background image

36776-0-0716

Page 17

FIREPLACE DIMENSIONS

INDEX 

LETTER

DIMENSION DESCRIPTION

VFLL60FP

VFLL72FP

Dimensions in Inches

A

The maximum height of firebox face (excluding standoffs)

22-1/4

22-1/4

B

The maximum width of the firebox face (excluding nailing flanges)

64-3/4

76-3/4

C

The maximum depth of the firebox

11-1/4

11-1/4

D

The height of the firebox opening

12-1/8

12-1/8

E

The width of the firebox opening

60

72

F

The interior depth of the firebox (not shown)

10-1/2

10-1/2

G

The rear exterior width of the firebox (not shown)

64-3/4

76-3/4

H

The height to the firebox standoffs

18-15/16

12-15/16

K

Height from the bottom of the firebox to the gas line opening

1-5/8

1-5/8

L

Depth from the front of the firebox to gas line opening

4-5/16

4-5/16

M

Depth from rear of firebox to gas line opening

6-7/8

6-7/8

N

Glass height (not shown)

8

8

O

Glass width (not shown)

61-3/8

73-3/8

Q

Distance from fireplace bottom to fireplace opening

7-1/2

7-1/2

S

Overall height to header

41-1/8

41-1/8

T

Opening Lip

1/2

1/2

S

C

GAS LINE

ACCESS

T

Q

C

K

A

H

HOLES IN

STANDOFF

E

D

M

L

GAS LINE

ACCESS

ELECTRICAL

ACCESS

B

G

Содержание VFLL60FP72LN-1

Страница 1: ...ids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately ca...

Страница 2: ...ean Face Flush Mount 30 Installation Option 2 Flush Mount 26 Framing Flush Mount 27 Nailing Flanges Mounting Brackets Flush Mount 28 Fireplace Non Combustible Board Installation Flush Mount 29 Complet...

Страница 3: ...undle in an out of the way place to avoid damaging the components 6 Lift the fireplace off the pallet and place it near the installation site If the fireplace must be placed on end so that a hand truc...

Страница 4: ...on Guidelines Determine where to install the fireplace The fireplace can be mounted on any of these surfaces 1 A flat hard combustible or non combustible surface 2 A raised platform of combustible or...

Страница 5: ...11 AAA Battery 3 12 Hardware Pack 1 13 AC Adaptor 1 14 Wall Mounted Control Box 1 15 Remote Receiver 1 16 Battery Pack 1 17 Button Switch 2 18 Mounting Bracket 1 19 Wall Plate 1 20 Optional Inner Top...

Страница 6: ...lling Drywall Screw 9 Nailing Flange 4 See Parts Lists on page 46 47 for ordering replacement parts Do not order batteries bolts screws washers or nuts They are standard hardware items and can be purc...

Страница 7: ...h may cause soot 6 Do not place glass media on burner or burner ports The glass media should only be placed on the fireplace floor 7 Do not use rock wool embers or lava rock 9 Annual inspection and cl...

Страница 8: ...ir Shutter Opening VFLL60FP90 1 4 inch VFLL72FP90 1 4 inch VFLL60FP90LP VFLL60FP90LN VFLL72FP90LP VFLL72FP90LN Input BTU HR Maximum 38 500 40 000 38 500 40 000 Input BTU HR Minimum 31 000 25 000 31 00...

Страница 9: ...ace media material on or next to the burner Part Number Description VFLL60 VFLL72 DFL601BL DFL721BL Decorative Front Beveled 1 inch Black DFL602BL DFL722BL Decorative Front Beveled 2 inch Black DFL602...

Страница 10: ...t the rate of 4 percent for each 1 000 feet 305m above sea level Contact the manufacturer or your gas company before changing spud orifice size Well Head Gas Installations Some natural gas utilities u...

Страница 11: ...test Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750C are considered non combustible Install the fireplace out of household traffic and away from furniture and draper...

Страница 12: ...nt women persons with heart or lung disease anemia those under the influence of alcohol those at high altitudes are more affected by carbon monoxide than others DANGER The installer of this product is...

Страница 13: ...caped gas can adsorb or absorb onto or into walls masonry and other materials and fabrics in a room That will take some of the odorant out of the gas reducing its odor intensity LP Gas may stratify in...

Страница 14: ...ice isn t centered in the venturi inlet and or is not aligned with the venturi Any misalignment of the burner orifice may be corrected by bending the shutter cap holding the orifice to the inlet of th...

Страница 15: ...e Ventilation Air From Outdoors page 16 Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in whi...

Страница 16: ...oor into adjoining room see option 3 Figure 7 Each ventilation grill or opening shall have a minimum free area of one square inch per 1 000 BTU HR of the total input rating of the gas equipment in the...

Страница 17: ...ot shown 10 1 2 10 1 2 G The rear exterior width of the firebox not shown 64 3 4 76 3 4 H The height to the firebox standoffs 18 15 16 12 15 16 K Height from the bottom of the firebox to the gas line...

Страница 18: ...10 Figure 10 Junction Box Wiring Installation A factory installed junction box is located at the lower left corner inside the firebox bottom cavity The suggested 120V electrical requirements include...

Страница 19: ...e black wires with a wire nut and the white wires with a wire nut Secure the incoming ground wire and green receptacle ground wires under the green ground screw provided in the junction box Re install...

Страница 20: ...for leaks on all exposed connections should be done with leak test solution or a soap solution After testing is complete all solution should be cleaned off On unexposed connections a pressure test sho...

Страница 21: ...non combustible board and outside of the fireplace boundaries Notice Non combustible material provided with the fireplace is larger than required for this installation Material may be trimmed to the...

Страница 22: ...he installation steps on pages 23 25 are for Installation Option 1 Clean Face See pages 26 29 for installing the fireplace for Installation Option 2 Flush Mount This type of installation will allow fo...

Страница 23: ...ails on electrical requirements 3 Verify gas and electrical lines are ready for fireplace installation See Gas Supply page 20 TABLE 3 FRAMING DIMENSIONS in inches FOR FIGURES 23 25 Model A B C D E F V...

Страница 24: ...ble board flush to the fireplace face top side and bottom Finishing Option 2 See Figures 24 to 27 TOPOF FIREPLACE FIREPLACE OPENING FOR USE WITH HI TEMP PAINTED NON COMBUSTIBLE BOARDS TO OPENING Figur...

Страница 25: ...on Combustible Board See Figure 28 Do not attach non combustible board to the fireplace Attach non combustible board only to side studs standoffs and header board Predrill holes into non combustible b...

Страница 26: ...for Installation Option 2 Flush Mount See pages 22 25 for installing the fireplace for Installation Option 1 Clean Face This type of installation will allow you to apply tile marble stone or other non...

Страница 27: ...ure 32 Rough Opening for Installing in Corner 1 Frame in rough opening Use dimensions shown in Figure 30 for a conventional rough opening Use Figure 31 for an elevated installation Provide support to...

Страница 28: ...oard flush to the fireplace face top side and bottom Finishing Option 2 See Figures 33 38 TOPOF FIREPLACE FIREPLACE OPENING NON COMBUSTIBLE BOARD ON TOP OF FIREPLACE WITH NON COMBUSTIBLE TILE ETC TO O...

Страница 29: ...Install Non Combustible Board See Figure 39 Do not attach non combustible board to the fireplace Attach non combustible board only to side studs standoffs and header board Predrill hole s into non co...

Страница 30: ...ng instructions provided Verify remote is communicating with receiver 8 Replace LED reflector 9 Retrieve shorter glass and install in front of burner 10 If installing an optional liner install them no...

Страница 31: ...the front of the inner top deflector should point downward Tighten the five 5 Phillips head screws to lock in place Figure 46 16 Retrieve larger glass and install in slots on the left and right of fi...

Страница 32: ...eplaced it must be replaced with equivalent gauge and temperature rated wire CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous opera...

Страница 33: ...0 0716 Page 33 LED WIRING Figure 48 YELLOW RED BLACK BLACK BLACK RED BLACK LED STRIP LED STRIP TRANSFORMER CONTROL MODULE BLACK BLACK BLACK LEFT BUTTON BRIGHTNESS RIGHT BUTTON MODE JUNCTION BOX LED S...

Страница 34: ...arious colors and package sizes Choose the size appropriate for your fireplace See list on page 9 CAUTION To prevent injury use gloves and eye protection while applying the decorative glass or droplet...

Страница 35: ...right side into the slots in the firebox Carefully angle in the left side of the glass and then slide the glass to the left Settle the glass into the slots by gently lowering it See Figures 53 58 DECO...

Страница 36: ...ote control Refer to remote instructions for detailed operation information FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result...

Страница 37: ...flame sensor to cool When the flame sensor cools the fireplace will shut down Correct Pilot Flame Pattern Figure 54 PILOT FLAME CHARACTERISTICS Incorrect Pilot Flame Pattern Figure 55 If pilot flame p...

Страница 38: ...on layout and informative LCD display Figure 56 The Transmitter is powered by 3 AAA type batteries A Mode Button is provided to Index between the features and a Thermostat Button is used to turn on of...

Страница 39: ...LOT UP CPI CONTINUOUS PILOT DOWN SPARK ROD GROUND 9 PIN CONNECTOR PILOT SENSOR STEPPER MOTOR REGULATOR GAS VALVE OUTLET PRESSURE TAP INLET PRESSURE TAP SENSOR DFC ELECTRONIC CONTROL MODULE IPI CPI PIL...

Страница 40: ...epletion Sensor Pilot When the pilot has a large yellow tip flame clean the Oxygen Depletion Sensor as follows 1 Use canned air to blow through hole A See Figure 60 This will blow out foreign material...

Страница 41: ...0 inches w c at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11 0 inches w c for the purpose of input adjustment to a maximum of 13 0 inches w c A...

Страница 42: ...ify that the power supply AC DC adapter is present and that the batteries inside the receiver and or optional battery pack are fresh and installed with correct polarity Make sure all the connections b...

Страница 43: ...ce page 39 Pilot not grounded well Check ground connections Sensor Wire loose Check sensor wire terminals Gas pressure incorrect Adjust gas pressure Pilot Gas Line bent or kinked Replace pilot tube Fa...

Страница 44: ...y pressure Blocked orifice Check orifice opening Clogged or dirty burner ports Clean burner ports Faulty valve Replace valve High altitude Adjust orifice size for altitude Backfire of burner Blocked o...

Страница 45: ...36776 0 0716 Page 45...

Страница 46: ...th these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury 5 5 8 12 11 10 7 9 1 32 34 37 25 38 27 26 33 28 30 31 29 35 BURNE...

Страница 47: ...3 36803 Burner Box Back 28 36771 36771 Pilot Tube Assembly LP Only 29 36770 36770 Pilot Regulator Tube Assembly NAT Only 30 36769 36769 Valve Regulator Tube Assembly NAT Only 31 R7063 R7063 Regulator...

Страница 48: ...be ordered by your Service Person or Dealer Proof of purchase is required for warranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number an...

Страница 49: ...fireplace insert Contact your Empire dealer for more information FOR THE HOMEOWNER CONTEMPORARY LINEAR VENT FREE GAS FIREPLACE ModELS VFLL60fp90l n p 1 VFLL72FP90L N P 1 HOMEOWNER REFERENCE INFORMATIO...

Страница 50: ...off the fireplace and let it cool completely before servicing or touching any buttons on the TV Maintenance and Service Although the frequency of servicing and maintenance will depend on use and the t...

Страница 51: ...lots See Figures B TOP VIEW GLASS Figure B Replacing the Glass Front 1 Place the right side of the glass into the slots in the firebox Carefully angle in the left side of the glass and then slide the...

Страница 52: ...lass from the accessories listed on page 9 1 Apply the crushed glass to the shaded area only See Figure D Use enough to cover the floor of the fireplace but do not allow the media to reach higher than...

Страница 53: ...ote control Refer to remote instructions for detailed operation information FOR YOUR SAFETY READ BEFORE LIGHTING Warning If you do not follow these instructions exactly a fire or explosion may result...

Страница 54: ...SELECTOR SWITCH IPI INTERMITANT PILOT UP CPI CONTINUOUS PILOT DOWN SPARK ROD GROUND 9 PIN CONNECTOR PILOT SENSOR STEPPER MOTOR REGULATOR GAS VALVE OUTLET PRESSURE TAP INLET PRESSURE TAP SENSOR DFC EL...

Страница 55: ...n Press the Mode Button to adjust LED light system from Automatic Color Changes to Individual Colors 1 Auto cycle Rapid 2 Auto cycle Gradual 3 Pause Auto cycle 4 Deep Blue 5 Royal Violet 6 Cardinal Re...

Страница 56: ...g manual bypass of the remote system WARNING Property Damage Hazard Excessive heat can cause property damage The fireplace can stay lit for many hours Turn off the fireplace if it is not going to be a...

Страница 57: ...now initialized Temperature Indication Display With the system in the OFF position press the Thermostat Button and the Mode Button at the same time Look at the LCD screen on the Transmitter to verify...

Страница 58: ...ll reduce the flame height by one step until the flame is turned off The Up Arrow Button will increase the flame height each time it is pressed If the Up Arrow Button is pressed while the system is on...

Страница 59: ...n of the Transmitter SET TEMPERATURE ROOM TEMPERATURE Figure Q Figure R USING THE REMOTE CONTROL Smart Thermostat Transmitter Operation The Smart Thermostat function adjusts the flame height in accord...

Страница 60: ...f the Receiver batteries depends on various factors quality of the batteries used the number of ignitions of the fireplace the number of changes to the room thermostat set point etc When the Receiver...

Страница 61: ...te control thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option WARRANTY Duties Of The Ow...

Страница 62: ...mpire Comfort Systems Inc Belleville IL If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer...

Отзывы: