background image

© BQT Solutions (SEA) Pte Limited 

 

 

             Page 2 

1. 

DESCRIPTION 

 

The  COBALT  is  a  motor  driven  low  voltage  electric  lock  designed  to  secure  commercial  and  residential  swing 
through  doors.  It  is  supplied  with  a  matching  strike  plate  and  can  be  surface  mounted  with  the  aid  of  available 
accessories,  or  installed  into a  mortise  for  a  concealed  solution.  The  lock  has  been  designed  to address  the  two 
biggest issues in concealed electric locking today;   

 

1. 

The ability to ‘pull’ a door into alignment even if the door has not closed in a central position.  

2.  The ability to release when requested even if there is excessive load on the door. 

 
The  design  of  the  COBALT  is  unique  as  it  has  two  motors  which  independently  operate  two  locking  pins.  These 
dual bolt pins offer extra strength but more importantly ensure the door can be secured even when the door has not 
closed  in  the  correct  position.  This  is  achieved  by  the  lock  sensing  which  direction  the  door  is  closing  from  and 
activating the appropriate bolt pin to ‘grab’ the door and pull it into alignment before the other bolt pin activates. A 
door that is 8mm off alignment in either direction (16mm total window) will be secured with the COBALT. 
 
With the door secured and locked the COBALT can be given an unlock signal and it will instantly unlock. If the door 
is  loaded  (pre-load)  when  the  unlock  signal  is  given  the  COBALT  will  still  unlock,  even  with  loads  in  excess  of 
100Kg  on  the  door.  Critically  the  ability  of  the  COBALT  to  instantly  release  with  excessive  pre-load  on  the  door 
even occurs in the event of a power failure if the lock is configured as fail safe. 
 
Additional features of the COBALT are; 
 

 

Multi-voltage input (12-24VDC)  

 

Very low current consumption 

 

Door position and Bolt position monitors 

 

High physical strength 

– 10,000N holding force 

 

Fail safe / fail secure on site conversion with the re-positioning of a single jumper 

  
 
 

2. PRODUCT UNBOXED 

 

Along  with  the  COBALT  and  matching  strike  there  are  also  10G  Self 
Tapping  and  M5  Machine  Screws  supplied.  Four  fitting  tabs  are  also 
enclosed  and  can  be  used  in  conjunction  with  the  M5  screws  for 
recessing the lock or strike plate to metal doors and frames.  
 
The 7 way wire loom supplied is used to ease installation as the wiring 
can be done without the lock being installed until the very end.  
 
 
 
 
 
 
 
 

 

              

 

           

 
 
 
   

  Wire Loom 

 
                 

 

 

  
  Mounting Screws              Fitting Tabs            

 

            Strike Plate 

       Lock 

            

 
 

Содержание YD30 Cobalt

Страница 1: ...YD30 COBALT INSTALLATION AND OPERATING INSTRUCTIONS ...

Страница 2: ...NT o 4 1 Mechanical o 4 2 Electrical 5 INSTALLATION o 5 1 Mortise Installation o 5 2 Surface installation 6 WIRING o 6 1 Fail Safe connection o 6 2 Fail Secure connection o 6 3 Jumper position 7 OPERATION o 7 1 Fail Safe Operation o 7 2 Fail Secure Operation 8 SPECIFICATIONS 9 MAINTENANCE 10 WARRANTY 11 UPGRADE Pg 2 Pg 2 Pg 3 3 3 3 3 3 Pg 4 4 4 Pg 4 4 6 Pg 8 8 8 9 Pg 9 9 9 Pg 10 Pg 10 Pg 10 Pg 10 ...

Страница 3: ...vates A door that is 8mm off alignment in either direction 16mm total window will be secured with the COBALT With the door secured and locked the COBALT can be given an unlock signal and it will instantly unlock If the door is loaded pre load when the unlock signal is given the COBALT will still unlock even with loads in excess of 100Kg on the door Critically the ability of the COBALT to instantly...

Страница 4: ... BQT Solutions SEA Pte Limited Page 3 3 DIMENSIONS 3 1 Lock 3 2 Strike Plate 3 3 Fitting Tab 3 4 Housing Available separately 3 5 Dress Plate Available separately ...

Страница 5: ...t position feedback These optional connections can be integrated into access control or alarm systems to provide full monitoring The correct gauge of wire needs to be chosen as voltage drop across the power wires and can limit the locks operation For all the remaining connections a lower gauge wire can be used as these are only signal wires The following chart shows the maximum distance that the p...

Страница 6: ...e made to the supplied wire loom which in turn plugs into the lock The jumper needs to be positioned for fail safe fail secure configuration as per the instructions on the lock cover The Red Black and Blue wires are essential connections whilst the Violet and White are optional Detailed wiring instructions can be found in Section 6 5 1 3 Fitting the lock and strike plate The lock is slid back into...

Страница 7: ...ing determine exactly where the wiring will enter the housing and drill one or two 8mm holes through the housing wall Ensure the holes are on the housing face that goes against the wooden frame Push the supplied grommet s into the drilled hole s The two 10G Hex head self tapping screws supplied with the housing can then be screwed into the wood but not tightened The two keyhole shaped cut outs in ...

Страница 8: ...glass to give a clean finish The protective coating on the dress plate can be removed once it is in place 5 2 5 Fitting the strike plate into the housing The strike plate is placed into the housing and secured in place with the supplied M5 machine screws 5 2 6 Checking the operation With the lock and strike installed and wiring complete the door is closed to check the alignment and operation The k...

Страница 9: ...s open Door Position Switch WHITE COM 6 1 Fail Safe Connection When wiring the COBALT the positive voltage is connected to RED negative is connected to BLACK and a switched positive voltage wire connected to BLUE In Fail Safe configuration applying voltage to the COBALT signals it to lock The lock signal in Fail Safe configuration is active high 6 2 Fail Secure Connection When wiring the COBALT th...

Страница 10: ...ong as the door is open but will instantly re lock when voltage is applied to the BLUE wire and the door is closed In the event of a power failure voltage is removed from the BLUE wire and the COBALT unlocks 7 2 Fail Secure Operation Assume the lock is installed and wired the door is open and voltage is removed from the BLUE wire As the door closes the COBALT senses the door approaching and activa...

Страница 11: ...rating Current after initial power up is 250mA 12VDC and 200mA 24VDC 9 MAINTENANCE The COBALT has been lubricated at assembly and applying any other type of lubricant may void the warranty Removing the lock cover may void the warranty A dry cloth can be used to polish the stainless steel face plate and strike plate as required 10 WARRANTY The COBALT is covered with a manufacturers 12month warranty...

Страница 12: ... BQT Solutions SEA Pte Limited Page 11 NOTES Version 3 0 ...