background image

    Startup Sequence      3 

Term during the setup navigation. Once the adapter is setup 
and running, you can change the terminal’s and host’s 
emulation back to 

PC-Term.

 

Startup Sequence 

When the terminal is turned on, it performs an initial adapter 
diagnostic test and displays a message indicating the result of 
that test.  

◊ 

Ethernet pass

 indicates that the test was successful and the 

card is functioning properly. 

◊ 

Ethernet check xxh

 means that the diagnostic test has failed 

(see table labeled 

Diagnostic Results

 below). 

◊ 

The Ethernet check may also be followed by the message  

FATAL ERROR. MAC address failure, contact technical support. 

This 

message indicates that the card’s MAC address has been 
corrupted beyond software recovery. Record all error 
information and contact your Technical Support 
Department for assistance (see the inside of the back cover 
for details).  

 

The adapter will continue to operate after these error 
messages, however there is no guarantee that the unit will be 
able to connect to a host. 
If the EEPROM checksum fails, all IP addresses are set to 

0.0.0.0

Poweron Connect 

to

 No

, and 

Comm Protocol

 to 

Both

 

Diagnostic Results 

Check 01h

 

RAM problem 

Check 09h

 

MAC and RAM problem 

Check 02h

 

ROM problem 

Check 0Ah

 

MAC and ROM problem 

Check 03h

 

RAM and ROM problem 

Check 0Bh

 

MAC, RAM and ROM problem 

Check 04h

 

NVRAM problem 

 

Check 0Ch

 

MAC and NVRAM problem 

Содержание Ethernet Interface Adapter

Страница 1: ...Ethernet Interface Adapter User s Guide...

Страница 2: ...Boundless Technologies Inc to improve products as new technology components software and firmware become available Boundless Technologies therefore reserves the right to change specifications without...

Страница 3: ...E r r o r N o t e x t o f s p e c i f i e d s t y l e i n d o c u m e n t E r r o r N o t e x t o f s p e c i f i e d s t y l e i n d o c u m e n t iii All rights reserved Printed in USA...

Страница 4: ...nterface Main Menu 4 Configuring the Ethernet Interface 5 Edit Host IP Address 6 Edit Local IP Address 7 Edit Subnet Mask 8 Edit Default Gateway 8 Poweron Connect 8 Comm Protocol 9 Recall Saved Settin...

Страница 5: ...pter provides the text terminal with a single Telnet session Telnet is an application providing terminal emulation connectivity for logging on to a remote system TCP IP NT SERVER TCP IP UNIX SERVER PI...

Страница 6: ...adapter s Comm Protocol is set to None the terminal could lose data Emulation This adapter works with all the standard terminal emulations However the host emulation should match the terminal emulati...

Страница 7: ...AC address failure contact technical support This message indicates that the card s MAC address has been corrupted beyond software recovery Record all error information and contact your Technical Supp...

Страница 8: ...conclusion of the startup diagnostics you can press any key to enter the setup menu Note that the Main Menu is accessible only when the terminal is disconnected from the host If the Poweron Connect mo...

Страница 9: ...key to activate the Main Menu Configuring the Ethernet Interface The procedures detailed in the following sections require some site specific configuration information that must be supplied by your l...

Страница 10: ...Host IP Address To define your host IP address select option number 1 When prompted enter the host s IP address in dotted decimal format as shown in the following example Enter Host IP address 175 55...

Страница 11: ...the address again For example Enter Host IP address 175 55 Invalid entry Format Enter Your Choice Host IP address Edit Local IP Address To define your terminal IP address select option number 2 When...

Страница 12: ...ose destination address cannot be found on the local network is sent to the IP address of the default gateway for routing to other networks To set the default gateway address for your terminal select...

Страница 13: ...stored in NVRAM Message Recall complete indicates a successful recall Save Settings for Powerup When all of the terminal s Ethernet settings are acceptable select option number 8from the Setup Menu t...

Страница 14: ...onnect command in intervals of 5 10 20 40 80 and 160 seconds If still unsuccessful the Ethernet interface will stop trying and display the message Connection Failed to followed by the host IP address...

Страница 15: ...mation pertaining to the adapter HARDWARE INFORMATION Physical Address XX XX XX XX XX XX Code Revision X XX Part Number 589 XXXXXXX Code Checksum XXXXXX Diagnostic Results Pass Check XX Link Integrity...

Страница 16: ...these values will start from 0 These counters will role over to 0 if they reach 15 Deferred Transmits Incremented by one for each collision retry or after multiple transmit deferrals Excess deferred...

Страница 17: ...e contact the Boundless Technologies Technical Support Department directly You will be required to provide the name of your distributor and a description of the problem as described above Please refer...

Страница 18: ...100 Marcus Boulevard 598 00112716...

Отзывы: