background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

         

 
 
 
 
 
 
 
 

YD30M   

COBALT-mini

    

 

INSTALLATION AND OPERATING INSTRUCTIONS 

       

 

 

      

 

Содержание COBALT-mini YD39M

Страница 1: ...YD30M COBALT mini INSTALLATION AND OPERATING INSTRUCTIONS...

Страница 2: ...T o 4 1 Mechanical o 4 2 Electrical 5 INSTALLATION o 5 1 Mortise Installation o 5 2 Surface installation 6 WIRING o 6 1 Fail Safe connection o 6 2 Fail Secure connection o 6 3 Jumper position 7 OPERAT...

Страница 3: ...sition With the door secured and locked the COBALT mini can be given an unlock signal and it will instantly unlock If the door is loaded pre load when the unlock signal is given the COBALT mini will s...

Страница 4: ...BQT Solutions SEA Pte Limited Page 3 3 DIMENSIONS 3 1 Lock 3 2 Strike Plate 3 3 Fitting Tab 3 4 Housing Available separately 3 5 Dress Plate Available separately...

Страница 5: ...e door is approaching from the right then the bolt pin is at the bottom as indicated below 4 2 Electrical The first consideration is to establish where to run the wires and decide on what feedback is...

Страница 6: ...the supplied fitting tabs can be used to secure the lock and strike plate in place The mortise behind the lock body needs to have enough space to accommodate the wiring 5 1 2 Wiring the lock Wires ar...

Страница 7: ...determine exactly where the wiring will enter the housing and drill one or two 8mm holes through the housing wall Ensure the holes are on the housing face that goes against the wooden frame Push the...

Страница 8: ...glass to give a clean finish The protective coating on the dress plate can be removed once it is in place 5 2 5 Fitting the strike plate into the housing The strike plate is placed into the housing a...

Страница 9: ...Door Position Switch WHITE COM 6 1 Fail Safe Connection When wiring the COBALT mini the positive voltage is connected to RED negative is connected to BLACK and a switched positive voltage wire connec...

Страница 10: ...ng as the door is open but will instantly re lock when voltage is applied to the BLUE wire and the door is closed In the event of a power failure voltage is removed from the BLUE wire and the COBALT m...

Страница 11: ...t after initial power up is 250mA 12VDC and 200mA 24VDC 9 MAINTENANCE The COBALT mini has been lubricated at assembly and applying any other type of lubricant may void the warranty Removing the lock c...

Страница 12: ...BQT Solutions SEA Pte Limited Page 11 NOTES Version 3 0...

Отзывы: