Kodiak
Recirculating Chiller Technical Manual
Manual# 820-0043 Rev N, 11/25/2019
4
Safety Precautions
This system is designed to provide fluid cooling only as specified in this manual. If you use this
system in a manner other than as specified, the safety protection of the system may be impaired.
Warnings are posted throughout the manual. Read and follow these important instructions. Failure to
observe these instructions or use other than specified may impair safety protection, void the warranty,
and can result in permanent damage to the unit, significant property damage, personal injury and/or
death.
Make sure you read, understand, and follow all instructions and safety precautions listed in this
manual before operating your unit. If you have any questions concerning the operation of your unit or
the information in this manual, please contact our Applications Engineering Department at (781) 933-
7300.
If the set point is 10
o
C or below, a freezing point depression additive, such as ethylene
glycol, is required. This unit is equipped with a low flow switch. This feature will shut
the chiller down during a low flow situation to prevent freezing.
DO NOT USE AUTOMOTIVE ANTI-FREEEZE IN THE CHILLER. The rust
inhibitors in the automotive type will cause premature failure of the pump seals. Use of
automotive anti-freeze in a Boyd chiller will void the warranty.
Never place the unit in a location where excessive heat, moisture, or corrosive materials
are present.
The unit must be plugged into a properly grounded power source.
Do not connect the SUPPLY or RETURN fitting to your building water supply or any
pressurized source.
Performance of installation, operation, or maintenance procedures other than those
described in this manual may result in a hazardous situation and may void the Boyd
warranty.
Transport the unit with care. Sudden jolts or drops can damage the unit.
Observe all warning labels. Never remove warning labels.
Do not operate damaged or leaking equipment.
Do not operate the unit without fluid in the reservoir.
Always turn the unit "OFF" and disconnect the power cord from the power source
before performing any service, maintenance procedures, or before moving the unit.
Do not operate equipment with damaged power cords.
A qualified technician should perform Service and repairs.
Содержание AAVID Kodiak H02 Series
Страница 33: ...Kodiak Recirculating Chiller Technical Manual Manual 820 0043 Rev N 11 25 2019 32 Drawing Specifications RC006 ...
Страница 36: ...Kodiak Recirculating Chiller Technical Manual Manual 820 0043 Rev N 11 25 2019 35 Wiring Diagram RC006G02 ...
Страница 37: ...Kodiak Recirculating Chiller Technical Manual Manual 820 0043 Rev N 11 25 2019 36 Wiring Diagram RC011G02 ...
Страница 38: ...Kodiak Recirculating Chiller Technical Manual Manual 820 0043 Rev N 11 25 2019 37 Wiring Diagram RC011H02 J02 ...
Страница 39: ...Kodiak Recirculating Chiller Technical Manual Manual 820 0043 Rev N 11 25 2019 38 Wiring Diagram RC022H02 J02 ...
Страница 41: ...Kodiak Recirculating Chiller Technical Manual Manual 820 0043 Rev N 11 25 2019 40 Plumbing Diagram ...
Страница 42: ...Kodiak Recirculating Chiller Technical Manual Manual 820 0043 Rev N 11 25 2019 41 Refrigeration Diagram ...