3
SW2
P1
SW1
6
8
7
3 -
Wait for the note confirming the
operation (approximately 3÷15 s).
The number of confirmation signals
also indicates the number of present
and programmed entry panels (1
signal for the main entry panel and 1
signal for each secondary entry panel).
4 -
Refit jumper SW1.
Programming receivers
1 -
Remove jumper SW2 from any
entry panel.
2 -
Lift the handset of the receiver to
be programmed (for telephone sets,
see the instructions featured in inter-
face IT/300).
3 -
Press the door-lock release and
auxiliary 2 buttons at the same time
for at least 1 s (when audio towards
the entry panel is enabled, the ope-
ration is confirmed).
4 -
On the entry panel, press the call
button the receiver is to be associa-
ted with.
5 -
Replace the handset.
6 -
Repeat the operation from point 2
on for all remaining receivers.
7 -
Refit jumper SW2 to exit program-
ming.
WARNING. The programming pro-
cedure for the VSE/301 selector,
where fitted, must only be perfor-
med once you have programmed
which calls from the entry panels
are to be associated with which
receivers.
In installations with XA/300LR we
recommend you gather up the
receiver’s ID (SN) codes, applied
on the outside of the housing, and
enter them in the tables that come
with the XA/300LR and IPC/300LR.
NOTE. Once the power supplier
has been programmed using a
PCS/300 unit, it will no longer be
possible to gain access to the
entry panel standard program-
ming.
To restore default conditions, plea-
se refer to the related chapter.
Return to default conditions from
entry panel
1 -
Remove the SW1 jumper.
2 -
Close the earthed door open con-
tact.
A sound signal confirms that the ope-
ration has occurred.
3 -
Replace the SW1 jumper
COLOUR VIDEO
ENTRY PANEL HEVC/301
Video entry panel complete with
colour CCD camera and white-light
LED for lighting the target area.
Its features and functions are similar
to those of entry panel HEV/301.
Technical features
• Power supply:
14÷18 V DC.
• Current demand:
- on stand-by with 14V DC max. 230
mA;
- operating with 14V DC max. 380
mA;
- with door-lock release activated,
add 500 mA;
- for each HEP/306-HEP/312D, add
35 mA;
- for each XDV/300A connected,
add 40 mA;
- for 64 receivers, add 64 mA.
• Secrecy of speech/privacy of video
signal.
• Door-lock release command: pulse-
type for solenoid lock at 12 V 1 A.
• Timed solenoid door-lock release:
adjustable in the range 1 to 15 s.
• Installation activation time: 60 s.
be sent along a telephone-type sin-
gle twisted pair line.
An additional three video-entry or
audio-only entry panels can be
added to the first in series without the
need for other equipment (selectors,
distributors).
The entry panel comes ready to
house the KHSO luminous system
busy warning kit and 1 KHPS (or 1
KHPD) call kit.
The entry panel comes complete with:
- CCD camera with ±11° manual
angle adjustment both horizontally
and vertically (fig. 4), with fixed-focus
lens (see fig. 5 for dimensions of the
target area);
- phonic unit;
- infrared LED for lighting the target
area;
- three potentiometers for the fol-
lowing functions (fig. 4-6):
volume control at entry panel;
volume control at receiver;
P1
timed (in the range 1 to 15 s) sole-
noid door-lock release.
The entry panel comes with system
busy and door-lock release buzzer.
The wires supplied make it simple to
connect the entry panel’s various
component units.
Function of each terminal
14-18V DC
power supply
solenoid lock output
door-lock release button
–
earth for solenoid lock
auxiliary command 1 output
auxiliary command 2 output
entry panel enabling output
B IN
bus input from other entry
panels
B OUT
bus output towards recei-
vers or other entry panels
Connector functions
5-pin CN1 connector:
used for con-
nection to entry panel HEP/306 or
HEP/312D.
3-pin CN3 connector:
used for con-
nection to buttons KHPS or KHPD.
1-red:
to button n° 2.
2-orange:
to button n° 3.
3-yellow:
to button n° 4.
WARNING. In installations with a
number of entry panels, call buttons
must be arranged in the same order
on each.
Connector CN4:
comes ready con-
nected.
1-black:
to button no. 1.
2-brown:
to button no. 1.
3-green:
to LEDs lighting the buttons.
4-yellow:
to LEDs lighting the buttons.
5-pin CN5 connector:
used for con-
nection to KHSO luminous warning kit.
WARNING. Wires belonging to
cables that are not used must be
insulated.
Function of jumpers SW1 and SW2
(fig. 6)
SW1:
automatic programming of
number of entry panels (default set-
ting 1).
SW2:
programming of receivers.
Programming of number of entry
panels
(only required where there is
more than one entry panel)
1 -
Start with the last entry panel con-
nected in series to the bus (usually
the one with terminals
B IN
not con-
nected).
2 -
Remove jumper SW1.
Содержание HEV/301
Страница 23: ...3 SW2 P1 SW1 6 8 7 ...