background image

6  

STEP-BY-STEP

 GUIDE

0800 003 006

   

/

   

boundaryline.co.nz

TECHNICAL DRAWINGS

SMARTWALL VERTICAL

10:1

A

Terranota Ltd. P.O. Box 1703 Invercargill 1703
Telephone: 0800 003 006
Email: [email protected]
Website: www.boundaryline.co.nz

MODEL

SMARTWALL 1800

VERTICAL

Issue Date

18-04-2019

scale

1:16

Unless Otherwise specified

All units in Millimeters
Linear Tol/- 0.5mm overall
Angular Tol/- 0.5mm overall

Revision

Patent Pending NZ Pat. App. 745289/753226

POST CAP

POST

TOP RAIL

CLT LAMINATED PALING

28.0

A

A

'GOOD GROUND' 100KPA

ALLOWABLE BEARING AS

DEFINED BY NZS

 3604

SLOPE TOP OF
CONCRETE TO ALLOW
WATER TO DRAIN
AWAY FROM POST

CONCRETE 17.5MPA MIN

250.0mm

100.0

B

B

A

B-B

A-A

B

1800.0

10:1

B

15.0

15.0

275.0

28.0

SCREW

CLT LAMINATED PALING

TOP RAIL

POST CAPS

POST

2250.0

POST CENTRE

2400.0

Содержание SMARTWALL

Страница 1: ...STEP BY STEP GUIDE INSTALL GUIDE SMARTWALL A STEP BY STEP GUIDE TO INSTALLING YOUR FENCE...

Страница 2: ...ART READTHIS TOOLS LIST It is recommended that the reader pays particular attention to those items identified as IMPORTANT in this manual to ensure satisfactory long term performance IMPORTANT the tab...

Страница 3: ...STALLING POSTS a Fastening posts together b Fixing post in ground If it isn t possible to fix posts as proposed here please contact us for further information IMPORTANT Approx 40mm 2 Fasteners approx...

Страница 4: ...l A rubber mallet can be used if required Continue to insert all palings ensuring the tongue and groove joint is in place correctly Once all palings are installed it is time to fit your top rail Slide...

Страница 5: ...ay particular attention to the area under the top rail which is sheltered from natural washing by rain 2 DO NOT build up soil garden fill and or dirt against the bottom rails and posts of your fence a...

Страница 6: ...ess Otherwise specified All units in Millimeters Linear Tolerance 0 5mm overall Angular Tolerance 0 5mm overall Revision Patent Pending NZ Pat App 745289 753226 POST CAP POST TOP RAIL CLT LAMINATED PA...

Страница 7: ...rwise specified All units in Millimeters Linear Tolerance 0 5mm overall Angular Tolerance 0 5mm overall Revision Patent Pending NZ Pat App 745289 753226 GOOD GROUND 100KPA ALLOWABLE BEARING AS DEFINED...

Страница 8: ...s including the number of surrounding properties and how exposed the location is If your property is exposed to higher wind speeds please contact us for further advice recommendations Also if in proxi...

Отзывы:

Похожие инструкции для SMARTWALL