Bradford White 238-37281-00R Скачать руководство пользователя страница 11

 

11

Water connections continued- 

 

If this water heater is installed in a closed water supply system, such as the one 
having a back-flow preventer in the cold water supply, provisions shall be made 
to control thermal expansion.  

DO NOT

 operate this water heater in a closed 

system without provisions for controlling thermal expansion.  Your water 
supplier or local plumbing inspector should be contacted on how to control this 
situation. 

 

After installation of the water lines, open the main water supply valve and fill the 
water heater.  While the water heater is filling, open several hot water faucets 
to allow air to escape from the water system.  When a steady stream of water 
flows through the faucets, close them and check all water connections for 
possible leaks.

  NEVER OPERATE THE WATER HEATER WITHOUT FIRST 

BEING CERTAIN IT IS FILLED WITH WATER.

 

WARNING 

For protection against excessive temperatures and pressure, install temperature and 
pressure protective equipment required by local codes, but not less than a 
combination temperature and pressure relief valve certified by a nationally 
recognized testing laboratory that maintains periodic inspection of production of 
listed equipment or materials as meeting the requirements of the Standard for 

Relief 

Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI 
Z21.22 or the Standard CAN1-4.4. Temperature and Pressure

 and the Standard 

CAN1-4.4, Temperature, Pressure, Temperature and Pressure Relief Valves and 
Vacuum Relief Valves

.  The combination temperature and pressure relief valve shall 

be marked with a maximum set pressure not to exceed the maximum working 
pressure of the water heater.  The combination temperature and pressure relief 
valve shall also have an hourly rated temperature steam BTU discharge capacity not 
less than the hourly rating of the water heater. 

 

Install the combination temperature and pressure relief valve into the opening 
provided and marked for this purpose on the water heater. 

 

Note:  Some models may already be equipped or supplied with a combination 
temperature and pressure relief valve.  Verify that the combination temperature and 
pressure relief valve complies with local codes.  If the combination temperature and 
pressure relief valve does not comply with local codes, replace it with one that does.  
Follow the installation instructions above on this page. 

 

Install a discharge line so that water discharged from the combination temperature 
and pressure relief valve will exit within six (6) inches 

(15.2 cm)

 above, or any 

distance below the structural floor and cannot contact any live electrical part. The 
discharge line is to be installed to allow for complete drainage of both the 
combination temperature and pressure relief valve and the discharge line.  The 
discharge opening must not be subjected to blockage or freezing.

  DO NOT

 thread, 

plug or cap the discharge line.  It is recommended that a minimum clearance of four 
(4) inches 

(10.2 cm)

 be provided on the side of the water heater for servicing and 

maintenance of the combination temperature and pressure relief valve. 

 

Do not place a valve between the combination temperature and pressure relief valve 
and the tank.

 

Содержание 238-37281-00R

Страница 1: ...nstalled and serviced by a plumbing professional MANUFACTURED HOME MOBILE HOME CLOSED COMBUSTION DIRECT VENTING INSTALLATION AND OPERATING INSTRUCTION MANUAL WARNING If the information in these instru...

Страница 2: ...e installation of this water heater We require that you carefully read this manual as well as the enclosed warranty and refer to it when questions arise If you have any specific questions concerning y...

Страница 3: ...arances 7 Combustion Air Supply 8 Venting 9 Water Connections 10 Gas Connections 13 Gas Conversion Instructions 14 GENERAL OPERATION 16 Lighting and Shutdown Instructions 17 Thermostat Adjustment 18 B...

Страница 4: ...ter includes the field installation of the following components roof jack air intake tube and heater tie down materials These components for field installation may have been shipped with this heater a...

Страница 5: ...s to eliminate any bacteria INSTALLATION Locating the Water Heater This water heater MUST NOT be installed in any location where gasoline or flammable vapors are likely to be present unless the instal...

Страница 6: ...MPT TO LIGHT ANY GAS APPLIANCE IF YOU ARE NOT CERTAIN OF THE FOLLOWING Liquefied petroleum gases propane gas and natural gas have an odorant added by the gas supplier that aids in detection of the gas...

Страница 7: ...ily cleanable way or b Installed with an optional leg kit that includes legs and or extensions that provide a minimum clearance of 6 beneath the water heater Note For California installation this wate...

Страница 8: ...to the heater AIR INTAKE INSTALLATION 3 7 6cm diameter telescoping air intake and leg enclosure are required to supply fresh air to the water heater for combustion kit P N 239 37025 01 for 30 gallon 1...

Страница 9: ...be fastened to the top of the water heater and to the adjacent walls with the screws provided See Figure 2 Venting Make certain the flue baffle is in place and centered in flue tube Cut a 7 1 4 inch...

Страница 10: ...let and hot water outlet are dielectric waterway fittings with 3 4 NPT male thread Make the proper plumbing connections between the water heater and the plumbing system to the house Install a shut off...

Страница 11: ...Relief Valves The combination temperature and pressure relief valve shall be marked with a maximum set pressure not to exceed the maximum working pressure of the water heater The combination temperat...

Страница 12: ...cold and hot water in branch supply lines Such valves are available from the manufacturer of this water heater or a local plumbing supplier Please consult with a plumbing professional WARNING Hydroge...

Страница 13: ...dope has become lodged in the inlet screen of the gas valve Extreme care must be taken to ensure no pipe dope enters the gas valve Avoid excessive torque when tightening the gas supply line to the gas...

Страница 14: ...or by removing cap from gas regulator Depress and rotate knob clockwise to NAT setting using a screwdriver Replace cap Figure 3 3 Change the pilot regulator by removing pilot regulator cap Depress and...

Страница 15: ...lly provided with the water heater 2 Change the main gas regulator to LP as noted in step 2 of the instructions 3 Change the pilot regulator to LP as noted in step 3 of the instructions 4 Replace equi...

Страница 16: ...hed to the water heater 3 Replace equipped for tag with tag supplied in cloth bag for gas being used Gas knob shown in OFF position GENERAL OPERATION TO FILL THE WATER HEATER 1 Close the water heater...

Страница 17: ...b clockwise to the OFF position 3 Shut off the gas supply to the water heater 4 Close the cold water supply shut off valve 5 Open the drain valve on the water heater by turning the knob counter clockw...

Страница 18: ...ial until the minimum acceptable temperature is achieved See figure 5 above for approximate temperature settings Figure 6 The thermostat dial is set to its lowest temperature setting when shipped from...

Страница 19: ...ds at a temperature setting of 140 F 60 C To protect against hot water injury install an ASSE approved mixing valve in the water system This valve will reduce point of discharge temperature by mixing...

Страница 20: ...valve has not become encrusted with lime Lift the lever at the lever at the top of the valve several times until the valve seats properly without leaking and operates freely 7 Monthly drain off a gall...

Страница 21: ...TH OF TIME THAT PARTS AND THE WATER HEATER ARE WARRANTED Complete the following information and retain for future reference Model No Serial No Service Phone Days Nights Address Supplier Supplier Phone...

Страница 22: ...22 TYPICAL INSTALLATION...

Страница 23: ...berglass Insulation 14 Pilot Assembly 4 Glass Lined Tank 15 Gas Feed Line Burner 5 Tank Skirt Assembly 16 Main Burner Orifice 6 Jacket Base Assembly 17 Burner 7 Flue Baffle Assembly 18 Pilot Orifice N...

Страница 24: ...OTE part description part number model and serial number and gas type must be specified when ordering service parts ITEM NO PART DESCRIPTION 14 Pilot Assembly 15 Gas Feedline Main Burner 16 Orifice Ma...

Отзывы: