37754-0-0717
Page 12
MANTEL CHART
INDEX
LETTER
MANTEL DEPTH
(Dimensions in inches)
A
12
27
B
10
27
C
8-3/8
24-7/8
D
6-5/8
23-5/8
E
5
20-1/2
F
3-3/8
18-3/8
G
1-5/8
16-1/8
H
0
14
Figure 5
CLEARANCES
Minimum clearance from top of fireplace opening to ceiling is
38
inches.
Minimum clearance from side of fireplace opening to
adjacent sidewall is 6
inches
.
6” MIN.
(20cm)
CEILING
MEASURE
TO T
OP
OF
FIREPLACE OPENING
38”
MIN
(89cm)
Figure 6
CLEARANCES (INDOOR APPLICATION)
19” MIN.
2” X 4” HEADER
STAND-OFF
13” (76mm) HEIGHT
ABOVE TOP OF FIREPLACE
FINISHED WALL
(COMBUSTIBLE)
NON-COMBUSTIBLE
BOARD
TOP FRAMING LEDGE
BARRIER
SCREEN/GLASS
FRONT
NAILING FLANGE
NON-COMBUSTIBLE
BOARD
Figure 2
NOTICE:
Use only non-combustible materials to finish the face
of the fireplace.
NOTICE:
COMBUSTIBLE MATERIALS
ALLOWED IN SHADED AREA
Figure 3
Vent Pipe Clearance
NOTICE:
Maintain 1-inch clearance around vertical vent pipe.
See Figure 4
.
For horizontal vent, maintain a minimum 1-inch clearance
to the bottom and sides of the vent, and 3-inch clearance to
combustibles above the vent pipe.
1” MINIMUM CLEARANCE
AROUND VERTICAL VENT
PIPE (EXCLUDING HEADER
SHIELDS)
VENT PIPE
Figure 4