background image

- 9 - 

General Features 

The EQUIPE 1200 & 2400 Packs have been designed to produce the most compact, 

versatile and easy to use flash source available today.  Features include: 

z

  Two independent Channels, each with two Flash Head sockets, having their own 

‘FLASH’ Variator, Modelling ‘LAMP’ Variator and Modelling ‘LAMP’ Control switch. 

z

  An ‘ISOLATE’ mode which provides the two independently controlled Channels 

with half the total flash capacity of the Pack available from either or both sockets in 
a particular Channel. 

z

  A ‘COMBINE’ mode which provides the total flash capacity of the Pack from ANY 

single socket or combination of sockets with a single set of controls. 

z

  Modelling ‘LAMP’ Variator and Modelling ‘LAMP’ Controls independent of Flash 

controls. 

z

  Digital ‘POWER’ display of the selected total Pack flash capacity and a visible 

‘READY’ indication. 

z

  Built in, sensitive ‘SLAVE’ Photocell with ON/OFF switch. 

z

  AUDIBLE ‘READY’ Sounder with ON/OFF switch to give audible indication of 

when the Pack is ready to fire. 

z

  A built in fan on the EQUIPE 2400 Pack which automatically switches in to cool 

the unit during periods of heavy use. 

z

  Overheat protection which protects the unit in the event of extended periods of 

continuous flashing and also in the unlikely event of failure of the cooling fan. 

z

  EMC (Electro-Magnetic Compatibility) filters fitted. 

z

  Special Adapters available to allow certain QUAD heads and accessories to be 

used with the EQUIPE 1200 & 2400 Packs. 

Power Supply Connection 

z

  The Packs are designed to operate on an alternating current (AC) supply of 200 to 

253 Volts, 50 Hz.  The Packs must NEVER be connected to any direct current 
(DC) supply. 

z

  The Packs conform to current standards which require connection to a properly 

grounded power supply.  The 3 core power cord supplied with each Pack will be 
colour coded as follows: 

 Live 

(L): 

 Brown 

 Neutral 

(N): 

 Blue 

 Earth 

(E): 

 Green/Yellow 

z

  It is essential that all 3 wires are connected to the correct plug pins in accordance 

with the above colour code and that the cable is securely clamped in the supply 
plug. 

AC Power Switch 

z

  The AC Power switch connects power to both the flash and modelling circuits. 

The switch is illuminated green when ‘ON’. 

z

  ALWAYS switch ‘OFF’ the unit before plugging or unplugging Flash Heads, 

changing fuses or modelling lamps. 

Содержание BW-2800

Страница 1: ...EQUIPE 1200 2400 PACK OPERATING INSTRUCTIONS Covers Models BW 2800 BW 2810...

Страница 2: ...IA THE PROTECTIVE EARTH CONDUCTOR OF THE POWER CORD DO NOT REMOVE THE EQUIPMENT SCREWS OR COVERS NO USER SERVICEABLE PARTS INSIDE DANGEROUS VOLTAGES ARE PRESENT EVEN AFTER SWITCHING OFF THE PACK SHOUL...

Страница 3: ...R SUPPLY CONNECTION 9 AC POWER SWITCH 9 CIRCUIT PROTECTION 10 FAST SLOW CHARGE SWITCH EQUIPE 2400 PACK ONLY 10 FLASH HEADS 10 FLASH POWER SELECTION INDICATION 11 MODELLING LAMP OUTPUT CONTROL 11 OPEN...

Страница 4: ...4 Figure 1 EQUIPE 2400 Control Panel Layout...

Страница 5: ...igital POWER Display and visible READY Indicator 10 Channel A Modelling LAMP Power Variator 11 Channel B Modelling LAMP Power Variator 12 Channel A Modelling LAMP Switch CONTINUOUS OFF INTERMITTENT 13...

Страница 6: ...6 Figure 2 EQUIPE 1200 Control Panel Layout...

Страница 7: ...d visible READY Indicator 9 Channel A Modelling LAMP Power Variator 10 Channel B Modelling LAMP Power Variator 11 Channel A Modelling LAMP Switch CONTINUOUS OFF INTERMITTENT 12 Channel B Modelling LAM...

Страница 8: ...damaged cables Have them replaced as soon as possible NEVER attempt to repair them yourself z NEVER use the Pack or Flash Heads in an environment where moisture water vapour or inflammable liquids vap...

Страница 9: ...ch automatically switches in to cool the unit during periods of heavy use z Overheat protection which protects the unit in the event of extended periods of continuous flashing and also in the unlikely...

Страница 10: ...or ease of identification the connectors at each end are identified with colour coded dots WHITE for the Pack and GREEN for the head z To fit a Flash Head first ensure the Pack is switched off and dis...

Страница 11: ...be controlled by the Channel A FLASH variator which provides a continuous adjustment over a 3 f stop range The maximum output set by the POWER switch is available from ANY socket z The total control r...

Страница 12: ...or LED will be lit and the Lamp s brightness can be continuously adjusted over a 3 f stop range using the LAMP variator for that Channel Open Flash z Press the OPEN FLASH button to test the flash oper...

Страница 13: ...e top panel Circuit Breaker has operated Pack previously under very heavy use with fast recycling and hot In this condition the Circuit Breaker button will project from the panel and may be manually r...

Страница 14: ...70 second 1 1660 second 1 570 second 1 1450 second 1 1700 second 1 2250 second SUPPLY VOLTAGE 200 to 253 Volts 50Hz 200 to 253 Volts 50Hz FLASH VOLTAGE STABILISATION 1 1 RECYCLE TIMES To 80 with 253V...

Страница 15: ...include a full range of Stands Umbrellas Reflectors and Register Wafers etc For details of all related products please contact your local distributor Due to our policy of constant product improvement...

Страница 16: ...0W s 3 800W s 800W s 800W s 4 600W s 600W s 600W s 600W s ISOLATE MODE The TOTAL flash output is split asymmetrically between the two Channels dependent upon the POWER switch VARIATOR A and VARIATOR B...

Страница 17: ...400W s 3 400W s 400W s 400W s 4 300W s 300W s 300W s 300W s ISOLATE MODE The TOTAL flash output is split asymmetrically between the two Channels dependent upon the POWER switch VARIATOR A and VARIATOR...

Страница 18: ...18 EQUIPE 1200 2400 INSTRUCTIONS BWL 0230 1 25 9 96 BOWENS INTERNATIONAL LIMITED 355 OLD ROAD CLACTON ON SEA ESSEX CO15 3RH ENGLAND Tel 44 0 1255 422807 Fax 44 0 1255 436342...

Отзывы: