlet are dielectric waterway fittings with 3 4 NPT male thread Make the proper plumbing connections between the water heater and the plumbing system to the house Install a shut off...

Страница 11: ...Relief Valves The combination temperature and pressure relief valve shall be marked with a maximum set pressure not to exceed the maximum working pressure of the water heater The combination temperat...

Страница 12: ...cold and hot water in branch supply lines Such valves are available from the manufacturer of this water heater or a local plumbing supplier Please consult with a plumbing professional WARNING Hydroge...

Страница 13: ...dope has become lodged in the inlet screen of the gas valve Extreme care must be taken to ensure no pipe dope enters the gas valve Avoid excessive torque when tightening the gas supply line to the gas...

Страница 14: ...or by removing cap from gas regulator Depress and rotate knob clockwise to NAT setting using a screwdriver Replace cap Figure 3 3 Change the pilot regulator by removing pilot regulator cap Depress and...

Страница 15: ...lly provided with the water heater 2 Change the main gas regulator to LP as noted in step 2 of the instructions 3 Change the pilot regulator to LP as noted in step 3 of the instructions 4 Replace equi...

Страница 16: ...hed to the water heater 3 Replace equipped for tag with tag supplied in cloth bag for gas being used Gas knob shown in OFF position GENERAL OPERATION TO FILL THE WATER HEATER 1 Close the water heater...

Страница 17: ...b clockwise to the OFF position 3 Shut off the gas supply to the water heater 4 Close the cold water supply shut off valve 5 Open the drain valve on the water heater by turning the knob counter clockw...

Страница 18: ...ial until the minimum acceptable temperature is achieved See figure 5 above for approximate temperature settings Figure 6 The thermostat dial is set to its lowest temperature setting when shipped from...

Страница 19: ...ds at a temperature setting of 140 F 60 C To protect against hot water injury install an ASSE approved mixing valve in the water system This valve will reduce point of discharge temperature by mixing...

Страница 20: ...valve has not become encrusted with lime Lift the lever at the lever at the top of the valve several times until the valve seats properly without leaking and operates freely 7 Monthly drain off a gall...

Страница 21: ...TH OF TIME THAT PARTS AND THE WATER HEATER ARE WARRANTED Complete the following information and retain for future reference Model No Serial No Service Phone Days Nights Address Supplier Supplier Phone...

Страница 22: ...22 TYPICAL INSTALLATION...

Страница 23: ...berglass Insulation 14 Pilot Assembly 4 Glass Lined Tank 15 Gas Feed Line Burner 5 Tank Skirt Assembly 16 Main Burner Orifice 6 Jacket Base Assembly 17 Burner 7 Flue Baffle Assembly 18 Pilot Orifice N...

Страница 24: ...OTE part description part number model and serial number and gas type must be specified when ordering service parts ITEM NO PART DESCRIPTION 14 Pilot Assembly 15 Gas Feedline Main Burner 16 Orifice Ma...