Standards and certifications • International certifications

Automation PC 820 User's Manual V 1.00

9. International certifications

B&R products and services comply with applicable standards. They are international standards
from organizations such as ISO, IEC and CENELEC, as well as national standards from
organizations such as UL, CSA, FCC, VDE, ÖVE, etc. We give special consideration to the
reliability of our products in an industrial environment.

Certifications

USA and Canada 

All important B&R products are tested and listed by Underwriters Laboratories and 
checked quarterly by a UL inspector.
This mark is valid for the USA and Canada and simplifies certification of your machines 
and systems in these areas.

Europe

All harmonized EN standards for the applicable guidelines are met.

Table 159: International certifications

Содержание Automation PC 820

Страница 1: ...er Rainer Industrie Elektronik Ges m b H makes no warranty expressed or implied with regards to the products or the documentation contained within this book In addition Bernecker Rainer Industrie Elek...

Страница 2: ...2 Automation PC 820 User s Manual V 1 00...

Страница 3: ...3 Automation PC 820 User s Manual V 1 00 Chapter 1 General information Chapter 2 Technical data Chapter 3 Commissioning Chapter 4 Software Chapter 5 Standards and certifications Chapter 6 Accessories...

Страница 4: ...4 Automation PC 820 User s Manual V 1 00...

Страница 5: ...5 Automation PC 820 User s Manual V 1 00 Chapter 7 Maintenance Servicing Appendix A Figure index Table index Model number index Index...

Страница 6: ...6 Automation PC 820 User s Manual V 1 00...

Страница 7: ...fety notices 18 4 Guidelines 18 5 Model numbers 19 5 1 System units 19 5 2 CPU boards 945GME 19 5 3 Power supply with heat sink 19 5 4 Main memory 20 5 5 Plug in cards 20 5 6 Replacement fan kit 20 5...

Страница 8: ...6 15 Battery 61 2 6 16 Hardware Security Key dongle 62 2 6 17 CompactFlash slot 1 63 2 6 18 CompactFlash slot 2 64 3 Individual components 65 3 1 CPU boards 945GME 65 3 1 1 Technical data 65 3 2 Main...

Страница 9: ...1 5 14 Baseboard panel features 123 1 6 Boot 128 1 7 Security 130 1 7 1 Hard disk security user password 131 1 7 2 Hard disk security master password 132 1 8 Power 133 1 9 Exit 135 1 10 BIOS default s...

Страница 10: ...evice Interface ADI Control Center 170 6 1 Functions 170 6 2 Installation 172 6 3 SDL equalizer setting 172 Chapter 5 Standards and certifications 173 1 Applicable European guidelines 173 2 Overview o...

Страница 11: ...8 Other tests 193 8 1 Protection 193 9 International certifications 194 Chapter 6 Accessories 195 1 Overview 195 2 CAN plugs 4 pin 196 2 1 General information 196 2 2 Order data 196 2 3 Technical data...

Страница 12: ...Temperature humidity diagram Operation and storage 210 7 4 Creating a bootable USB flash drive 211 7 4 1 5 4 1 Requirements 211 7 4 2 Procedure 211 Chapter 7 Maintenance Servicing 213 1 Changing the b...

Страница 13: ...on page 38 added According updates regarding small changes made to interfaces and component positions for the APC820 L2 cache of CPU board 5PC800 B945 00 corrected to 2 MB Section 5 5 Plug in cards o...

Страница 14: ...l of weapons systems 2 2 Protection against electrostatic discharges Electrical components that are vulnerable to electrostatic discharge ESD must be handled accordingly 2 2 1 Packaging Electrical com...

Страница 15: ...e logic controllers and when using operating and monitoring devices as control systems in conjunction with a soft PLC e g B R Automation Runtime or comparable products or a slot PLC e g B R LS251 or c...

Страница 16: ...PE rail The ground connection must be established when testing the operating and monitoring devices or the uninterruptible power supply even when operating them for only a short time Before turning t...

Страница 17: ...sources 2 7 Environmentally friendly disposal All B R programmable controllers operating and monitoring devices and uninterruptible power supplies are designed to inflict as little harm on the environ...

Страница 18: ...e g dimension diagrams etc Safety notice Description Danger Disregarding the safety regulations and guidelines can be life threatening Caution Disregarding the safety regulations and guidelines can r...

Страница 19: ...Duo L7400 1 5 GHz 667 MHz FSB 4 MB L2 cache 945GME chipset 2 sockets for SO DIMM DDR2 modules Page 65 5PC800 B945 02 CPU board Intel Core 2 Duo U7500 1 06 GHz 533 MHz FSB 2 MB L2 cache 945GME chipset...

Страница 20: ...rt description Note 8BXF001 0000 00 ACPmulti fan module Replacement filter for 5PC820 SX01 00 system unit Page 68 Table 9 Model numbers Fan kits Model number Short description Note 0AC201 91 Lithium b...

Страница 21: ...IDE ATA interface Page 204 5CFCRD 8192 03 CompactFlash 8192 MB SSI CompactFlash card with 8192 MB SLC NAND flash and IDE ATA interface Page 204 5MMUSB 2048 00 USB flash drive 2 GB SanDisk USB 2 0 fla...

Страница 22: ...ional with SP 2c ENG Microsoft OEM Windows XP Professional Service Pack 2c CD English Only available with a new device A CompactFlash card is required for operation This is not included in delivery an...

Страница 23: ...rs that make the ACOPOSmulti so easy to use The Automation PC 820 was developed for the ACOPOSmulti system and is equipped on the machine for rough environmental conditions Because the APC820 can be c...

Страница 24: ...e Monitor Panel video output supports SDL DVI and monitor signals Fans BIOS AMI 24 VDC supply voltage via ACOPOSmulti supply bus bar Installation as with ACOPOSmulti system units Dongle Battery 1 2 Sy...

Страница 25: ...ic system 5MMDDR 0512 01 512 MB 5MMDDR 1024 01 1 GB 5MMDDR 2048 01 2 GB 5AC802 HS00 00 CPU board Main memory Power supply with heat sink Main memory A system unit consists of a housing and main board...

Страница 26: ...SWWXP 0500 MUL XP Pro SP2c Multi language 5SWWXP 0428 ENG XPe FP2007 APC820 B945GME German 5PC820 SX01 00 System unit A system unit consists of a housing and main board Configuration Software accessor...

Страница 27: ...riations 2 1 1 Interfaces Figure 3 5PC820 SX01 00 interface overview Front side A0 Power LED Node switch POWERLINK Node switch CAN CompactFlash LED Link LED Run LED CAN LED POWERLINK LED Ethernet ETH1...

Страница 28: ...s Manual V 1 00 Figure 4 5PC820 SX01 00 interface overview Front side A1 Supply voltage via ACOPOSmulti mounting plate Battery Dongle Fan CompactFlash slot 2 CompactFlash slot 1 USB5 max 1A Reset but...

Страница 29: ...20 User s Manual V 1 00 Figure 5 5PC820 SX01 00 LED description Front side A1 CAN PWR RUN CF LNK ACT ACT LNK SDL IF EPL APC820 x1 X16 x1 x16 EPL CAN LNK IF Node switch POWERLINK Node switch CAN Power...

Страница 30: ...ce overview Top side A0 USB2 USB4 max 500 mA USB1 USB3 max 1 A POWERLINK ETH1 Ethernet 10 100 1000 ETH2 Ethernet 10 100 1000 COM2 RS232 422 485 COM1 RS232 CAN interface Monitor Panel SDL Smart Display...

Страница 31: ...e 7 5PC820 SX01 00 interface overview Top side A1 POWERLINK ETH2 Ethernet 10 100 1000 ETH1 Ethernet 10 100 1000 COM2 RS232 422 485 COM1 RS232 Monitor Panel SDL Smart Display Link DVI CAN LED PCIec Car...

Страница 32: ...3 GB Graphics Controller Intel Graphics Media Accelerator 950 see page 65 Power failure logic Controller Buffer time MTCX1 10 ms Real time clock RTC Battery buffered Accuracy Yes At 25 C typ 12 ppm 1...

Страница 33: ...or 300 s Component dependent see section 2 4 2 Power calculation with 5PC820 SX01 00 Mechanical characteristics Housing4 Material Front cover Cable cover Steel Niro plastic Polycarbonate black Polycar...

Страница 34: ...ient temperature typ 58 ppm 5 seconds worst case 220 ppm 19 seconds 3 The lifespan of 2 years is only valid if an SRAM module is being used Without SRAM module a lifespan of 1 years can be expected 4...

Страница 35: ...ure 8 Dimensions 5PC820 SX01 00 344 25 13 236 257 5 2 37 65 19 5 5 6 5 82 5 8 50 5 10 0 1 mm 0 2 mm 0 3 mm 0 5 mm 0 8 mm All dimensions in mm 37 13 4 53 42 205 195 197 General tolerance acc to DIN ISO...

Страница 36: ...45 03 Main memory 5MMDDR 0512 01 5MMDDR 1024 01 5MMDDR 2048 01 System unit 5PC820 SX01 00 Maximum ambient temperature U7500 CM 423 5PC800 B945 00 L2400 5PC800 B945 01 L7400 Add Plug in cards PCIec car...

Страница 37: ...be downloaded for free from the download area on the B R homepage www br automation com Figure 10 Temperature sensor position Position Measurement point for Measurement Max specified 1 CPU Processor t...

Страница 38: ...the fan is controlled The RPM depends on the temperature measured The fans are only switched off again when the evaluated temperature remains 6 C below the start up temperature for a time span of 30...

Страница 39: ...d specifications correspond to the humidity at an ambient temperature of 30 C More detailed information about the specific temperature dependent humidity values can be found in the technical data of t...

Страница 40: ...a DC DC converter These electrically isolated 15 V feed further DC DC converters which generate the remaining voltages After the system is turned on e g using the power button the voltages 3V3 and 5 V...

Страница 41: ...ax 5W USB1 USB3 USB5 PCIec card power max 4W Baseboard fixed device CompactFlash each 1W 2 slot PCIec card power max 4W 26 30 18 14 43 CM423 T7400 L2400 L7400 U7500 Devices 3V3 Devices 12V This system...

Страница 42: ...outside Interface optional or internal Gbit LAN transformer Gbit LAN transformer SDVO B TMDS Sil 1362A System fan with Tacho Terminating resistor CompactFlash internal Supply voltage DC DC controller...

Страница 43: ...fuse replacement necessary The device must be returned to B R for repairs if the fuse is blown because of an error 2 6 2 Ground If the APC820 is secured it is automatically connected to ground ACOPOS...

Страница 44: ...does ensure the performance of all USB devices that they provide Important Because of general PC specifications this interface should be handled with extreme care with regard to EMC location of cable...

Страница 45: ...nt side at the bottom of the APC820 Universal Serial Bus USB5 Transfer rate Low speed 1 5 MBit s full speed 12 MBit s to high speed 480 Mbit s Power Supplies1 USB5 1 For safety every USB port is equip...

Страница 46: ...trically isolated 9 pin DSUB male UART 16550 compatible 16 byte FIFO Transfer rate Max 115 kBaud Cable length Max 15 m Pin Assignment 1 DCD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI Table 19 Pin...

Страница 47: ...al V 1 00 Grounding line Cable cross section Wire insulation Conductor resistance 1 x 0 34 mm 22AWG 19 tinned Cu wire PE 59 km Outer sheathing Material Characteristics Entire shielding PUR mixture Hal...

Страница 48: ...Serial interfaces COM2 RS232 RS422 485 9 pin DSUB connector Type RS232 not modem compatible electrically isolated UART 16550 compatible 16 byte FIFO Transfer rate Max 115 kBit s Bus length Max 15 m M...

Страница 49: ...PE 82 km Wires stranded in pairs Paired shield with aluminum foil Grounding line Cable cross section Wire insulation Conductor resistance 1 x 0 34 mm 22AWG 19 tinned Cu wire PE 59 km Outer sheathing...

Страница 50: ...lengths or larger transfer rates be closed Normally a passive terminator can be used on the bus ends by connecting each of the signal lines with 120 resistance RS485 Bus length and cable type The maxi...

Страница 51: ...V 1 00 Grounding line Cable cross section Wire insulation Conductor resistance 1 x 0 34 mm 22AWG 19 tinned Cu wire PE 59 km Outer sheathing Material Characteristics Entire shielding PUR mixture Halog...

Страница 52: ...Transfer rate Max 500 kBit s Bus length Max 1000 m Pin CAN bus 1 CAN_H CAN High 2 CAN CAN Ground 3 CAN_L CAN Low 4 SHLD shield Table 30 CAN CAN node switch x1 x16 Both of these hex switches x1 x16 are...

Страница 53: ...located on the top side see image 7 5PC820 SX01 00 interface overview Top side A1 on page 31 LED On Off Yellow The terminating resistor integrated in the bus controller is turned on The terminating re...

Страница 54: ...into the BASIC_ETHERNET status flickering Controlled Node CN The bus is monitored for POWERLINK frames If a frame is not received within the configured time window timeout the interface goes directly...

Страница 55: ...The PDO data sent corresponds to the PDO mapping used However cyclic data is not yet evaluated On OPERATIONAL The interface status is OPERATIONAL Blinking approx 2 5 Hz STOPPED The interface status is...

Страница 56: ...STP Cat5e Transfer rate 10 100 1000 MBit s1 1 Change over takes place automatically Cable length max 100 m min Cat5e Speed LED On Off Green 100 MBit s 10 MBit s2 2 The 10 MBit s transfer speed connec...

Страница 57: ...ling S STP Cat5e Transfer rate 10 100 1000 MBit s1 1 Change over takes place automatically Cable length max 100 m min Cat5e Speed LED On Off Green 100 MBit s 10 MBit s2 2 The 10 MBit s transfer speed...

Страница 58: ...ng Power Green On Supply voltage OK Red On Thesystemisinstandbymode S5 soft off mode or S4 hibernate mode Suspend to Disk CF Yellow On Indicates access toCompactFlash read or write Link SDL Yellow On...

Страница 59: ...ue profiles can be defined using the 16 position CMOS profile switch Switch position Description 0 Profile 0 Default profile reserved 1 Profile 1 Optimized for system units 5PC810 SX01 00 and 5PC810 S...

Страница 60: ...PC with ATX power supply press and release Switches on APC820 or shuts down operating system and switches off the APC820 press and hold ATX power supply switches off without shutting down the APC820 d...

Страница 61: ...load 1 second during the measurement and then evaluated The evaluated battery status is displayed in the BIOS Setup pages under Advanced Baseboard monitor and in the B R Control Center ADI driver but...

Страница 62: ...on the DS1425 from MAXIM previously Dallas Semiconductors for software copy protection The hardware security key is located behind the cable cover Hardware security key A hardware security key dongle...

Страница 63: ...Flash card 5CFCRD 1024 04 1024 MB B R CompactFlash card 5CFCRD 2048 04 2048 MB B R CompactFlash card 5CFCRD 4096 04 4096 MB B R CompactFlash card 5CFCRD 8192 04 8192 MB B R CompactFlash card 5CFCRD 00...

Страница 64: ...FCRD 1024 04 1024 MB B R CompactFlash card 5CFCRD 2048 04 2048 MB B R CompactFlash card 5CFCRD 4096 04 4096 MB B R CompactFlash card 5CFCRD 8192 04 8192 MB B R CompactFlash card 5CFCRD 0064 03 Compact...

Страница 65: ...U7500 1 06 GHz 65 nm 32 KB 2 MB 533 MHz Intel Celeron M 423 1 06 GHz 65 nm 32 KB 1 MB 533 MHz Intel Core 2 Duo T7400 2 16 GHz 65 nm 32 KB 4 MB 667 MHz Chipset Intel 945GME Intel 82801 GMH ICH7M DH DR...

Страница 66: ...d when two modules of different sizes e g 1 GB and 2 GB are plugged in When two 2 GB modules are plugged in only 3 GB of main memory can be used 3 2 1 Technical data Figure 16 Main memory Features 5MM...

Страница 67: ...upply with heat sink General information 5AC802 HS00 00 5AC802 HS00 01 Suited for CPU board 5PC800 B945 00 5PC800 B945 01 5PC800 B945 02 5PC800 B945 03 5PC800 B945 04 Mechanical characteristics Materi...

Страница 68: ...s subject to wear and must be checked with appropriate frequency and cleaned or replaced when not functioning properly e g due to dirt and grime Figure 18 Replacement fan 8BXF001 0000 00 Features 8BXF...

Страница 69: ...at monitors the card s temperature This value is read out in the BIOS menu item Advanced Baseboard Panel Features Baseboard Monitor on page 125 and in the ADI Figure 19 Dimensions PCIec cards Informat...

Страница 70: ...Figure 20 Ethernet card 10 100 1000 5ACPCC ETH0 00 Information The following characteristics features and limit values only apply to this individual component and can deviate from those specified for...

Страница 71: ...rate 10 100 1000 MBit s1 1 Change over takes place automatically Cable length max 100 m min Cat5e Speed LED On Off Green 100 MBit s 10 MBit s2 2 The 10 MBit s transfer speed connection is only presen...

Страница 72: ...ified for the entire device For the entire device in which this individual component is used refer to the data given specifically for the entire device POWERLINK card 2 connections Cabling S STP Cat5e...

Страница 73: ...is status the interface goes into the PRE_OPERATIONAL_1 state single flash Single flash approx 1 Hz PRE_OPERATIONAL_1 The interface status is PRE_OPERATIONAL_1 Managing Node MN The MN starts the opera...

Страница 74: ...umber x1 x16 Both of these hex switches x16 x1 are used to configure the station number for the POWERLINK Station numbers are permitted between 00 and FD Switch position x1 x16 Description 0 0 Operati...

Страница 75: ...nting information The APC820 must be secured to the first position of the ACOPOSmulti mounting plate The environmental conditions must be taken into consideration The APC820 is only permitted for oper...

Страница 76: ...ing plate and also be non flammable level and free of contaminants The cutout for the feed through heat sink and the mounting holes type and amount are to be prepared according to the dimension diagra...

Страница 77: ...mounting surface for the mounting plate must provide sufficient stability for the mounting plate and also be non flammable level and free of contaminants Connection of supply and return lines The pos...

Страница 78: ...el range of the front cover Keep the swivel range of the front cover on the front side of the APC820 free when installed to prevent problems connecting peripheral devices to the APC820 Figure 24 Swive...

Страница 79: ...g the mounting clip s on the top Clip the APC820 into the backplane module The APC820 must be thoroughly attached so that it rests straight in the backplane module in order for the module contacts to...

Страница 80: ...80 Commissioning Installation Automation PC 820 User s Manual V 1 00 Figure 26 Tightening the fastening screws...

Страница 81: ...talling cables it is not permitted to have a flex radius smaller than the minimum value specified Figure 27 Flex radius Cable connection Information The specified flex radius can be found in the Autom...

Страница 82: ...system startup This is caused by varying startup speeds CompactFlash cards with older technology require significantly more time during system startup than CompactFlash cards with newer technology Thi...

Страница 83: ...ransferred to the CMOS If the data is not OK then the CMOS data is checked for validity An error message is output if the CMOS data contains errors and the boot procedure can be continued by pressing...

Страница 84: ...can boot from the network Table 58 945GME bios relevant keys at POST AMIBIOS C 2005 American Megatrends Inc APC2R114 Bernecker Rainer Industrie Elektronik H1 14 Serial Number 133453 CPU Intel R Core...

Страница 85: ...to the previous item Cursor Go to the next item Changes the setting of the selected function Enter Changes to the selected menu PgUp Change to the previous page PgDn Change to the previous page Pos 1...

Страница 86: ...or type None CPU frequency Displays the processor frequency None System memory Displays the system memory size None Product revision Displays the CPU board HW revision None Serial number Displays the...

Страница 87: ...ngs Enter Opens submenu see Graphics configuration on page 97 CPU configuration Configures CPU settings Enter Opens submenu see CPU configuration on page 101 Chipset configuration Configures the chips...

Страница 88: ...on page 116 Keyboard mouse configuration Configuration of the keyboard mouse options Enter Opens submenu see Keyboard mouse configuration on page 118 Remote access configuration Configures the remote...

Страница 89: ...Suspend mode Selects the ACPI status to be used when Suspend Mode is enabled S1 POS Sets S1 as Suspend Mode Only a few functions are disabled and are available again at the touch of a button S3 STR Se...

Страница 90: ...ith this function a temperature can be set at which the CPU automatically reduces its speed Disabled Disables this function 50 C 60 C 70 C 80 C 90 C Temperature setting for the passive cooling trip po...

Страница 91: ...gement bus controller is assigned a PCI interrupt Yes Automatic assignment of a PCI interrupt No No assignment of an interrupt Allocate IRQ to PCIEX2 Use this function to set whether or not the PCIEX2...

Страница 92: ...Table 63 945GME Advanced PCI IRQ Resource Exclusion setting options BIOS setting Meaning Setting options Effect Table 62 945GME Advanced PCI configuration setting options cont Advanced PCI IRQ Resour...

Страница 93: ...INTD PATA UHCI3 Option for setting the PIRQ E Auto Automatic assignment by the BIOS and operating system 5 6 7 9 10 12 Manual assignment Table 64 945GME Advanced PCI Interrupt Routing setting options...

Страница 94: ...exclusively no IRQ sharing Information Is only displayed if a PIRQ is manually set e g 5 None No interrupt is assigned x Assigns the PIRQ as 1st exclusive PCI IRQ 2nd Exclusive PCI With this option y...

Страница 95: ...eactivates the PCI Express connection function Information If you are not using any PCI Express devices this option should be deactivated Auto Automatic assignment by the BIOS and operating system Ena...

Страница 96: ...function Information If you are not using any PCI Express devices this option should be deactivated Auto Automatic assignment by the BIOS and operating system Enabled Enables this function Disabled D...

Страница 97: ...le Interrupt Controller on PCIE port 3 When APIC mode is activated additional IRQ resources are made available to the system Disabled Disables this function Enabled Enables this function Figure 36 945...

Страница 98: ...necessary DVMT FIXED Memory Option for setting the amount of memory used for the DVMT mode 64MB 64MB of main memory can be used 128MB 128MB of main memory can be used Maximum DVMT The remaining avail...

Страница 99: ...Centering The screen content is output centered on the display Expand Text The text is stretched across the entire surface of the display Expand Graphics The graphics are stretched across the entire...

Страница 100: ...means that when a DVI monitor is connected while the operating system is running it is detected automatically and activated Configuration mode persistence means that for example a dual DVI configurat...

Страница 101: ...ables this function Disabled Disables this function Core Multi Processing When using a Dual Core processor this option can be used to disable a core Enabled Both cores are used in a Dual Core processo...

Страница 102: ...d if the value Automatic or Maximum Speed is set for the option Intel R SpeedStep TM tech Information This option is not available for Celeron M processors xxxx MHz The processor speed is limited to t...

Страница 103: ...mit value for the limitation DT in SPD Option to determine whether the GMCH Graphics and Memory Controller Hub supports DT Delta Temperature in the SPD Serial Presence Detect Management Algorithm of t...

Страница 104: ...esources available to the system are expanded when the APIC mode is enabled APIC ACPI SCI IRQ This option is used to modify the SCI IRQ when in APIC Advanced Programmable Interrupt Controller mode Dis...

Страница 105: ...e 40 945GME Advanced Clock Configuration BIOS setting Meaning Setting options Effect Spread spectrum With this option the cycle frequency can be modulated by reducing electromagnetic disturbances Enab...

Страница 106: ...ured here Enter Opens submenu See Primary IDE master on page 108 Primary IDE slave The drive in the system that is connected to the IDE primary slave port is configured here Enter Opens submenu See Pr...

Страница 107: ...IDE Detect Time Out Sec Configuring thetime overrunlimitvalue for the ATA ATAPI device identification 0 5 10 15 20 25 30 35 Time setting in seconds ATA PI 80PinCable Detection Detects whether an 80 pi...

Страница 108: ...rted by the system Block multi sector transfer This option enables the block mode for IDE hard drives When this option is enabled the numberof blocks per request from the configuration sector of the h...

Страница 109: ...in the Windows device manager in order to guarantee maximum performance Only possible when manually setting up the drive Auto Automatic definition of the transfer rate Disabled Manual definition of th...

Страница 110: ...rted by the system Block multi sector transfer This option enables the block mode for IDE hard drives When this option is enabled the numberof blocks per request from the configuration sector of the h...

Страница 111: ...in the Windows device manager in order to guarantee maximum performance Only possible when manually setting up the drive Auto Automatic definition of the transfer rate Disabled Manual definition of th...

Страница 112: ...rted by the system Block multi sector transfer This option enables the block mode for IDE hard drives When this option is enabled the numberof blocks per request from the configuration sector of the h...

Страница 113: ...n the Windows device manager in order to guarantee maximum performance Only possible when manually setting up the drive Auto Automatic definition of the transfer rate Disabled Manual definition of the...

Страница 114: ...rted by the system Block multi sector transfer This option enables the block mode for IDE hard drives When this option is enabled the numberof blocks per request from the configuration sector of the h...

Страница 115: ...n the Windows device manager in order to guarantee maximum performance Only possible when manually setting up the drive Auto Automatic definition of the transfer rate Disabled Manual definition of the...

Страница 116: ...supported again after the operating system has started A USB keyboard is still recognized during the POST Disabled Disables this function Enabled Enables this function Auto Automatic enabling Table 76...

Страница 117: ...NT USB 2 0 controller mode Settings can be made for the USB controller Full speed 12 MBps Hi speed 480 MBps BIOS EHCI hand off The support for the operating system can be set up without the fully auto...

Страница 118: ...or functions of the numerical keypad are enabled On Numeric keypad is enabled Typematic rate The key repeat function is set here Slow Slow key repeat Fast Fast key repeat Table 77 945GME Advanced Keyb...

Страница 119: ...erface COM 3 Enables the COM3 interface as remote access interface Base address IRQ Serial connection display for the logical address and interrupt as long as disabled is not entered in the remote acc...

Страница 120: ...on can be chosen here as long as disabled is not entered in the remote access field ANSI VT100 VT UTF8 Manual configuration of the connection type VT UTF8 Combo Key Support With this option the VT UTF...

Страница 121: ...e Board temperature Displays the board temperature in degrees Celsius and Fahrenheit None CPU temperature Displays the processor s temperature in degrees Celsius and Fahrenheit None Top DIMM Environme...

Страница 122: ...processor fan None VcoreA Displays the processor s core voltage A in volts None 3 3VSB Displays the current voltage of the 3 3 volt supply None 5VSB Displays the current voltage of the 5 volt supply...

Страница 123: ...e MTCX FPGA Displays the MTCX FPGA firmware version None CMOS profile Shows the CMOS profile number None Device ID Displays the hexadecimal value of the hardware device ID None Compatibility ID Displa...

Страница 124: ...rightness For setting the brightness of the selected panel 0 10 20 30 40 50 60 70 80 90 100 For setting the brightness in of the selected panel Changes take effect after saving and restarting the syst...

Страница 125: ...ys the temperature in the upper part of the baseboard in degrees Celsius and Fahrenheit None Baseboard Center Displays the temperature in the center of the baseboard in degrees Celsius and Fahrenheit...

Страница 126: ...housing fans which means this value is not relevant None Case 4 Displays the fan speed of housing fan 4 Information The APC820 only has 2 housing fans which means this value is not relevant None Figu...

Страница 127: ...4 IRQ 5 IRQ 6 IRQ 7 IRQ 10 IRQ 11 IRQ 12 Selected interrupt is assigned COM C Setting of the COM port for the touch screen on the monitor panel connector Disabled Disables the interface Enabled Enable...

Страница 128: ...ot priority list allows to select from a list of currently detected 1st Boot Device devices 2nd Quick Boot Enabled Quiet Boot Disabled Automatic Boot List Retry Disabled AddOn ROM Display Mode Keep Cu...

Страница 129: ...for the ROM during the booting procedure Force BIOS An additional BIOS part can be displayed Keep current BIOS information is displayed Hold on errors This option sets whether the system should pause...

Страница 130: ...ctor is accessed through a program or virus Information With this option only the boot sector is protected not the entire hard drive Disabled Disables this function Enabled Enables this function Hard...

Страница 131: ...DD user password This function makes it possible to use the user password to change or configure each hard drive without having to reboot the device A user password allows the user to edit only certai...

Страница 132: ...sword This function makes it possible to use the user password to change or configure each hard drive without having to reboot the device Enter Enter password Table 87 945GME Hard Disk Security Master...

Страница 133: ...llows you to set the energy saving mode for the hard drive Disabled Do not switch off the hard drive Standby Monitor goes to standby mode Suspend Hard drive goes to suspend mode Keyboard PS 2 mouse Th...

Страница 134: ...MONITOR Activities in the IRQ of specific connections or devices return the system to its normal state from power saving mode IGNORE Activities are ignored Secondary Slave IDE The monitoring of activi...

Страница 135: ...which the user can no longer remember changes can be reset as long as they haven t been saved OK cancel Load CMOS defaults This item loads the CMOS default values which are defined by the DIP switch s...

Страница 136: ...the different CMOS profile switch position Yellow highlighted settings are variations in the BIOS default profile profile 0 Figure 60 BIOS default settings CMOS switch Information The switch position...

Страница 137: ...ofile 0 Profile 3 My setting ACPI Aware O S Yes Yes ACPI Version Features ACPI v2 0 ACPI v2 0 ACPI APIC support Enabled Enabled Suspend mode S1 POS S1 POS USB Device Wakeup from S3 S4 Disabled Disable...

Страница 138: ...CI2 Auto Auto PIRQ B PCIEX1 ETH1 Auto Auto PIRQ C PCIEX2 IF slot Auto Auto PIRQ D SATA UHCI1 SMB PCIEX3 Auto Auto PIRQ E INTD PATA UHCI3 Auto Auto PIRQ F INTA POWERLINK Auto 5 PIRQ G INTB CAN Timer Au...

Страница 139: ...Auto Auto Boot Display Preference SDVO B SDVO C LFP SDVO B SDV0 C LFP Local Flat Panel Type Auto Auto Local Flat Panel Scaling Centering Centering SDVO Port B Device DVI DVI SDVO Port C Device DVI No...

Страница 140: ...configuration profile setting overview Setting View Profile 0 Profile 3 My setting Onboard Audio Controller AC97 Disabled Table 98 945GME Advanced I O Interface Configuration profile setting overview...

Страница 141: ...ode Auto Auto Block multi sector transfer Auto Auto PIO mode Auto Auto DMA mode Auto Auto S M A R T Auto Auto 32Bit data transfer Enabled Enabled Secondary IDE master Type Auto LBA Large mode Auto Blo...

Страница 142: ...peed BIOS EHCI hand off Disabled Disabled USB beep message Enabled Enabled USB stick default emulation Hard disk Hard disk USB mass storage reset delay 20 Sec 20 Sec Table 101 945GME Advanced USB conf...

Страница 143: ...oard Center Baseboard In Power supply IF slot Case 1 Case 2 Case 3 Case 4 Legacy devices COM A Enabled Enabled Base I O address 3F8 3F8 Interrupt IRQ4 IRQ4 COM B Enabled Enabled Base I O address 2F8 2...

Страница 144: ...device Secondary slave Disabled Quick boot Enabled Enabled Quiet boot Disabled Disabled Automatic boot list retry Disabled Disabled AddOn ROM display mode Keep current Keep current Hold on errors Disa...

Страница 145: ...uspend Hard disk power down mode Suspend Suspend Keyboard PS 2 mouse MONITOR MONITOR FDC LPT COM ports MONITOR MONITOR Primary Master IDE MONITOR MONITOR Primary Slave IDE MONITOR MONITOR Secondary Ma...

Страница 146: ...ocessor defect Send industrial PC to B R for checking 6 x short 8042 gate A20 failure Keyboard controller defect block 8042 A20 gate Processor cannot switch to protected mode Send industrial PC to B R...

Страница 147: ...f ACPI Aware OS is set to YES in the setup TOM 8 MB 192 kB TOM 192 kB N A VGA frame buffer3 3 The VGA frame buffer can be reduced to 1 MB in the setup 1024 kB TOM 8 MB 192 kB 100000h N A Extended memo...

Страница 148: ...Video system 03E8h 03EFh COM3 03F6h 03F6h Primary IDE channel command port 03F7h 03F7h Primary IDE channel status port 03F8h 03FFh COM1 0480h 04BFh Motherboard resources 04D0h 04D1h Motherboard resou...

Страница 149: ...etting Optional setting IRQ 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 NMI NONE System timer Keyboard IRQ cascade COM1 Serial port A COM2 Serial port B ACPI1 1 Advanced Configuration and Power Interface Re...

Страница 150: ...ation and Power Interface Real time clock Coprocessor FPU Primary IDE channel Secondary IDE channel B R COM3 COM C PIRQ A 2 2 PIRQ A for PCIe UHCI Host Controller 2 VGA controller PCI Express root por...

Страница 151: ...this case devices cannot be connected to the USB interfaces USB2 and USB4 PIRQ A APIC IRQ16 CPU module UHCI 3 B0 D29 F3 VGA B0 D2 F0 B0 D2 F1 PIRQ B APIC IRQ17 PIRQ C APIC IRQ18 PIRQ D APIC IRQ19 PIR...

Страница 152: ...RQ C APIC IRQ18 PIRQ D APIC IRQ19 PIRQ E APIC IRQ20 Root 0 4 PCI EX Root 1 5 PCI EX Root 2 PCI EX UHCI 1 B0 D29 F1 PIRQ F APIC IRQ21 PIRQ G APIC IRQ22 UHCI 0 B0 D29 F0 PIRQ H APIC IRQ23 EHCI B0 D29 F7...

Страница 153: ...or components to the BIOS setup information about changes can be found in the Readme files of the BIOS upgrade 2 1 1 What information do I need Before you begin the upgrade it helps to determine the...

Страница 154: ...rd panel features Figure 63 Software version Advanced Baseboard Panel Features Versions Panel Control BIOS R110 MTCX PX32 V0 06 MTCX FPGA V0 03 CMOS Profil 0h Device ID 0000AC7h Compatibility ID 0000h...

Страница 155: ...yed when an Automation Panel is connected TBD Figure 64 Firmware version of the AP Link SDL transmitter Advanced Panel Control Panel 0 14 connected to Automation Panel Link or Monitor Panel connector...

Страница 156: ...t after 5 seconds Concerning point 2 Return to the shell MS DOS The system must be rebooted after a successful upgrade Reboot and press Del to enter the BIOS setup menu and load the setup defaults the...

Страница 157: ...the disk drive Open Windows Explorer Right click on the 3 Floppy icon and select Format Then select the checkbox Create an MS DOS startup disk press Start and acknowledge the warning message with OK...

Страница 158: ...kette In the Explorer go to the Tools menu select Folder Options and open the View tab now deactivate the option Hide protected operating system files Recommended activated as default and activate the...

Страница 159: ...rive B R Industrial PC USB Media Drive B R Embedded OS Installer V3 00 or higher 2 3 2 Procedure Connect the USB flash drive to the PC If the drive list is not refreshed automatically the list must be...

Страница 160: ...o I get MS DOS Information concerning creating an MS DOS boot diskette can be found in section 2 2 Creating an MS DOS boot diskette in Windows XP on page 157 Then the files from the diskette are to be...

Страница 161: ...R Industrial PC B R Embedded OS Installer V3 10 or higher 2 4 2 Procedure Insert the CompactFlash card in the CF slot on the industrial PC If the drive list is not refreshed automatically the list mu...

Страница 162: ...diskette can be found in section 2 2 Creating an MS DOS boot diskette in Windows XP on page 157 Then the files from the diskette are to be copied to your hard drive 2 5 Upgrade problems Potential upg...

Страница 163: ...gure 72 Automation PC 820 with MS DOS Model number Short description Note 9S0000 01 010 OEM MS DOS 6 22 German disk OEM MS DOS 6 22 German disks Only delivered with a new PC 9S0000 01 020 OEM MS DOS 6...

Страница 164: ...pths on the Monitor Panel connector with 945GME CPU boards Resolutions for DVI Color depth 8 bit 16 bit 24 bit 640 x 480 800 x 600 1024 x 768 1280 x 1024 Resolutions for RGB Color depth 8 bit 16 bit 2...

Страница 165: ...XP Professional Service Pack 3 CD multi language Only available with a new device A CompactFlash card is required for operation This is not included in delivery and must be ordered separately 5SWWXP...

Страница 166: ...CompactFlash card All of the drivers required for operation graphics network etc are also installed when doing so 4 2 Drivers The latest drivers for all released operating systems can be found in the...

Страница 167: ...required by the respective device are included Windows XP Embedded is also based on the same reliable code as Windows XP Professional It provides industry with leading reliability improvements in sec...

Страница 168: ...ile configurable Administrator account User account configurable Explorer shell Registry Filter Internet Explorer 6 0 SP2 Internet information service IIS Terminal service Windows Firewall MSN Explore...

Страница 169: ...reinstalled on the operating system If an older driver version is installed the latest version can be downloaded from the B R homepage www br automation com and installed A potentially activated Enhan...

Страница 170: ...the display specific parameters of connected Panels Reading of device specific keys Activation of device specific LEDs on a foil keypad Figure 75 ADI Control Center Screenshots Examples Information T...

Страница 171: ...up Windows XP Embedded Content of B R Windows XP Embedded image Automation PC 810 Windows XP Professional Installation using its own setup Windows XP Embedded Content of B R Windows XP Embedded image...

Страница 172: ...to adjust the strength of the video signal to the SDL cable length This allows you to improve the visual representation on the display The SDL equalizer can be set under the Display tab under Settings...

Страница 173: ...unity characteristics information technology equipment ITE devices limits and methods of measurement EN 60060 1 High voltage test techniques part 1 General specifications and testing conditions EN 600...

Страница 174: ...ectrical fast transient burst immunity test EN 61000 4 5 Electromagnetic compatibility EMC part 4 5 Testing and measuring techniques surge immunity test EN 61000 4 6 Electromagnetic compatibility EMC...

Страница 175: ...ogy equipment ITE devices class A industrial areas EN 61131 2 Programmable logic controllers EN 50091 2 Uninterruptible power systems UPS class A 47 CFR Part 15 Subpart B Class A FCC Harmonic currents...

Страница 176: ...dB V Quasi peak value 60 dB V Average Other connections 150 kHz 500 kHz 97 87 dB V and 53 43 dB A Quasi peak value 84 74 dB V and 40 30 dB A Average Other connections 500 kHz 30 MHz 87 dB V and 43 dB...

Страница 177: ...easured at a distance of 10 m 47 dB V m Quasi peak value 47 dB V m Quasi peak value 47 dB V m Quasi peak value Test carried out according to EN 55011 EN 55022 Limits according to EN 61131 2 Limits acc...

Страница 178: ...EN 55024 Information technology equipment ITE devices Immunity to surge voltages EN 61000 4 5 EN 61000 6 2 Generic standard industrial areas EN 61800 3 Adjustable speed electric drives Part 3 EMC requ...

Страница 179: ...by activating configuration and control elements Criteria D Deterioration or failure of the function which can no longer be established operating equipment destroyed 4 1 Electrostatic discharge ESD Te...

Страница 180: ...litude modulation with 1 kHz length 3 seconds criteria A 80 MHz 1 GHz 1 4 2 GHz 10 V m 80 amplitude modulation with 1 kHz length 3 seconds criteria A 800 960 MHz GSM 10 V m pulse modulation with 50 du...

Страница 181: ...g I O 1 kV Criteria B 1 kV Criteria B Test carried out according to EN 61000 4 4 Limits according to EN 61000 6 2 AC power I O 2 kV Criteria B AC power inputs AC power outputs DC power I O 10 m 1 2 kV...

Страница 182: ...O 150 kHz 80 MHz 10 V 80 amplitude modulation with 1 kHz length 3 seconds criteria A 150 kHz 80 MHz 3 V 80 amplitude modulation with 1 kHz length 3 seconds criteria A 150 kHz 80 MHz 3 V 80 amplitude m...

Страница 183: ...ion z test in the field of an induction coil 1 m x 1 m 30 A m criteria A 30 A m criteria A 50 Hz 1 A m criteria A Table 130 Test requirements Magnetic fields with electrical frequencies Test carried o...

Страница 184: ...ions Test carried out according to EN 61000 4 12 Limits according to EN 61131 2 Power I O L to L 1 kV 1 MHz repeat rate 400 seconds length 2 seconds connection lengths 2 m criteria B Power I O L to PE...

Страница 185: ...60721 3 2 class 2M3 Toppling packaged EN 60068 2 31 EN 60721 3 2 class 2M1 EN 60721 3 2 class 2M2 EN 60721 3 2 class 2M3 Free fall packaged EN 60068 2 32 EN 61131 2 Programmable logic controllers Tab...

Страница 186: ...z Acceleration 1 5 g 200 500 Hz Acceleration 4 g Limits according to EN 61800 2 10 sweeps for each axis packaged Frequency Limit value 2 9 Hz Amplitude 3 5 mm 9 200 Hz Acceleration 1 g 200 500 Hz Acce...

Страница 187: ...100 kg Yes 20 100 kg Yes 100 kg 100 kg 100 kg Yes Table 138 Test requirements Toppling Test carried out according to EN 60068 2 32 Limits according to EN 61131 2 Limits according to EN 60721 3 2 class...

Страница 188: ...able logic controllers Table 140 Overview of limits and testing guidelines for temperature and humidity Test carried out according to UL 508 Limits according to UL 508 Limits according to EN 61131 2 W...

Страница 189: ...unit is occasionally supplied with voltage during testing duration approximately 30 hours Closed devices These are devices whose data sheet specifies a surrounding housing enclosure with the correspon...

Страница 190: ...g of electrical devices Overload UL 508 EN 61131 2 Programmable logic controllers UL 508 Industrial control equipment Simulation component defect UL 508 EN 61131 2 Programmable logic controllers UL 50...

Страница 191: ...ainst over voltage can be removed before the test Input voltage Test voltage Input voltage Test voltage 1 2 50 s voltage surge peak AC 1 min DC 1 min AC 1 min DC 1 min 0 50 VAC 0 60 VDC 850 V 510 V 72...

Страница 192: ...es 1 5 IN 1 sec on 9 sec off Table 154 Test requirements Overload Test carried out according to UL 508 Limits according to EN 61131 2 Limits according to UL 508 Simulation of how components in power s...

Страница 193: ...coordination for equipment within low voltage systems part 1 Principles requirements and tests Table 157 Overview of limits and testing guidelines for other tests Test carried out according to Limits...

Страница 194: ...anizations such as UL CSA FCC VDE VE etc We give special consideration to the reliability of our products in an industrial environment Certifications USA and Canada All important B R products are test...

Страница 195: ...nd IDE ATA interface 5CFCRD 8192 04 CompactFlash 8192 MB B R CompactFlash card with 8192 MB SLC NAND flash and IDE ATA interface 5CFCRD 0064 03 CompactFlash 64 MB SSI CompactFlash card with 64 MB SLC...

Страница 196: ...TB704 91 0TB704 91 4 pin cage clamps Table 160 Order data 0TB704 9 and 0TB704 91 Information The following characteristics features and limit values only apply to this accessory and can deviate from t...

Страница 197: ...50 mAh button cell Table 162 Order data Lithium batteries Information The following characteristics features and limit values only apply to this accessory and can deviate those specified for the entir...

Страница 198: ...r 5AC900 1000 00 This adapter enables a standard monitor to be connected to the DVI I interface 4 1 Order data Model number Description Figure 5AC900 1000 00 Adapter DVI A m to CRT DB15HD f Adapter DV...

Страница 199: ...ring system startup that are caused by the different boot times See chapter 3 Commissioning section 3 Known problems issues on page 82 Information The 5CFCRD xxxx 04 CompactFlash cards are supported o...

Страница 200: ...cesses Data retention 10 years Lifetime monitoring Yes Supported operating modes PIO Mode 0 6 Multiword DMA Mode 0 4 Ultra DMA Mode 0 4 Continuous reading Typically 35 MB s 240X 1 2 Max 37 MB s 260X 1...

Страница 201: ...ort 0 to 70 C 65 to 150 C 65 to 150 C Relative humidity Operation Storage Transport Max 85 at 85 C Vibration Operation Storage Transport 20 G peak 20 2000 Hz 4 in each direction JEDEC JESD22 method B1...

Страница 202: ...mensions CompactFlash card Type I 0 0 10 20 30 40 50 60 70 80 90 80 70 60 50 40 30 20 10 5 10 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 Temperature C Relative humidity RH non condensing 1...

Страница 203: ...ATTO disk benchmark v2 34 comparison writing 5 10 15 20 25 30 35 40 0 5 1 2 4 8 16 32 128 64 256 512 1024 2048 4096 8192 Transfer rate MB s Transfer size kb 5CFCRD 4096 03 5CFCRD 4096 04 5CFCRD 0512...

Страница 204: ...startup that are caused by the different boot times See chapter 3 Commissioning section 3 Known problems issues on page 82 Information On Windows CE 5 0 devices 5CFCRD xxxx 03 CompactFlash cards up t...

Страница 205: ...03 5CFCRD 0256 03 5CFCRD 0512 03 5CFCRD 1024 03 5CFCRD 2048 03 5CFCRD 4096 03 5CFCRD 8192 03 MTBF at 25 C 4 000 000 hours Maintenance None Data reliability 1 unrecoverable error in 1014 bit read acces...

Страница 206: ...ature Operation Bearings Transport 0 to 70 C 50 to 100 C 50 to 100 C Relative humidity Operation Storage Transport 8 to 95 non condensing Vibration Operation Storage Transport max 16 3 g 159 m s2 0 pe...

Страница 207: ...C 820 User s Manual V 1 00 6 4 Dimensions Figure 82 Dimensions CompactFlash card Type I Top 26 50 1 25 1 60 0 05 1 01 0 07 1 01 0 07 0 99 0 05 4 x R0 5 0 1 3 30 0 1 2x 12 0 10 2x 25 78 0 07 1 65 42 8...

Страница 208: ...Order data Information We reserve the right to supply alternative products due to the vast quantity of flash drives available on the market and their corresponding short product lifecycle Therefore t...

Страница 209: ...x 8 7 MB second Max 1 7 MB second To each USB type A interface MTBF at 25 C 100000 hours Data retention 10 years Maintenance None Operating system support Windows CE 4 2 CE 5 0 ME 2000 XP and Mac OS 9...

Страница 210: ...meters above sea level Environmental characteristics 5MMUSB 2048 00 Altitude Operation Bearings Transport 3048 m 12192 m 12192 m Figure 83 Temperature humidity diagram USB flash drive 5MMUSB 2048 00...

Страница 211: ...g a bootable USB flash drive B R USB flash drive B R Industrial PC USB floppy drive external USB keyboard A start disk created using MS DOS 6 22 or Windows 98 1 44MB HDD Windows Millennium NT4 0 2000...

Страница 212: ...212 Commissioning USB flash drive Automation PC 820 User s Manual V 1 00...

Страница 213: ...le 4A0006 00 000 1 pc and 0AC201 91 4 pcs Information The product design allows the battery to be changed with the APC820 switched either on or off In some countries safety regulations do not allow ba...

Страница 214: ...ection not the power supply in order to discharge any electrostatic charge from your body Remove the black plastic cover from the battery compartment and carefully pull out the battery using removal s...

Страница 215: ...make the next battery change easier be sure the removal strip is in place when inserting battery Reconnect the APC820 to the ACOPOSmulti rail and press the power button Date and time might need to be...

Страница 216: ...he housing or ground connection not the power supply in order to discharge any electrostatic charge from your body Remove the fan from the holder To do this simply press the snap arms inward and caref...

Страница 217: ...MI and reset handling Temperature monitoring Fan control Key and LED handling coordination matrix keyboard on B R display units Advanced desktop operation keys USB forwarding Daisy chain display opera...

Страница 218: ...Manual V 1 00 Status LEDs CF Link The functions of the MTCX can be expanded via Firmware upgrade1 The version can be read in BIOS or in Microsoft Windows XP embedded using B R Control Center 1 Can be...

Страница 219: ...application individually Features Configuration of normal keys like on a keyboard A B C etc Keyboard shortcuts CTRL C SHIFT DEL etc on one key Special key functions change brightness etc Assign functi...

Страница 220: ...Power Panel 65 Power Panel 100 200 Power Panel 300 400 Mobile Panel 40 50 Mobile Panel 100 200 Provit 2000 Provit 5000 A detailed guide for configuring keys and LEDs can be found in the B R Key Edito...

Страница 221: ...y included in the B R embedded operating system APC Abbreviation for Automation PC API Abbreviation for Application Program Interface The interface which allows applications to communicate with other...

Страница 222: ...able memory or fast buffer memory It is used to relieve the fast main memory of a computer For example data that should be output to slower components by the working memory e g disk storage printers i...

Страница 223: ...to COM2 COM3 Device name for a serial port in a PC system The input output area for COM3 is usually found at address 03E8H Generally the COM3 port is assigned to IRQ 4 In many systems COM3 is used as...

Страница 224: ...n a line from top to bottom In order to prevent flickering the screen content is updated at least 25 times per second The sharpness of the picture is determined by the number of pixels on the screen C...

Страница 225: ...to indicating its readiness for processing DSR is a hardware signal which is sent via line number 6 in compliance with the RS 232 C standard DTR An abbreviation for Data Terminal Ready A signal used i...

Страница 226: ...logy eXtended This established standard offers complete PC functionality on a very compact form factor of just 114 mm x 100 mm 4 5 x 4 The flexibility offered by ETX in the development of system speci...

Страница 227: ...splay FTP File Transfer Protocol Rules for transferring data over a network from one computer to another computer This protocol is based on TCP IP which has established itself as the standard for tran...

Страница 228: ...word isos meaning equal www iso ch Jitter Jitter is a term that describes time deviations of cyclic events If for example an event should take place every 200 s and it actually occurs every 198 to 20...

Страница 229: ...vice PRN in MS DOS the logical device name for the printer The abbreviation LPT stands for Line Printer Terminal MB Megabyte 1 MB 220 or 1 048 576 bytes Microprocessor Highly integrated circuit with t...

Страница 230: ...latform that provides a common runtime library and type system for all programming languages DOTNET is the umbrella term for the following products strategies and technologies NET Framework a new soft...

Страница 231: ...test PC generation It is basically a synchronous bus The main clock of the CPU is used for synchronization The PCI bus is microprocessor independent 32 bit and 64 bit compatible and supports both 3 3...

Страница 232: ...devices generally the monitor If the POST runs successfully control is transferred over to the system s bootstrap loader Power Panel Power Panel is part of the B R product family and is a combination...

Страница 233: ...PCs It is divided into the following products IPC5000 IPC5600 IPC5000C IPC5600C and the display units belonging to them PV Process variable Logical storage location for values and states in a program...

Страница 234: ...alanced operation increased immunity to disturbances High level 2 6 V low level 2 6 V 4 wire connection inverted not inverted cable lengths up to 1200 m transfer rates up to 10 Mbit s 1 sender can car...

Страница 235: ...s full PLC functionality On the PC it is coupled via a DPR with the process using a fieldbus connection It is programmed externally or using the host PC SoftPLC Synonym for SoftPLC SRAM An abbreviatio...

Страница 236: ...that has become the generally accepted standard for data exchange in heterogeneous networks TCP IP is used both in local networks for communication between various computer and also for LAN to WAN ac...

Страница 237: ...B An abbreviation for Universal Serial Bus A serial bus with a bandwidth of up to 12 megabits per second Mbit s for connecting a peripheral device to a microcomputer Up to 127 devices can be connected...

Страница 238: ...200 pixels 16 10 WXGA Wide XGA generally 1280 768 pixels XGA An abbreviation for EXtended Graphics Array An expanded standard for graphics controllers and monitors that was introduced by IBM in 1990 T...

Страница 239: ...NK card 2 port 5ACPCC MPL0 00 72 Figure 22 POWERLINK card 2 port node number switch 74 Figure 23 Installation 75 Figure 24 Swivel range of the front cover 78 Figure 25 Attaching modules 79 Figure 26 T...

Страница 240: ...igure 68 Creating a bootable diskette in Windows XP step 4 158 Figure 69 Creating a bootable diskette in Windows XP step 5 158 Figure 70 Creating a USB flash drive for B R upgrade files 160 Figure 71...

Страница 241: ...able 20 RS232 Bus length and transfer rate 46 Table 21 RS232 Cable requirements 46 Table 22 Pin assignments COM2 48 Table 23 RS232 422 485 I O address and IRQ 48 Table 24 RS232 Bus length and transfer...

Страница 242: ...onfiguration setting options 105 Table 70 945GME Advanced Clock Configuration setting options 105 Table 71 945GME Advanced IDE Configuration setting options 106 Table 72 945GME Primary IDE Master sett...

Страница 243: ...Table 116 Model numbers Windows XP Professional 165 Table 117 Model numbers Windows XP Embedded 167 Table 118 Device functions in Windows XP Embedded with FP2007 168 Table 119 System support ADI drive...

Страница 244: ...ements Leakage current 192 Table 154 Test requirements Overload 192 Table 155 Test requirements Defective component 192 Table 156 Test requirements Voltage range 192 Table 157 Overview of limits and t...

Страница 245: ...5 204 5CFCRD 1024 04 20 195 199 5CFCRD 2048 03 21 195 204 5CFCRD 2048 04 20 195 199 5CFCRD 4096 03 21 195 204 5CFCRD 4096 04 21 195 199 5CFCRD 8192 03 21 195 204 5CFCRD 8192 04 21 195 199 5MMDDR 0512...

Страница 246: ...Model number index 246 Automation PC 820 User s Manual V 1 00...

Страница 247: ...r 121 CPU configuration 101 Exit 135 Graphics configuration 97 Hard disk security master password 132 Hard disk security user password 131 I O interface configuration 104 IDE Configuration 106 Keyboar...

Страница 248: ...up 224 Dimension standards 18 Dimensions 1 card slot 35 DIMM 224 Disposal 17 Distribution of resources I O address assignment 148 RAM address assignment 147 DMA 224 Dongle 62 DRAM 225 Dry cold 188 Dry...

Страница 249: ...227 Interfaces 27 43 International Certifications 194 ISA 228 ISO 228 J Jitter 228 Jumper 228 K Key editor 219 Keypad modules 228 L LCD 228 Leakage current 192 LED 229 Lithium battery 61 Low speed 44...

Страница 250: ...5 PROFIBUS DP 233 Programs 17 Protection type 193 Provit 220 233 Provit 2000 233 Provit 5000 233 PV 233 Q QUXGA 233 QVGA 233 QWUXGA 233 QXGA 235 R RAM 233 Real time 234 Real time clock 61 65 Replaceme...

Страница 251: ...SXGA 236 SXGA 236 T Task 236 TCP IP 236 Technical data 23 1 card slot 32 CPU board 65 Ethernet card 10 100 1000 70 Main memory 66 Power supply with heat sink 67 POWERLINK card 2 port 72 Replacement f...

Страница 252: ...Index 252 Automation PC 820 User s Manual V 1 00 Windows XP Embedded 167 Touch screen driver 169 Windows XP Professional 165 Worst case 188 WSXGA 238 WUXGA 238 WXGA 238 X XGA 238 XTX 238...

Отзывы: