background image

3  

0800 003 006

   

/

   

boundaryline.co.nz

A STEP-BY-STEP GUIDE

 TO INSTALLATION

STEP 1 – 

MARKING OUT POST HOLES

  Post lengths required will increase accordingly to cater for these ground conditions.

Soil Type

Minimum Hole Depth

Approximate Concrete Required

Clay/Firm Earth

600mm

2 bag per hole (20Kg bags)

Sand/Loose Fill

900mm

3 bag per hole (20Kg bags)

!

IMPORTANT

Start post may 

be existing 

or temporary 

peg

Dig holes 

according to 

depth chart 

below

All holes should be 

straight (i.e. Sides 

parallel or wider at 

the bottom than the 

top

Diameter of all holes 

is 

250mm

 minimum.

Marker pegs

Mar

k out

 post

 cen

tres

STEP 2 – 

INSTALLING POSTS

a. Fastening posts together 

b. Fixing post in ground

If it isn’t possible to fix posts as 

proposed here, please contact 

us for further information. 

!

IMPORTANT

Approx. 

40mm

2 Fasteners approx. 

60mm from top of 

post 

Maximum screw spacing 

300mm centres

10 - 16 x 16mm 

self-drilling screw 

placings.
Screws to conform to 

AS3566 Class 3.

Place first post in hole

-

 Adjust to correct height

-

 Support post with temporary brace

-

 Fill hole with fully mixed, wet concrete

-

 Vibrate and compact the concrete to remove voids.

Align vertically with 

spirit level in both 

directions 

Do not allow soil, 

garden fill and/or dirt 

to come in contact with 

posts as this may cause 

the post to corrode

Slop top of 

concrete away 

from post (to drain 

away water)

Bottom 

rail approx. 

50mm 

above 

ground

Nominal  

30mm

1800mm = 1830mm

Содержание SMARTWALL

Страница 1: ...STEP BY STEP GUIDE INSTALL GUIDE SMARTWALL A STEP BY STEP GUIDE TO INSTALLING YOUR FENCE...

Страница 2: ...ART READTHIS TOOLS LIST It is recommended that the reader pays particular attention to those items identified as IMPORTANT in this manual to ensure satisfactory long term performance IMPORTANT the tab...

Страница 3: ...STALLING POSTS a Fastening posts together b Fixing post in ground If it isn t possible to fix posts as proposed here please contact us for further information IMPORTANT Approx 40mm 2 Fasteners approx...

Страница 4: ...l A rubber mallet can be used if required Continue to insert all palings ensuring the tongue and groove joint is in place correctly Once all palings are installed it is time to fit your top rail Slide...

Страница 5: ...ay particular attention to the area under the top rail which is sheltered from natural washing by rain 2 DO NOT build up soil garden fill and or dirt against the bottom rails and posts of your fence a...

Страница 6: ...ess Otherwise specified All units in Millimeters Linear Tolerance 0 5mm overall Angular Tolerance 0 5mm overall Revision Patent Pending NZ Pat App 745289 753226 POST CAP POST TOP RAIL CLT LAMINATED PA...

Страница 7: ...rwise specified All units in Millimeters Linear Tolerance 0 5mm overall Angular Tolerance 0 5mm overall Revision Patent Pending NZ Pat App 745289 753226 GOOD GROUND 100KPA ALLOWABLE BEARING AS DEFINED...

Страница 8: ...s including the number of surrounding properties and how exposed the location is If your property is exposed to higher wind speeds please contact us for further advice recommendations Also if in proxi...

Отзывы: