Model: BOT01-V3
Bottlelight Company Dr. Kitzenmaier
Gregor-Mendel-Str. 2
Tel.: +49 (0) 331 867 17 23
BOT01-V3_User Manual_2021 03 17_EN
14469 Potsdam/Germany
page 2
Bottle
Light
i.
Either you have in front of you a power adapter (7) without wires (left image above) or with wires (right image above).
ii.
Connect the blue or transparent-black wire of the Bottlelight cable (4) with the (
-
) pole of the power adapter (7) or with the
black cable (-) of the power adapter (7);
iii.
Connect the brown or transparent wire of the Bottlelight cable (4) with the (+) pole of the power adapter (7) or with the red
cable (+) of the power adapter (7);
iv.
Then, connect the input clamps of the power adapter (7) or the brown and blue input cables of the power adapter (7) to the
mains supply cables (brown and blue).
v.
Take care that the power adapter (7) has enough air cooling after the complete installation.
ATTENTION: The installation and connection to Mains Supply may only be carried out by an electrician and in accordance with
local safety regulations. Take also notice of the further information for installation at the ceiling, as mentioned below herein.
Connecting the Bottlelight mechanically and electrically to the ceiling
Pull the cable (4) through two neighboring holes of the three-hole
element (6), as shown in the drawing.
Then connect the three-hole element (6) at the hook at the ceiling.
Connect the two wires of the Bottlelight cable (4) to the output of
the power adapter (7) as shown in the drawing.
The brown or transparent wire of the cable (4) is (
+
)
The blue or black wire of the cable (4) is (
-
)
ATTENTION
: Only safety type SELV power adapters (7) are
allowed to be connected to the Bottlelight lamp.
The power adapter must have a current regulated
output 0
–
1000 mA DC (@5,5-6,5 V).
ATTENTION
:
Never connect any of the wires of the
Bottlelight cable (4) to mains supply!
6
4
Connecting the Power Adapter (7)
brown or trasparent
blue or black
black
red
brown
blue
brown
blue