background image

27

4.5 | 

ASSIGNING THE FOOT SWITCH

It is possible to connect a double foot switch and / or a
single foot switch with a switch. The switch allows changing 
between the foot switch levels.
- Press the setting for the respective socket.
- Call up the selection menu for the foot switch.
- Select the desired foot switch by pressing the 

corresponding button. 

- Confirm your selection with “OK”.
- The foot switch can be used to change between the 

foot switch levels. Press the orange switch and change 
the socket.

The activation is visualized by the coloring.

Foot switch 

ACTIVE 

Foot switch 

DEACTIVATED

Foot switch 

INACTIVE

Changeover from 
active to inactive 
possible.

Switch

Same method as for 
single foot switch.

The foot switch is assigned for the 
complete socket.

1. USING THE ARC 350

 | 

2. DISPLAY AND CONTROL ELEMENTS

 | 

3. START-UP

 |

4. OPERATION

 |

5. DISINFECTION AND CLEANING

 |

6. TECHNICAL DATA

Содержание ARC 350

Страница 1: ...Quick guide...

Страница 2: ...s quick guide is a brief summary of the most important working steps and information It does not replace the instructions for use For detailed information please read the instructions for use for the...

Страница 3: ...ts 8 2 3 Back of the generator 10 3 Start up 3 1 Switching on the device 11 3 2 Monopolar mode 12 3 3 Bipolar mode 13 3 4 Plug Cut COMFORT 14 3 5 Selecting the neutral electrode 15 4 Operation 4 1 Ope...

Страница 4: ...aecology Hand surgery ENT Cardiac surgery including open heart surgery Neurosurgery Pediatric surgery Plastic surgery dermatology Thoracic surgery Orthopedics Urology including transurethral resection...

Страница 5: ...ot switch Instruments monopolar and bipolar connecting cable Neutral electrode for monopolar applications With cable holder 1 USING THE ARC 350 2 DISPLAY AND CONTROL ELEMENTS 3 START UP 4 OPERATION 5...

Страница 6: ...vation indicator 3 Monopolar Effect button 4 Monopolar Maximum output power button 5 Monopolar sockets 6 Neutral electrode connection 1 USING THE ARC 350 2 DISPLAY AND CONTROL ELEMENTS 3 START UP 4 OP...

Страница 7: ...indicator 8 Bipolar Maximum output power button 9 Bipolar Effect button 10 Bipolar sockets 5 1 USING THE ARC 350 2 DISPLAY AND CONTROL ELEMENTS 3 START UP 4 OPERATION 5 DISINFECTION AND CLEANING 6 TE...

Страница 8: ...ar sockets Neutral electrode connection International 3 pin international Erbe 5 mm Bovie 4 mm socket Depending on configuration 1 USING THE ARC 350 2 DISPLAY AND CONTROL ELEMENTS 3 START UP 4 OPERATI...

Страница 9: ...ion 2 pin international 28 58 mm 2 pin international 28 58 mm Erbe VIO ICC Depending on configuration 1 USING THE ARC 350 2 DISPLAY AND CONTROL ELEMENTS 3 START UP 4 OPERATION 5 DISINFECTION AND CLEAN...

Страница 10: ...5 Fiber optic cable signal input socket 6 Fiber optic cable signal output socket 7 Ethernet connection 8 Mains power switch The following connections should only be used by service technicians and fo...

Страница 11: ...est The main display screen appears A message appears explaining how to operate the device The ARC 350 is ready for operation The parameters of the last saved program are shown on the display 3 1 SWIT...

Страница 12: ...electrode handpiece up to one of the two monopolar sockets 3 2 MONOPOLAR APPLICATION The foot switch must be connected when instruments without a finger switch are used 1 USING THE ARC 350 2 DISPLAY A...

Страница 13: ...ith a bipolar connecting cable into one of the two bipolar sockets Connect the foot switch 3 3 BIPOLAR APPLICATION 1 USING THE ARC 350 2 DISPLAY AND CONTROL ELEMENTS 3 START UP 4 OPERATION 5 DISINFECT...

Страница 14: ...vailable in monopolar and bipolar versions BOWA COMFORT function is available for BOWA COMFORT instruments with adjustable parameters Preset values are available and can be individually adjusted BOWA...

Страница 15: ...er conductivity in the direction of the fibrils EASY For monitoring of split neutral electrodes BABY For monitoring of split pediatric electrodes MONO For selection of one piece neutral electrodes 2 3...

Страница 16: ...up white The indicator starts to flash when settings are changed 2 Effect The effect of the electrosurgical dissection or coagulation can be set using the Effect button 3 Max Watt Press max Watt to ad...

Страница 17: ...ontact 10 Programs Calling up of stored program selection 11 The bipolar activation indicator lights up yellow or blue as soon as an instrument is activated in the respective socket If an instrument i...

Страница 18: ...ndicator lights up white When the active socket is used the current type is displayed in the activation indicator in blue and yellow 2 Unused socket If there is no instrument connected to the socket o...

Страница 19: ...to enter the mode selection directly Monopolar cutting modes NAME APPLICATION SUITABLE INSTRUMENT Standard Cutting with low electrical tissue resistance Cutting or preparation of fine structures Needl...

Страница 20: ...Dynamic pulse sequence for practiced users Polypectomy snares GastroLOOP 3G Removal of polyps with polypectomy snares via flexible endoscopes Dynamic pulse sequence for seasoned users Polypectomy sna...

Страница 21: ...ndency Knife electrodes Spatula electrodes Needle electrodes Spray Coagulation of diffuse bleeding Ball electrodes Knife electrodes Spatula electrodes Needle electrodes Laparoscopy Laparoscopy Arthros...

Страница 22: ...Vaporization of prostate tissue TUR VAP Resectoscope monopolar Resection snare Rollerblade electrode Cardiac Mammary Breast surgery Cardiac surgery Knife electrodes Cardiac Thorax Thoracic surgery Kni...

Страница 23: ...bipolar Resection snare Bipolar scissors Dissection Coagulation and cutting of tissue Bipolar scissors VaporizationR Hysteroscopy Transurethral resection of the prostate TURP Transurethral resection o...

Страница 24: ...ipolar vessel sealing open and laparoscopic TissueSeal PLUS NightKNIFE LIGATOR ERGO 310D ERGO 315R ARCSealL Bipolar vessel sealing open and laparoscopic ERGO 310D ERGO 315R TissueSeal PLUSL Vessel sea...

Страница 25: ...zationR Hysteroscopy Transurethral resection of the prostate TURP Transurethral resection of the bladder TURB Vaporization of prostate tissue TUR VAP Resectoscope Rollerblade electrode Vaporization el...

Страница 26: ...m power Set the power in individual steps using the and buttons Press OK to confirm your selection Press any key outside the selection field to return to the main screen without changing the selection...

Страница 27: ...ding button Confirm your selection with OK The foot switch can be used to change between the foot switch levels Press the orange switch and change the socket The activation is visualized by the colori...

Страница 28: ...infectant approved by the manufacturer for surface cleaning Cleaning agents and disinfectants Wipe with a sponge or cloth moistened with clean water Dry with a clean lint free cloth 1 2 3 Make sure th...

Страница 29: ...75 mm Weight 12 5 kg Classification according to EU Directive 93 42 EEC IIb Protection class according to EN 60601 1 I Type of applied part according to EN 60601 1 CF CE mark as per EU Directive 93 42...

Страница 30: ...30...

Страница 31: ...31...

Страница 32: ...e reserve the right to make technical and structural amendments Copyright of BOWA electronic Gomaringen BOWA electronic GmbH Co KG Heinrich Hertz Strasse 4 10 72810 Gomaringen I Germany Phone 49 0 707...

Отзывы: